Siemens 6ES7194-4AN00-0AA0 ET 200pro CM IM PN DP M12 7/8-Inch Connection Module
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Use b-coded M12 connectors for PROFIBUS DP and d-coded M12 connectors for PROFINET.
- Use five-wire 7/8-inch power cables for the separate 1L+ and 2L+ supply circuits.
- Limit incoming 1L+ and 2L+ current to 8 A each and retain the separate internal busbar limits.
- P1 R and P2 R support the CPU ring arrangement from firmware V3.2.
- Switch off both supply circuits before removing any 7/8-inch power connector.
- Terminate the PROFIBUS subnet at its ends with the appropriate external M12 terminating connector.
- Fit caps to every unused socket and keep the CPU RJ45 socket sealed when it is not used.
6ES7194-4AN00-0AA0 ET 200pro CM IM PN DP M12 7/8-Inch Connection Module
A CPU connection module with four M12 network connections and two 7/8-inch power connections for the ET 200pro IM 154-8 PN/DP CPU.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7194-4AN00-0AA0 |
| Typus Producti | CPU network and power connection module |
| Functio principalis | Routes field network and supply connections to the CPU |
| Applicatio | ET 200pro IM 154-8 PN/DP CPU assemblies |
Two field networks
The module provides the M12 connections for PROFINET and PROFIBUS DP.
Power in and through
Conectoribus quinque-pinnis 7/8-pollicibus suppellex et circuitus per electronicam et onera suppeditantur.
Coniunctio in campo tutata
Fossae inusitatae operculis congruentibus claudendae sunt, ut gradus protectionis compositi servetur.
Product Overview
6ES7194-4AN00-0AA0 coniunctiones in campo et ad supellectilem praebet coniunctio CPU ET 200pro IM 154-8 PN/DP.
Modulus CM IM PN DP M12, 7/8-pollicis portus PROFINET duos, coniunctiones PROFIBUS DP intrantes et egredientes, necnon coniunctiones supellectilis 24 V ad conectora in campo adducit; coniunctio programmatoria RJ45 separata in CPU manet.
Key Functions
Coniungere PROFINET et PROFIBUS DP
D-codificata conectora M12 pro PROFINET, b-codificata conectora M12 pro PROFIBUS DP intrante et egrediente utuntur.
Suppellex et circuitus 24 V per coniunctionem et per circuitum transire debent.
Conectora 7/8-pollicia coniunctiones intrantes et egredientes pro supellectile electronica/encoder 1L+ et pro supellectile oneris 2L+ praebent.
Mantere clausuram conexionis in campo
Conectora recte inserta et tecta idonea in foraminibus non usitatis protectionem aggregatam IP65, IP66 aut IP67 conservant.
Official Specifications
| Portus PROFINET in campo | Duo foramina M12 codice d: X02 P1 R et P2 R |
|---|---|
| Portus PROFIBUS DP in campo | Duae connexiones M12 codice b: X01 DP1 cum contactibus masculis et DP2 cum contactibus femininis |
| Dispositio conectoris potentiae | Duae connexiones quinque-pinnatae 7/8-pollices: X03 ad suppetias intrantes et X04 ad transductionem |
| Tensio circuitus suppetiarum | 24 V DC pro suppetiis electronici/encoderis 1L+ et suppetiis oneris 2L+ |
| Currente maxima de alimentatione ingressante | 8 A pro 1L+ et 8 A pro 2L+ |
| Limites interne de currente in barra omnibus | 5 A pro 1L+ et 10 A pro 2L+ |
| Assignation de pin del conector de potentia | 1: 2M; 2: 1M; 3: terra functionalis; 4: 1L+; 5: 2L+ |
| Pin de signal PROFIBUS DP | 2: data A; 4: data B; 5 et filet: terra functionalis |
| Medium del cable de rete de campo | PROFIBUS DP: cable bipolare con scudo; PROFINET: cable quadripolare con scudo |
| Connector tightening torque | 1.5 N·m for the connector knurled screws |
| Assembled ingress protection | IP65, IP66 or IP67 with correctly connected plugs and caps on all unused sockets |
| Dimensiones (L × H × D) | 90 × 130 × 51 mm |
| Approximate connection-module weight | 565 g |
Quaestiones Frequenter Rogatae
Which PROFINET ports on 6ES7194-4AN00-0AA0 are designated for a ring topology?
P1 R et P2 R sunt porturile inelare când se folosește un CPU IM 154-8 PN/DP cu versiunea de firmware 3.2 sau ulterioară.
Se poate folosi aceeași codificare a conectorului M12 pentru ambele rețele pe 6ES7194-4AN00-0AA0?
PROFIBUS DP folosește conectori M12 cu codificare b, în timp ce PROFINET folosește conectori M12 cu codificare d.
Se poate îndepărta conectorul de alimentare de 7/8 inch de pe 6ES7194-4AN00-0AA0 în timpul funcționării?
Înainte de a îndepărta un conector de 7/8 inch, opriți atât alimentarea electronică/encoder 1L+ cât și alimentarea de sarcină 2L+.
Dacă 8 A intră în alimentarea 1L+ a dispozitivului 6ES7194-4AN00-0AA0, pot trece toți cei 8 A prin bara de bus internă?
Bara de bus internă 1L+ este limitată la 5 A, rămânând 3 A pentru trecerea externă în exemplul cu intrarea de 8 A.
Cum sunt protejate soclurile neutilizate de pe 6ES7194-4AN00-0AA0?
Închideți fiecare soclu M12 și fiecare soclu de 7/8 inch neutilizat cu capacul corespunzător pentru a menține gradul de protecție la intrarea corpurilor străine.
Conține 6ES7194-4AN00-0AA0 soclul de programare RJ45 pentru CPU?
The RJ45 programming connection is on the IM 154-8 PN/DP CPU, not on this field connection module.
Can pin 1 of the PROFIBUS connector on 6ES7194-4AN00-0AA0 power another station?
The P5V2 voltage on pin 1 is only for the external terminating resistor and must not be looped through to the next connector.