- Connecte supplitum electronicum ad pinum 5 et terram ad pinum 3.
- Utere dispositione cinguli rubricati MCP/MPP X30/X31.
- Adhibe anulum O et constringe nutum axis ad 3 Nm.
- Allinea indicem ad zero et constringe collare manubrii ad 2 Nm.
6FC5247-0AF12-1AA0 SINUMERIK Electronic Spindle Override Rotary Switch
The 16-position electronic override switch with Gray-code output, a 5 V supply and the spindle/rapid-traverse dial set.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6FC5247-0AF12-1AA0 |
| Typus Producti | Electronic rotary operator control |
| Functio principalis | Selecting spindle and rapid-traverse override |
| Applicatio | Compatible SINUMERIK MCP/MPP operator panels |
Sixteen settings
The 1x16G electronic version is assigned to spindle and rapid-traverse override.
Ribbon-cable connection
Electronic supply is on pin 5, with ground on pin 3.
Mechanical replacement
Central attachment, an O-ring and separate shaft/knob torques form the mounting arrangement.
Product Overview
6FC5247-0AF12-1AA0 provides electronic rotary selection for spindle and rapid-traverse override on compatible SINUMERIK operator panels. The 1x16G version uses Gray-code coding and includes the turquoise pointer and the assigned spindle and rapid-traverse dials.
The switch connects by ribbon cable and plug connector to the MCP/MPP X30/X31 arrangement. Its electronic supply-pin assignment differs from the mechanical rotary-switch variant, so both the wiring and mechanical replacement procedure matter during service.
Key Functions
Select the override setting
The electronic 1x16G rotary switch provides sixteen positions for spindle and rapid-traverse selection.
Transmit a coded position
Gray-code outputs pass the switch position through the ribbon-cable connector.
Fit the operator-panel cutout
Central attachment and an O-ring secure and seal the switch in the operator panel.
Official Specifications
| Switch settings | 16 positions; electronic 1x16G |
|---|---|
| Output coding | Gray Code |
| Supple voltage | 4.75–5.5 V DC with ±100 mV tolerance |
| Consumptio currentis | 25 mA typical; 75 mA maximum with all outputs loaded |
| Protectio contra polaritatem inversam | Up to 12 V |
| Tutela circuiti brevis | Limited protection, maximum 50 ms |
| Niveaum Tensionis Externi | Infimum: sub 0.6 V; supremum: super Vcc minus 1 V |
| Currentia maxima emissa | 10 mA |
| Allocatio connectoris | Pinus 3: terra; pinus 5: Vcc; pini 1, 2 et 4 non connecti |
| Pondera pinorum cum output codificato | Pini 6–10: 16, 8, 4, 2 et 1 |
| Torque activationis approximatum | 9 Ncm |
| Vis obstaculi | 2.5 Nm |
| Vita Servitii | 50,000 cycli |
| Ambiens Temperature | Operatio: −25 ad +85 °C; conservatio: −40 ad +135 °C |
| Examen vibrationis | 1 g; 2–200 Hz; 1 octava/min pro 133 min |
| Examen Impactus | 10 g, 11 ms |
Quaestiones Frequenter Rogatae
Can I wire 6FC5247-0AF12-1AA0 using the supply pin of the mechanical override switch?
The electronic variant takes Vcc on pin 5, whereas the mechanical variant uses pin 4.
Which panel connections accept 6FC5247-0AF12-1AA0?
The switch connects to an MCP or MPP through X30/X31.
What tightening torque should I use for the shaft fastening nut of 6FC5247-0AF12-1AA0?
Tighten the shaft fastening nut to 3 Nm using the specified 14 mm wrench.
How should I align the pointer when installing the knob on 6FC5247-0AF12-1AA0?
Align the arrow point with position zero on the scale before tightening the knob.
Quod momentum torque collet rotundum in 6FC5247-0AF12-1AA0 firmat?
Constringe nutem collet cum torque spanner ad 2 Nm.
Num possum 24 V supplitum tabulare directe ad 6FC5247-0AF12-1AA0 applicare?
Interruptor electronicus requirit specificatum supplitum 4.75–5.5 V DC.
Quae signatio ante ponendum 6FC5247-0AF12-1AA0 in foramine tabulae aptanda est?
Adaptato O-ring ad novam axem interruptoris et pressionem super eum retinete dum interruptor inseritur.