Conspectus
Siemens · SIMATIC ET 200M
6ES7153-2BB00-0XB0 SIMATIC ET 200M IM 153-2 FO High Feature Interface Module
The IM 153-2 FO High Feature is the optical PROFIBUS DP interface for an ET 200M station, supporting up to eight S7-300 I/O modules, integrated fiber-optic connectivity and system, software or flying redundancy where configured.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7153-2BB00-0XB0 |
| Typus Producti | Fiber-optic PROFIBUS DP interface module |
| Functio principalis | Connects an ET 200M station to optical PROFIBUS DP with high-availability functions |
| Applicatio vel series compatibiles | ET 200M distributed I/O stations with up to eight S7-300 modules and approved redundancy configurations |
Identificatio exacta.
Match 6ES7153-2BB00-0XB0 character by character and confirm the complete SIMATIC ET 200M IM 153-2 FO High Feature Interface Module designation.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
The IM 153-2 FO High Feature is the optical PROFIBUS DP interface for an ET 200M station, supporting up to eight S7-300 I/O modules, integrated fiber-optic connectivity and system, software or flying redundancy where configured.
The integrated fiber-optic interface connects the ET 200M station to an optical PROFIBUS DP segment. The High Feature version supports system, software and flying redundancy under the documented conditions. Acts as the DP slave interface for up to eight supported S7-300 modules.
Key Functions
Coniunctio optical PROFIBUS
Interficies optica integrata connectit stationem ET 200M ad segmentum optical PROFIBUS DP.
Optiones high-availability
Versio High Feature suadet redundancy systematis, software et flying sub condicionibus documentatis.
Statio modularis capitis ET 200M
Agit ut interfacies DP slave pro usque ad octo modulos S7-300 supportatos.
Official Specifications
| Modulus Interfacis | IM 153-2 FO High Feature |
|---|---|
| Systema Distributum I/O | ET 200M |
| Rōlum Rētis | Servus PROFIBUS DP |
| Interfacing Physica | Optica integrata |
| Maxima celeritas transmissionis | 12 Mbit/s |
| Maximi moduli I/O | 8 moduli S7-300 |
| Supple voltage | 24 V DC |
| Redundantia Systematis | Supportata |
| Redundantia Software | Supportata |
| Redundantia Volans | Supportatus cum configuratione specificata |
| Mons Redundantis Paris | Modulus Bus Activus BM IM/IM |
| Requisitum GSD pro Redundantia Volante | IM 153-2 GSD revisio 5 |
| Operatio F-I/O | Supportatus cum modulis S7-300 fail-safe approbatis |
| Commutatio Modulorum | Substitue tantum cum modulus interface affectus est exenergizatus |
Quaestiones Frequenter Rogatae
What network medium is used by 6ES7153-2BB00-0XB0?
Use the approved optical PROFIBUS DP cable and connectors for the integrated fiber interface.
How many S7-300 modules can be installed behind 6ES7153-2BB00-0XB0?
The station can contain up to eight supported S7-300 I/O modules.
Can 6ES7153-2BB00-0XB0 be installed as a redundant interface pair?
Yes; use two interface modules on the specified active BM IM/IM bus module.
Which redundancy modes are available with 6ES7153-2BB00-0XB0?
System, software and flying redundancy are supported when all documented system conditions are met.
What address must be set on a replacement 6ES7153-2BB00-0XB0?
Set the same PROFIBUS DP address used by the removed interface module.
Can 6ES7153-2BB00-0XB0 operate with fail-safe S7-300 I/O?
Yes; use only the compatible F-I/O versions approved for this interface generation.
What should be checked after replacing 6ES7153-2BB00-0XB0?
Verify optical polarity, DP address, station configuration, active-interface status, diagnostics and every installed I/O module.
Compatibility & Ordering Notes
Index Compatibilitatis
- Use only the approved optical PROFIBUS components and observe transmitter-to-receiver polarity.
- For redundant installations, match the BM IM/IM bus module and configured redundancy type.
- Restore the original DP address and ET 200M hardware configuration before startup.