Conspectus
- Spatium pro exitu cavi ad angulum 35 graduum et pro ductu PG relinquere oportet.
- Diametrum cavi destinatum et magnitudinem conductoris terminalis obliquae uti oportet.
- Permitte terminatio solummodo ad extremitates segmenti.
- Mantene apparecchium extremum coniunctum in statu activo dum eius terminatio necessaria est.
6ES7972-0BB41-0XA0 SIMATIC PROFIBUS 35° Screw Bus Connector with PG Socket
A 35-degree PROFIBUS screw-terminal connector with a PG socket and switchable termination with an outgoing-bus disconnect function.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7972-0BB41-0XA0 |
| Typus Producti | RS 485 bus connector |
| Functio principalis | Bus connection and programming access |
| Applicatio | PROFIBUS device interfaces |
Programming access retained
The added PG socket provides access for a programming device at the installed bus connector.
Inclined cable routing
A 35-degree outlet routes the bus cable away from the device interface.
Selectable bus end
Switching on termination also disconnects the outgoing bus cable.
Product Overview
6ES7972-0BB41-0XA0 provides screw-terminal PROFIBUS wiring together with a local programming-device socket.
The inclined cable outlet and integrated termination suit an installed RS 485 node where commissioning access must remain available without removing the field-bus cable from its connector.
Key Functions
Connect a PG beside the permanent bus wiring
The programming socket carries the same pin assignment as the attached device through one-to-one contact connections.
Terminate a screw-wired segment
The bus conductors land at four screw terminals and the slide switch selects the integrated resistor network.
Isolate the outgoing cable at a bus end
Activating the terminating resistor disconnects the outgoing cable, making the selected connector the end of that segment.
Official Specifications
| Maximum PROFIBUS Transmission Rate | 12 Mbit/s |
|---|---|
| Cable outlet angle | 35° |
| Device Interface | Nine-pin D-sub male connector |
| Bus-cable termination | Four screw terminals for conductors up to 1.5 mm² |
| Controllo del resistore di terminazione | Rete integrata attivata da interruttore a scorrimento |
| Comportamento di disconnessione del bus | Bus in uscita disconnesso quando la terminazione è attivata |
| Alimentazione dal dispositivo connesso | 4.75–5.25 V DC |
| Maxima Consumptio Electrica | 5 mA |
| Diametro del cavo collegabile | 8 ± 0,5 mm |
| Operans ambientium temperatus | 0 ad +60 °C |
| Temperatura servandi et transportandi | −25 a +80 °C |
| Maximum Relative Humidity | 75% a +25 °C |
| Aestimatio Protectionis | IP20 |
| Presa per dispositivo di programmazione | Aptatus |
Quaestiones Frequenter Rogatae
Can I attach a programming device at 6ES7972-0BB41-0XA0 without replacing the bus connector?
Yes, this version includes a PG socket for programming-device access.
What happens to the outgoing line when I switch termination on at 6ES7972-0BB41-0XA0?
The outgoing bus cable is disconnected when the integrated terminating resistor is activated.
Will the PG socket on 6ES7972-0BB41-0XA0 change the device pin assignment?
No, the programming socket contacts are connected one-to-one with the connector pins.
Can I unplug 6ES7972-0BB41-0XA0 from a terminating end node while the segment is operating?
No, removing a connector with active termination from a segment end disrupts the bus.
Which supply must the connected device provide for 6ES7972-0BB41-0XA0?
Apparatus coniunctus 4.75–5.25 V DC praebere debet, cum maxima corrente connectoris 5 mA.
Num 6ES7972-0BB41-0XA0 eundem spatium pro exitu cavi requirit atque connexio anguli recti?
Non; eius exitus cavi inclinatus est ad angulum 35 graduum et spatium pro hac directione necessarium est.
Num 6ES7972-0BB41-0XA0 in nodo interiori ordinario cum terminatione activata installare possum?
Non; si terminatio in nodo interiori activatur, catena egrediens interrumpitur et nodi subsequentes inaccessibiles fiunt.