Siemens SIMATIC S7-300F CPU 319F-3 PN/DP 6ES7318-3FL00-0AB0
Fabricator: Siemens
Status: Novissimum
Tempus Expectatus: In Stoc
Origo: Germania
Praestatio: 12 menses
Email: [email protected]
whatsapp: +86-18150117685
- Praevisio
- Productum Overview
- Functiones Principales
- Official Specifications
- FREQUENTLY ASKED QUESTIONS
- Compatibility & Ordering Notes
- Hot Selling Models
- Pròdòt ràccumandà
Praevisio
SIEMENS • SIMATIC S7-300F
6ES7318-3FL00-0AB0 SIMATIC S7-300F CPU 319F-3 PN/DP
The CPU 319F-3 PN/DP is a fail-safe S7-300 controller for personnel safety, machine safety, and burner control, while also supporting a standard automation program.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7318-3FL00-0AB0 |
| Product Type | Fail-safe programmable controller CPU |
| Functio principalis | Runs safety-related and standard automation programs over PROFIBUS and PROFINET |
| Applicatio vel series compatibiles | SIMATIC S7-300F controller systems |
Identificatio exacta.
Match 6ES7318-3FL00-0AB0 character by character and confirm the complete SIMATIC S7-300F CPU 319F-3 PN/DP designation.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Productum Overview
The CPU 319F-3 PN/DP is a fail-safe S7-300 controller for personnel safety, machine safety, and burner control, while also supporting a standard automation program.
The F-CPU executes a safety program and can also run the standard automation application. The controller detects an inconsistent safety program during startup and enters STOP with a diagnostic event. The fail-safe default process image is 1,024 bytes for inputs and 1,024 bytes for outputs.
Functiones Principales
Combined Safety and Standard Control
The F-CPU executes a safety program and can also run the standard automation application.
Safety Startup Consistency Check
The controller detects an inconsistent safety program during startup and enters STOP with a diagnostic event.
Expanded Safety Process Image
The fail-safe default process image is 1,024 bytes for inputs and 1,024 bytes for outputs.
Official Specifications
| Hardware Release | 01 |
|---|---|
| Firmware Baseline | V2.5.2 |
| Default Process Image | 1.024 bytes input et 1.024 bytes output |
| Programmata Securitatis et Normarum | Utrumque suportatur |
| Initiale STEP 7 Baseline | V5.4 SP1 cum HSP 121 |
| Firmware V2.6 Engineering Baseline | STEP 7 V5.4 SP2 cum HSP 143 |
| Firmware V2.7 Engineering Baseline | STEP 7 V5.4 SP4 |
| Pacum Optionis Securitatis | S7 Distributed Safety V5.4 SP1 aut ultra |
| Detectio Consistentiae Initii Securitatis | Supportata |
| Responsio Programmatum Securitatis Inconsistens | CPU mutat in STATUM STOP |
| Eventus Tamponis Diagnosticorum | Programma Securitatis Inconsistens |
| Tractatio RAM ad ROM | Bloci Datarum Programmatum Securitatis non copiantur e memoria operativa ad memoriam onerandi |
| Operationes Blocorum Datarum F | Creatio et deletio per SFC 22, SFC 23 et SFC 82 non suportantur |
FREQUENTLY ASKED QUESTIONS
Pot 6ES7318-3FL00-0AB0 exequere programma normale simul cum programma securitatis?
F-CPU sustinet applicationes automationis securitatis et normales.
Quod pachetum STEP 7 requiritur pro basi V2.5.2 6ES7318-3FL00-0AB0?
Utere STEP 7 V5.4 SP1 cum HSP 121 et optione S7 Distributed Safety requisita pro applicationibus securitatis.
Quae magnitudo imaginis processus est praedefinita pro securitate pro 6ES7318-3FL00-0AB0?
Praedefinitum est 1 024 octeta pro intratis et 1 024 octeta pro extratis.
Quomodo 6ES7318-3FL00-0AB0 reagit ad programmatum securitatis incoerens ad initium?
CPU detegit incoerentiam, ingreditur STATUM STOP et notat eventum diagnosticum.
Possuntne F-blocos dati creari vel deleri dynamice in 6ES7318-3FL00-0AB0?
The specified create and delete system functions do not support F-data blocks.
What happens to safety data blocks during RAM-to-ROM on 6ES7318-3FL00-0AB0?
Safety-program data blocks are not copied from work memory into load memory.
Which applications are appropriate for 6ES7318-3FL00-0AB0?
The controller is intended for personnel safety, machine safety and burner-control tasks together with standard automation.
Compatibility & Ordering Notes
Index Compatibilitatis
- Retain the validated STEP 7 and S7 Distributed Safety engineering environment for the installed firmware.
- Back up the standard and safety programs and record the accepted safety signature before replacement.
- Confirm the complete PROFIBUS, PROFINET and fail-safe I/O configuration before commissioning.