Siemens SIMATIC S7-300 CPU 317-2 DP 6ES7317-2AJ10-0AB0
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Product Overview
- Key Functions
- Official Specifications
- Quaestiones Frequenter Rogatae
- Compatibility & Ordering Notes
- Hot Selling Models
- Producta commendata
Conspectus
SIEMENS · SIMATIC S7-300
6ES7317-2AJ10-0AB0 SIMATIC S7-300 CPU 317-2 DP
CPU 317-2 DP praebet 512 KB memoriae operativae, interfaciem MPI/DP et secundam interfaciem PROFIBUS DP pro machinis automationis distributis S7-300.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7317-2AJ10-0AB0 |
| Typus Producti | Programmabilis logicus controller CPU cum duplicibus interfaciis aptis ad PROFIBUS |
| Functio principalis | Exequitur programmatum controlis S7-300 et administrat dispositiva PROFIBUS DP distributa |
| Applicatio vel series compatibiles | Statio SIMATIC S7-300 quae requirit 512 KB memoriae operativae et duas interfacies aptas ad DP |
Identificatio exacta.
Confer 6ES7317-2AJ10-0AB0 charactere per characterem et confirma integram designationem SIMATIC S7-300 CPU 317-2 DP.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
CPU 317-2 DP praebet 512 KB memoriae operativae, interfaciem MPI/DP et secundam interfaciem PROFIBUS DP pro machinis automationis distributis S7-300.
Portus MPI/DP integratus et portus secundus DP suffragantur programmationem, communicationem controlleris et I/O distributum. Processus praebet 512 KB memoriae operativae pro applicatione S7-300 configurata. Carta SIMATIC Micro Memory portat memoriam oneris et data projecti.
Key Functions
Dual Fieldbus Integration
The integrated MPI/DP port and second DP port support programming, controller communication and distributed I/O.
Controller Memory
The processor provides 512 KB of work memory for the configured S7-300 application.
Memoria oneris removibilis
A SIMATIC Micro Memory Card carries the load memory and project data.
Official Specifications
| Memoria operativa | 512 KB |
|---|---|
| Interfaccia di comunicazione primaria | MPI/PROFIBUS DP |
| Velocitas interfaciei principalis | Usque ad 12 Mbit/s |
| Interfacs communicatiōnis secundārius | Master/slave PROFIBUS DP |
| Memoria oneris removibilis | Cardina Micro Memoriae SIMATIC requiritur |
| Tensio nominalis supplicii | 24 V DC |
| Communicatio S7 | Supportata |
| PROFIBUS DP Master Function | Supportata |
| PROFIBUS DP Slave Function | Supportata |
| Ponderis netum | 0.517 kg |
| Dimensiones Confectionis | 13.2 x 15.0 x 9.1 cm |
| Articulus successor | 6ES7317-2AK14-0AB0 |
Quaestiones Frequenter Rogatae
Ad quas retes coniungere possum 6ES7317-2AJ10-0AB0?
Utere interfacie MPI/PROFIBUS DP integrata et altera interfacie PROFIBUS DP magistri/servi.
Quanta memoria operativa in 6ES7317-2AJ10-0AB0 disponibilis est?
CPU 512 KB memoriae operativae praebet.
Num 6ES7317-2AJ10-0AB0 cardinem memoriae requirit?
Ita; insere compatibilem SIMATIC Micro Memory Card, quam projectum probatum utitur.
Quid servare debes antequam 6ES7317-2AJ10-0AB0 substituis?
Serva projectum STEP 7, contenta cardinis memoriae, adressem MPI, adressem DP et configurationem communicationis.
Can 6ES7317-2AJ10-0AB0 operate as a DP slave?
Yes; the second interface supports the configured PROFIBUS DP slave role.
What must match when exchanging 6ES7317-2AJ10-0AB0?
Match the complete article number, hardware revision, firmware, memory card and network configuration.
What should be tested after installing 6ES7317-2AJ10-0AB0?
Verify CPU startup, both communication interfaces, distributed I/O, alarms and process operation.
Compatibility & Ordering Notes
Index Compatibilitatis
- Use the exact S7-300 hardware entry configured in STEP 7.
- Retain the verified memory card and project backup.
- Validate both integrated communication interfaces after replacement.