Conspectus
Siemens • SIMATIC PCS 7 / ET 200M
6ES7650-1AM31-6XX0 SIMATIC PCS 7 Redundant F-DO10 Relay MTA
The redundant F-DO10 relay MTA connects an ET 200M fail-safe ten-channel output module to relay field circuits with redundant fused supply inputs and LED indication.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7650-1AM31-6XX0 |
| Typus Producti | Terminatio collectiva decem-canalis de output relais fail-safe |
| Functio principalis | Terminates redundant fail-safe relay outputs from an ET 200M F-DO10 module |
| Applicatio vel series compatibiles | SIMATIC PCS 7 ET 200M safety stations using 6ES7326-2BF10-0AB0 |
Identificatio exacta.
Match 6ES7650-1AM31-6XX0 character by character and confirm the complete SIMATIC PCS 7 Redundant F-DO10 Relay MTA designation.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
The redundant F-DO10 relay MTA connects an ET 200M fail-safe ten-channel output module to relay field circuits with redundant fused supply inputs and LED indication.
Ten relay channels interface the approved ET 200M F-DO10 safety module to field circuits. The MTA supports the documented redundant I/O arrangement for PCS 7 safety applications. Fused redundant supplies and LED indications support channel and power troubleshooting.
Key Functions
Fail-Safe Output Termination
Ten relay channels interface the approved ET 200M F-DO10 safety module to field circuits.
Redundant Module Connection
The MTA supports the documented redundant I/O arrangement for PCS 7 safety applications.
Serviceable Power Distribution
Fused redundant supplies and LED indications support channel and power troubleshooting.
Official Specifications
| Compatible ET 200M Module | 6ES7326-2BF10-0AB0 |
|---|---|
| DC Output Range | 24 ad 150 V CC |
| AC Output Range | 120 to 220 V AC |
| Supple voltage | 24 V DC |
| Currens Alimentaria | 0.56 A |
| Rating Contactuum Relais | 5 A ad 230 V AC aut 24 V DC |
| Ambiens Temperature | -25 ad +70 °C |
| Codex Temperaturae | T4 |
| Potentia-Monitor Optio Nota | 24 V DC, 0.5 A |
| Ingressus Potentiae | Redundans et fusibilis |
| Indicatio status | Afișaje LED |
| Ponderis netum | 0.955 kg |
| Dimensiones Confectionis | 26 x 20.3 x 15 cm |
Quaestiones Frequenter Rogatae
Quod modulem output fail-safe coniungitur cum 6ES7650-1AM31-6XX0?
Utere specificatum ET 200M decem-channelum modulem output fail-safe.
Quot circuitus relay potes terminare in 6ES7650-1AM31-6XX0?
The assembly provides ten relay-output channels.
Which field-voltage ranges are supported by 6ES7650-1AM31-6XX0?
The relay outputs cover 24 to 150 V DC and 120 to 220 V AC within all contact ratings.
What current limit applies to the relay contacts of 6ES7650-1AM31-6XX0?
Keep each relay circuit within the documented 5 A contact rating and the connected load category.
How should redundant power be connected to 6ES7650-1AM31-6XX0?
Wire both approved 24 V DC feeds through the documented fused inputs and verify the LED indications.
What safety data should be preserved before replacing 6ES7650-1AM31-6XX0?
Retain the F-system project, safety signature, proof-test record, channel assignment and relay-load documentation.
What validation is required after installing 6ES7650-1AM31-6XX0?
Perform the authorized safety-function test, including both module paths, every relay channel, diagnostics and de-energized behavior.
Compatibility & Ordering Notes
Index Compatibilitatis
- Use only with the documented ET 200M fail-safe output module and approved PCS 7 safety architecture.
- Keep every AC and DC load within the relay ratings and preserve isolation requirements.
- Complete the site safety validation before returning the protected process to service.