Siemens SIMATIC S7-300 FM 355 C Modulus Controlus Continui 6ES7355-0VH10-0AE0
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Product Overview
- Key Functions
- Official Specifications
- Quaestiones Frequenter Rogatae
- Compatibility & Ordering Notes
- Hot Selling Models
- Producta commendata
Conspectus
Siemens · SIMATIC S7-300 FM 355
6ES7355-0VH10-0AE0 SIMATIC S7-300 FM 355 C Continuous Control Module
FM 355 C est modulus controlis continuus quattuor canalium pro systematibus S7-300, qui admittit signa ingressus tensionis, currentis, thermocuplae et Pt100, cum quattuor analogis egreditur continuus.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7355-0VH10-0AE0 |
| Typus Producti | Modulus functionis controlis continuus quattuor canalium |
| Functio principalis | Exequitur quattuor canales controlis clausi independens cum analogis signis processus I/O |
| Applicatio vel series compatibiles | Applicationes S7-300 ad controlandum processus, quae requirunt controllem PID continuum et signa analogica configurabilia |
Identificatio exacta.
Confer characterem ad characterem 6ES7355-0VH10-0AE0 et confirma designationem integram SIMATIC S7-300 FM 355 C Continuous Control Module.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
FM 355 C est modulus controlis continuus quattuor canalium pro systematibus S7-300, qui admittit signa ingressus tensionis, currentis, thermocuplae et Pt100, cum quattuor analogis egreditur continuus.
Hoc modulum quattuor independentes clausas regulandas functiones exequitur.
Key Functions
Quattuor Canales Regulandi
Hoc modulum quattuor independentes clausas regulandas functiones exequitur.
Ingressus Sensorum Flexibiles
Ingressus analogici configurabiles signa standardia tensionis, currentis, thermopilae et Pt100 accipiunt.
Output Analogici Continui
Quattuor canales output signa imperativa tensionis aut currentis ad ultimos elementos regulandi praebent.
Official Specifications
| Canales Controlis | 4 |
|---|---|
| Egressus Analogici | 4 |
| Intervalla Tensionis Exirendi | 0 ad 10 V et -10 ad +10 V |
| Intervalla pro Egressu Currentis | 0 ad 20 mA et 4 ad 20 mA |
| Typus sensorum input | Tensio, currus, thermocoppula et Pt100 |
| Thermocuplae Admissae | B, J, K, R et S |
| Maxima resolutio input | 14 bit |
| Longitudo maxima vitarum signali | 200 m |
| Longitudo maxima cavi pro 80 mV / thermocoppula | 50 m |
| Minima onus pro output tensio | 1 KΩ |
| Maxima onus pro output currus | 500 Ω |
| Stabilizatio output analogi, onus resistivum | 0,1 ms |
| Stabilizatio output analogi, onus capacitivum | 3.3 ms |
| Stabilizatio output analogi, onus inductivum | 0,5 ms |
| Host system | SIMATIC S7-300 |
Quaestiones Frequenter Rogatae
How many control loops can 6ES7355-0VH10-0AE0 execute?
Four independent continuous-control channels are available.
Which temperature sensors can connect to 6ES7355-0VH10-0AE0?
The approved input configurations include Pt100 and the listed thermocouple types.
How many continuous outputs are provided by 6ES7355-0VH10-0AE0?
Four analog output channels are available.
Can 6ES7355-0VH10-0AE0 drive both voltage and current actuators?
Yes; configure the supported 0–10 V, ±10 V, 0–20 mA or 4–20 mA range.
What must be saved before replacing 6ES7355-0VH10-0AE0?
Preserve the STEP 7 configuration, controller parameters, ranges, scaling and commissioning values.
What cable practice applies to 6ES7355-0VH10-0AE0?
Use shielded analog wiring, observe the specified length limits and separate it from power cables.
What should be tested after installing 6ES7355-0VH10-0AE0?
Validate every input, output range, loop direction, tuning value, limit and fallback response.
Compatibility & Ordering Notes
Index Compatibilitatis
- Use the correct FM 355 C hardware entry and parameterization software.
- Match every sensor type, measuring range and analog-output load.
- Restore and validate all controller tuning and fallback parameters.