  • Conspectus
  • Hot Selling Models
  • Producta commendata
Conspectus
SIEMENS SIMATIC ET 200pro

6ES7143-4BF50-0AA0 SIMATIC ET 200pro 4DI/4DO Digital I/O Module

Four digital inputs and four 0.5 A outputs share a 24 V DC electronic module with short-circuit diagnostics.

Ad Primum Aspectum

Nota Siemens
Modellum 6ES7143-4BF50-0AA0
Typus Producti Mixed digital electronic module
Functio principalis Acquire sensors and switch field actuators
Applicatio ET 200pro distributed I/O stations

Mixed field signals

Four inputs and four outputs combine sensing and actuation.

Protected outputs

Electronic short-circuit protection is provided per output channel.

Separate connection face

Select the matching M12 connection module for the field cables.

Product Overview

6ES7143-4BF50-0AA0 combines four P-reading digital inputs with four current-sourcing 24 V DC outputs in the ET 200pro system.

The inputs and output loads are supplied from 2L+, and the output channels are rated at 0.5 A each. Short-circuit diagnostics and green channel status indicators support local fault checks.

Focus ordinandi: Match the 24 V DC load group, four mixed I/O socket assignments and the separately ordered connection module.
Key Functions

Read sensors at the machine

The four inputs use IEC 61131 Type 3 characteristics and accept two-wire sensors with a maximum 1.5 mA quiescent current.

Control DC actuators

The four outputs can operate solenoid valves, DC contactors and indicator lamps within the 0.5 A per-channel limit.

Locate output and supply faults

Informatio diagnosticas disponibilis est pro circuitus breves output et circuitus breves suppletionis encoder, simul cum indicatione status input et output viridis.

Official Specifications
Canalis Input Digitalis et Output 4 input et 4 output current-sourcing
Tensio Nominalis et Tensio Input 24 V DC
Limina Signali Inputii Signum 0: −3 ad +5 V; signum 1: +11 ad +30 V
Caracteristica input Lectura P; Typus IEC 61131-3
Typica introitus currentis signi-1 7 mA
Délai d’entrée maximal 3 ms pro utroque transitione
Maxima Cabello Campo Non Scutata 30 m pro input et output
Currentis Output Aestimatus 0,5 A per canalēm
Totus Currus Exitus 2 A per gruppus usque ad 55°C, omnes positiones montandi
Minimum voltatio output signi-1 2L+ − 0.8 V
Maximum OFF-State Residual Current 0,5 mA
Protectio contra curtum circuitum in effluenti Electronic per channel; typical threshold 0.7 A
Limitis Tensionis Inductivae ad Desactivationem Typically 2L+ − 47 V
Frequentia Maxima Commutandi Resistive: 100 Hz; inductive: 0.5 Hz; lamp: 1 Hz
Maxima onus lampadis 5 w
Currentis Alimentatio Encoderis 1 A maximum up to 55°C
Perditio potentiæ typica 2 W
Backplane Isolation Isolated from all other circuit components; 707 V DC type test
Indicatio status canalium Green LEDs for digital inputs and outputs
Dimensiones et Pondera 45 × 130 × 35 mm (W × H × D); approximately 140 g
Quaestiones Frequenter Rogatae

Does 6ES7143-4BF50-0AA0 come with the field connection module?

No, the bus module is included but the I/O connection module must be ordered separately.

Can I use 6ES7143-4BF50-0AA0 with the CM IO 4xM12 connection face?

Yes, CM IO 4xM12 and CM IO 4xM12P connection modules provide the listed four-socket field connection.

Which pins carry the input and output signals for 6ES7143-4BF50-0AA0?

On each of the four M12 sockets, pin 4 carries the digital input and pin 2 carries the corresponding digital output.

Can I parallel outputs on 6ES7143-4BF50-0AA0 to obtain more than 0.5 A?

No, parallel operation is allowed for redundant load control but not to increase output current.

Will 6ES7143-4BF50-0AA0 accept a two-wire sensor?

Yes, a two-wire sensor can be connected when its quiescent current does not exceed 1.5 mA.

What lamp load can one output of 6ES7143-4BF50-0AA0 switch?

The maximum lamp load is 5 W.

How quickly can 6ES7143-4BF50-0AA0 switch an inductive actuator?

Frequentia maxima commutandi pro onere inductivo est 0.5 Hz.

Compatibility & Ordering Notes
Before ordering 6ES7143-4BF50-0AA0: Select the 4DI/4DO 0.5 A electronic module and the corresponding field connection module for the installed ET 200pro station.

Compatibility Checklist for 6ES7143-4BF50-0AA0

  • Order the CM IO connection face separately and use the pin assignment for this mixed module.
  • Keep output loads within 0.5 A per channel and 2 A per group.
  • Limit unshielded input and output cables to 30 m.
  • Utere pino 1 pro suppetitione encoderis ab 2L+, pino 3 pro 2M, et pino 5 pro terra functionali in modulis connexionis M12 enumeratis.
Hot Selling Models
Allen-Bradley 140M-C2T-B10
6SE3290-0DA87-0FA1
NBB10-30GM50-E2-C3-V1
V52 ABA 2022AA2
ZK1090-3191-0030
ABB AL26-30-10
FAZ-C10/2 278756
ABB S282
7700-44511-S7V0050
3RS1800-2BW00
EDS-205
7000-08041-6300500
Allen-Bradley 800T-Q10W
6ES5725-0AK00
M32-XHI02 + DIL M32-XSPR 240

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.