Siemens 6SE7090-0XX84-4HA0 SIMOVERT MASTERDRIVES LBA Adaptador de Bus Local
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Utere LBA et ADB ut componentia separata cum functionibus diversis.
- Primum occupare positionem montandi 2 pro una tabula adaptationis.
- Servare interstitium C pro tabula encoderis.
- Sequere limites specificos hospitis pro combinationibus CBP et tabularum technicarum.
6SE7090-0XX84-4HA0 SIMOVERT MASTERDRIVES LBA Local Bus Adapter
An LBA local-bus adapter used with the ADB adaptation board to extend the option-board arrangement in compatible drive electronics boxes.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6SE7090-0XX84-4HA0 |
| Typus Producti | Local-bus adapter |
| Functio principalis | Connection of additional drive option positions |
| Applicatio | Compact and chassis drive electronics boxes |
Additional positions
The LBA supports the expansion arrangement for option slots D through G.
Separate ADB carrier
Miniature boards mount on the corresponding adaptation board.
Sequentia slot definita
Positio montandi 2 occupatur prima, cum tabula adaptativa unica utitur.
Product Overview
6SE7090-0XX84-4HA0 praebet connexionem bus-localem quae requiritur, cum positiones tabularum optionum additae in unitatibus SIMOVERT MASTERDRIVES compactis et chassibus compatibilibus utuntur. Cum portatore ADB correspondente operat, non eum substituit.
Dispositio cistae electronicae locat slotos D et E ad positionem montandi 2, et slotos F et G ad positionem montandi 3. Selectio tabularum et sequentia slotorum dependent ab unitate controlis hospitis et a quacumque tabula technologiae vel encoderis iam installata.
Key Functions
Coniungere positiones optionum expansas
Dispositio LBA et ADB permittit usum positionum optionum additarum D, E, F et G in cista electronica supportata.
Servare sequentiam tabularum requisitam
When only one adaptation board with options is installed, it occupies mounting position 2 on the right-hand side.
Coordinate communication and technology boards
With a technology board in mounting position 2, the adaptation board carrying the CBP is installed in mounting position 3.
Official Specifications
| Expanded option-slot arrangement | D and E at mounting position 2; F and G at mounting position 3 |
|---|---|
| Control-unit-side option positions | Slot A at the top and slot C at the bottom of the CU board |
| Backplane board accommodation | One CU control board and up to two ADB carrier boards |
| Option-board capacity per ADB carrier | Usque ad duo tabulata optionum minuta in singulo portatore ADB |
| Mechanical Retention | Insercio per clippaginem intra cistulam electronicam |
| Capacitas Substitutionis Calidae | Insertio et remocio tabularum tantum cum alimentatione electrica disiuncta |
| Ponderis netum | 0,1 kg |
| Substantia declarata secundum regulam REACH | Plumbum (CAS 7439-92-1) supra 0.1% per massam |
Quaestiones Frequenter Rogatae
Num opus est ADB separato quando tabulae optionum installantur per 6SE7090-0XX84-4HA0?
The expanded option arrangement requires both the LBA local-bus adapter and the corresponding ADB adaptation board.
Which option positions become available through 6SE7090-0XX84-4HA0?
The expanded compact and chassis electronics-box arrangement uses option slots D, E, F, and G.
Where should I place a single option carrier when using 6SE7090-0XX84-4HA0?
A single adaptation board with optional boards must occupy right-hand mounting position 2.
How should I arrange a CBP carrier and a technology board with 6SE7090-0XX84-4HA0?
The technology board occupies mounting position 2 and the adaptation board with CBP occupies mounting position 3.
Can the encoder board be moved away from slot C when 6SE7090-0XX84-4HA0 is fitted?
The encoder board still requires slot C.
Can a CBP use either position on an ADB with 6SE7090-0XX84-4HA0 in the supported Motion Control arrangement?
CBP potest occupare positionem ADB superiorem aut inferiorem in dispositione specificata Motion Control Performance 2, Motion Control et Vector Control.
Quid fieri debet antequam aperiam impulsum ad installandum 6SE7090-0XX84-4HA0?
Disiungere impulsum ab alimentatione et exspectare donec condensatores DC-link prorsus descaricentur antequam converterem aperias.