  • Conspectus
  • Hot Selling Models
  • Producta commendata
Conspectus
SIMATIC M7-300/400

6ES7961-1AA00-0AC0 SIMATIC M7 IF 961-DIO Digital I/O Submodule

A compact digital interface with eight inputs, eight outputs, edge-triggered interrupts, and a front sub-D connection.

Ad Primum Aspectum

Nota Siemens
Modellum 6ES7961-1AA00-0AC0
Typus Producti Digital I/O interface submodule
Functio principalis Discrete signal acquisition and switching
Applicatio Compatible M7 programmable and expansion modules

Filtratio input selectabilis

The input-delay setting applies a common delay of approximately 750 µs or 3 ms to the input channels.

Edge-triggered events

Rising and falling input edges can generate interrupts through configurable registers.

Protected DC switching

The digital outputs have electronic short-circuit protection and grouped electrical isolation.

Product Overview

6ES7961-1AA00-0AC0 adds discrete field-signal connections to a compatible M7 carrier module.

Selectable input filtering and edge interrupts support event-driven signal handling, while electronically protected outputs switch small DC loads.

Focus ordinandi: Match the M7 carrier, front-connector wiring, load supply, input filtering and output load.
Key Functions

Filtratio input selectabilis

The input-delay setting applies a common delay of approximately 750 µs or 3 ms to the input channels.

Edge-triggered events

Rising and falling input edges can generate interrupts through configurable registers.

Protected DC switching

The digital outputs have electronic short-circuit protection and grouped electrical isolation.

Official Specifications
Onboard channels 8 digital inputs and 8 digital outputs
Nominal field supply 24 V DC; permissible load-supply range 20.4–28.8 V
Input Signal Levels Altus: 13–30 V DC; bassus: −30 ad +5 V DC
Currentia intrantis signi unius 4–8.5 mA
Selectio communis retardationis intrantis Circa 750 µs aut 3 ms
Gruppatio isolationis intrantis 2 intrantes per gruppus isolatus
Gruppatio isolationis extrantis 4 extrantes per gruppus isolatus
Output Current 0.1 A nominalis; ambitus permittendus status activi 5–100 mA
ON-State Output Voltage L+ minus 1.5 V
Maxima onus lampadis 2,4 W
Frequentia Maxima Commutandi 500 Hz pro oneribus resistivis aut lamparum; 2 Hz pro oneribus inductivis 0.1 A
Organizatio interruptus intrantis 1 interruptus combinatus ex usque ad 8 fontibus
Coniunctio anterior conector sub-D 25-pin
Maxima cāpācitās cāblī signālis 1 000 m cum scuto; sine scuto 200 m ad retardationem intrantis 750 µs aut 600 m ad retardationem intrantis 3 ms
Onus suppeditationis portantis 30 mA referens ad 24 V in M7-300; 85 mA referens ad 5 V in M7-400
Ammissio Potentiae 2,4 W
Examen Isolationis 500 V DC
Dimensiones et Pondera 18.2 × 67 × 97 mm (l × a × p); 0.065 kg
Quaestiones Frequenter Rogatae

Can 6ES7961-1AA00-0AC0 generate an event when an input changes state?

Input interrupts can be configured for rising edges, falling edges, or both.

Can I set a different input filter on every channel of 6ES7961-1AA00-0AC0?

The selected delay of approximately 750 µs or 3 ms applies in common to all input channels.

How are the field inputs on 6ES7961-1AA00-0AC0 electrically grouped?

The eight inputs are isolated in groups of two.

Can I parallel the outputs of 6ES7961-1AA00-0AC0 for a larger load?

Parallel wiring of two outputs is not permitted.

Which connector carries the field signals on 6ES7961-1AA00-0AC0?

The front connection is a 25-pin sub-D socket.

Does 6ES7961-1AA00-0AC0 provide a separate diagnostic function?

The submodule has no diagnostic function.

Can 6ES7961-1AA00-0AC0 use a 500 m unshielded input cable?

The unshielded-cable limit is 600 m with the 3 ms input delay and 200 m with the 750 µs delay.

Compatibility & Ordering Notes
Before ordering 6ES7961-1AA00-0AC0: Match the M7 carrier, front-connector wiring, load supply, input filtering and output load.

Antequam Installatio

  • Install the submodule in a supported M7 programmable or expansion-module position.
  • Use the slot-dependent base address and the correct input, output and interrupt-register offsets.
  • Match signal-cable length to shielding and the selected common input delay.
  • Provide the required field supply, maintain the specified isolation groups and keep each output within its load rating.
Hot Selling Models
VIGE-03-FB-8-5POL-S
SIEN-4B-PS-KL
UC66PA3 BEF-Set-11
S2013FIB/HS/3SD
QFA65.1
OP-87900
BN60-rz
BN60-01z
Z1UZ 1U 68VDC 677610
571298.9001.01
R044229400