Siemens · SIMOVERT MASTERDRIVES Motion Control
6SE7090-0XX84-0AD1 SIMOVERT MASTERDRIVES MC CUMC Control Unit
The Siemens CUMC control unit is the Motion Control board used in compatible SIMOVERT MASTERDRIVES MC compact and chassis drive units.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6SE7090-0XX84-0AD1 |
| Typus Producti | CUMC motion-control board for compact and chassis drive units |
| Functio principalis | Executes drive control, motion-control functions, I/O processing and serial communication for compatible MASTERDRIVES MC units |
| Applicatio vel series compatibiles | SIMOVERT MASTERDRIVES MC compact and chassis converters using the CUMC control-unit generation |
Identificatio exacta.
Match the full article number and confirm that the installed drive uses the CUMC generation.
Parametri de Conducere
Faceti o copie de rezerva a intregului set de parametri de conducere, configuratie a placi si adrese de comunicare inainte de schimbare.
Atribuirea Conectorilor
Pastrati cablarea seriala X300 si X103 impreuna cu toate atribuirile terminalelor de comanda si ale placilor optionale.
Product Overview
The Siemens CUMC control unit is the Motion Control board used in compatible SIMOVERT MASTERDRIVES MC compact and chassis drive units.
Placa CUMC ofera arhitectura de control pentru generatia originala MASTERDRIVES MC compact si chassis. Conexiunile standard includ comunicarea de serviciu RS232 sau RS485, un bus USS RS485 si terminale de comanda digitale sau analogice. Rutina de configurare a placii initializeaza placile optionale de comunicare, senzori si SIMOLINK suportate pentru varianta de convertizor instalata.
Key Functions
Prelucrarea Controlului de Miscare
Placa CUMC ofera arhitectura de control pentru generatia originala MASTERDRIVES MC compact si chassis.
Interfete de Control Integrate
Standard connections include RS232 or RS485 service communication, an RS485 USS bus, and digital or analog control terminals.
Configurable Expansion
The board configuration routine initializes supported communication, sensor, and SIMOLINK option boards for the installed drive.
Official Specifications
| Control Unit Designation | CUMC — Control Unit Motion Control |
|---|---|
| Board Identification Code | 93 |
| Drive Unit Format | SIMOVERT MASTERDRIVES MC compact and chassis units |
| Main Processor Generation | C167 at 20 MHz |
| Resolutio Ingressus Analogici | 9 bit plus sign |
| Service Interface X300 | 9-pole SUB-D for RS232 or RS485 communication with a PC or OP1S |
| USS Interface SCom1 | RS485 on X103 terminals 27 and 28 |
| USS Interface SCom2 | RS485 on X103 terminals 25 and 26 |
| Positive Potentiometer Supply | +10 V ±1.3%; maximum 5 mA |
| Negative Potentiometer Supply | -10 V ±1,3 %; maximum 5 mA |
| X300 Auxiliary Output | +5 V; maximum 200 mA |
| Software Update Signal | Boot input on X300; low-active digital signal |
| Terminatio Bus | Switchable termination for SCom1 and SCom2 |
| Control Terminal Conductor Size | 0,14 to 1,5 mm²; AWG 16 maximum |
| Option-Board Configuration | Board configuration initializes supported CBx communication boards and the SLB SIMOLINK interface |
Quaestiones Frequenter Rogatae
Which drive family accepts 6SE7090-0XX84-0AD1?
It belongs to compatible SIMOVERT MASTERDRIVES MC compact and chassis units built around the CUMC control generation.
What should be backed up before replacing 6SE7090-0XX84-0AD1?
Save the complete parameter set, board configuration, motor data, encoder settings and communication addresses.
How can a PC or OP1S connect to 6SE7090-0XX84-0AD1?
Use the X300 nine-pole service socket with the required RS232 or RS485 wiring and bus termination.
Which USS connections are available on 6SE7090-0XX84-0AD1?
Two RS485 channels are provided as SCom1 and SCom2 on the X103 control terminal strip.
What must be checked when option boards are fitted to 6SE7090-0XX84-0AD1?
Confirmare omne typum tabulae installatae, fissuram, adressem et parametrum configurationis tabulae antequam incipias motorem.
Potestne 6SE7090-0XX84-0AD1 directe commutari cum tabula CUPM?
Generationes differunt in processore, memoria et quibusdam comportamentis signali; ideo migratio planificata et recensio parametrorum requiruntur.
Cur dispositio encoderis verificanda est post installationem 6SE7090-0XX84-0AD1?
Configuratio encoderis vel retroactionis incorrecta potest operationem clausam rectam impedire et commissionem axis tutam prohibere.
Compatibility & Ordering Notes
Index Compatibilitatis
- Confirmare convertorem esse unitatem SIMOVERT MASTERDRIVES MC compactam aut chassis, designatam ad generationem CUMC.
- Adaptare omnem tabulam optionalem communicationis, sensoris et SIMOLINK installatam ad configurationem tabularum servatam.
- Restituere et verificare parametros motoris, datos encoderis, attributiones I/O et adreses USS antequam axis activatur.