Siemens 6ES7241-1CH31-0XB0 SIMATIC S7-1200 CM 1241 RS422/485 Module
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Usa le schema de contactos del connectore D-sub femina de nove pinnas pro le modo electrico seligite.
- Provide le termination externe del linea.
- Adapta le velocitate de transmission, le paritate e le bits de stop al apparato partner.
- Includi 240 mA in le budget de potentia de 5 V del CPU.
- Selige le longitude del cable pro le velocitate de transmission operative.
6ES7241-1CH31-0XB0 SIMATIC S7-1200 CM 1241 RS422/485 Module
A CM 1241 module with an RS422/485 port, a female nine-pin D-sub connector and configurable serial parameters.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7241-1CH31-0XB0 |
| Typus Producti | Serial communication module |
| Functio principalis | Exchanging serial device data |
| Applicatio | Compatible S7-1200 CPU configurations |
Two electrical modes
The port operates as RS422 or RS485.
Flexible character format
Baud rate, parity and stop bits can be configured.
Isolated serial connection
Isolatio portus ad 500 V AC per unum minutum examinatur.
Product Overview
6ES7241-1CH31-0XB0 addit portum communicationis RS422/485 ad controllerem S7-1200 compatibilem. Interfacs D-sub femina novem-pinna supportat connexionem seriam et applicationem Freeport.
Modulus ab omnibus 5 V CPU suppeditatur. Optiones internae bias configurabiles non tollunt necessitatem terminationis lineae externae, et longitudo maxima cavi scutati pendet a velocitate baud.
Key Functions
Coniungite dispositivum seriale
Portus operationem electricam RS422 et RS485 per coniunctionem D-sub femina novem-pinna supportat.
Statue framen seriale
Velocitas, paritas et bitus stop configurabiles portum ad dispositivum socium adaptant.
Coordina transmissionem
RS422 supportat controllem fluxus XON/XOFF et output RTS indicat transmissionem activam.
Official Specifications
| Modi electrici portus | RS422 aut RS485 |
|---|---|
| Conector | connextio femina D-sub novem-pinna |
| Baudis Selectibilibus | 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 76800 aut 115200 bit/s; praedefinitus 9600 bit/s |
| Praecepta paritatis | Nulla, aequa, impar, signum aut spatium; praedefinita nulla |
| Bitus Stop | 1 aut 2; praedefinitus 1 |
| Tensio modi communis | −7 ad +12 V per 1 s; 3 V RMS continuo |
| Minima tensio transmittendi differentialis | 2 V ad onerem 100 Ω; 1.5 V ad onerem 54 Ω |
| Bias internus facultativus | 10 kΩ ad +5 V super B/pin 3 et 10 kΩ ad terram super A/pin 8 |
| Impedantia minima intrantis receptoris | 5.4 kΩ, includens terminationem |
| Limina et hysteresis receptoris | ±0.2 V limen minimum; 60 mV hysteresis typica |
| Examen Isolationis | 500 V AC per 1 minutum, signa serialia ad terram chassidis et ad communem logicam CPU |
| Maxima Longitudo Cavi Scutati | 1000 m, secundum baud ratem |
| Imperium Fluxus | XON/XOFF in modo RS422 |
| Intervalum temporis expectandi | 0–65535 ms |
| 5 V bus consumption | 240 mA |
| Dispergo Potentiam | 1,2 W |
| Dimensiones | 30 × 100 × 75 mm (W × H × D) |
| Pondus Approximatum | 155 g |
Quaestiones Frequenter Rogatae
Does the internal bias of 6ES7241-1CH31-0XB0 remove the need for line termination?
External termination is required even when an internal bias option is selected.
Which pins of 6ES7241-1CH31-0XB0 are used only for RS422 transmission?
Pins 2 and 9 carry the dedicated RS422 transmit signals and are not used for RS485.
What serial settings does 6ES7241-1CH31-0XB0 use by default?
The default settings are 9600 bit/s, no parity and one stop bit.
Can I use XON/XOFF flow control with 6ES7241-1CH31-0XB0?
XON/XOFF flow control is supported in RS422 mode.
Is the 1000 m cable limit of 6ES7241-1CH31-0XB0 valid at every baud rate?
The maximum shielded cable length is 1000 m and depends on the selected baud rate.
How is 6ES7241-1CH31-0XB0 powered by the controller?
The module draws 240 mA from the CPU 5 V DC bus.
What does the RTS output of 6ES7241-1CH31-0XB0 indicate?
The TTL-level RTS signal is active during transmission and inactive at other times.