Obtain a Free Quote

Our representative will contact you shortly.
Email
Nomen
Nomen societatis
Notula
0/1000

Siemens SIMATIC C7 6ES7626-2DG04-0AE3 C7-626 P/DP Unitas completa

Fabricator: Siemens
Status: Novissimum
Tempus Expectatus: In Stoc
Origo: Germania
Praestatio: 12 menses

  • Praevisio
  • Productum Overview
  • Functiones Principales
  • Official Specifications
  • FREQUENTLY ASKED QUESTIONS
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Pròdòt ràccumandà
Praevisio
SIMATIC C7 • C7-626/P DP

6ES7626-2DG04-0AE3 C7-626/P DP unitas completa

Unitas SIMATIC C7 adfixa in tabula, quae functiones controlleris, operatoris et distributae I/O combinat.

At a Glance

Fabricator Siemens
Numerus Articuli 6ES7626-2DG04-0AE3
Product Type C7-626/P DP unitas completa
Functio principalis Controllo integratum, operatio localis et communicatio PROFIBUS DP
Application / Compatible Series Systemata compacta SIMATIC C7 ad controllo machinarum

Identificatio exacta.

Match the complete article number and installed hardware revision.

System fit

Confirmare platformam, interfacies et ambientes ingeniorum.

Configuration Check

Insicere connectores, fixationem et accessoria requirita.

Productum Overview

6ES7626-2DG04-0AE3 pertinet ad familiam Siemens C7-626/P DP unitatum compactarum completarum. Unitatem controlleris et functionum operatoris cum ingressibus/egressibus digitalibus integratis pro automatione machinarum in tabulis combinat.

Hardware C7-626/P DP praebet 16 ingressus digitales et 16 egressus digitales. Signa campi 24 V DC, facultas PROFIBUS DP et subsidium S7 routing permittunt huic dispositivo ut operationem localem cum componentibus automationis distributis coordinet.

Focus ordinandi: congruunt cum numero articuli completo C7-626/P DP, apertura tabulae installata, connexione I/O et configuratione PROFIBUS.
Functiones Principales

Designatio Controlleris

6ES7626-2DG04-0AE3: C7-626 P/DP.

Familia Systematis

6ES7626-2DG04-0AE3: SIMATIC C7.

Architectura Dispositivi

6ES7626-2DG04-0AE3: PLC et unitas operatoris in eodem carcere.

Official Specifications
Ingressus Digitales 16
Tensio Nominalis Ingressus 24 V DC
Intervalum Insignis 1 Intrantis 11 ad 30 V
Intervalum intrantis signi 0 -3 usque ad 5 V
Currens Ingressus Signum 1 6 ad 11,5 mA
Morae Ingressus 1,2 ad 4,8 ms
Isolatio Intrantis Optocoupler, grupus 16
Ingressus Normalis EN 61131-2, Tipo 2
Emissiones Digitales 16
Tensio de oneratio de outputo 24 V DC
Currens exsitus per canallem 0,5 A
Onus Lampae maxime 5 W
Isolatio Externi Optocoupler, grupus 8
Currente de grupus de outputo 4 A ad 20 °C; 2 A ad 45 °C
Protectio contra curtum circuitum in effluenti Tempore electronicamente regulabile
Longitudo cavi non scutati 600 m maxime
Longitudo Cavi Scutati 1 000 m maxime
S7 Routing Supportata
Memoria Onus Integrated
Supporto non-retinentis No
FREQUENTLY ASKED QUESTIONS

Quae integrata I/O sunt disponibilia in 6ES7626-2DG04-0AE3?

Totum unitas praebet 16 digitalia intrada et 16 digitalia extrada.

Quae intervallo tensionis intradae logicam 1 repraesentat in 6ES7626-2DG04-0AE3?

Digitalia intrada accipiunt 11 ad 30 V pro logica 1 cum nominali 24 V DC alimentatione.

Quantum currentis singulae extradae 6ES7626-2DG04-0AE3 commutare possunt?

Singula digitalia extrada valentur ad 0.5 A sub documentatis condicionibus oneris.

Quae functio PROFIBUS inspicienda est dum 6ES7626-2DG04-0AE3 in servitium ducitur?

Verifica DP adressem, parametra bus, terminacionem et configuratas stationes distributae-I/O antequam incipias.

Potestne 6ES7626-2DG04-0AE3 S7 communicationem dirigere?

Yes. The exact C7 order-number family is listed as supporting S7 routing.

What panel work is required before replacing 6ES7626-2DG04-0AE3?

Compare the installed cutout, connector positions and wiring assignments before removing the existing unit.

Which output protection detail matters when wiring 6ES7626-2DG04-0AE3?

The digital outputs use electronically timed short-circuit protection and are galvanically isolated in groups of eight.

Compatibility & Ordering Notes
Verificatio Conpatibilitatis: Confirm that the existing device is the C7-626/P DP variant rather than another C7-626 version.
  • Record the PROFIBUS address and project configuration before replacement.
  • Check the 24 V DC field supply, connector pinout and digital-I/O group loading.
  • Compare the panel cutout and mounting hardware before installation.
Hot Selling Models
METSECT5DA060
VM3A1101
BD-B022
EPX420D
TC810R1024
G9SB-301-B
STEP-PS/1AC/24DC/2.5
EXB-REL8
RWX62.7034
AL-6MR-A
RL28-8-H-2000-IR/47/105
6ED1058-0BA08-0YA1
CP-BATT-7925G-STD
1762-OW16
6ES7972-0BB12-0XA0

Obtain a Free Quote

Our representative will contact you shortly.
Email
Nomen
Nomen societatis
Notula
0/1000
email ireAdSummum

Evolo Automation non est distributor autorizatus, nisi aliter specificatum, representativus vel affinis fabricantis huius producti. Omnia nomina commercialia et documenta proprietatis sunt suorum dominorum respective et praebentur ad identificationem et informationem.