Siemens 6ES7142-4BF00-0AA0 ET 200pro 8 DO 24 V DC 0.5 A Electronics Module
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Use a 24 V DC load supply and stay within 0.5 A per channel and 4 A per group up to 55 °C.
- Order the required I/O connection module separately from the included bus module.
- Do not parallel outputs for increased current; the supported parallel case is redundant control of a load.
- Observe the different switching-frequency limits for resistive, inductive, and lamp loads.
- Keep shielded or unshielded field cables within 30 m.
- When driving a digital input, jumpering 1M and 2M removes the separation between 1L+ and 2L+.
6ES7142-4BF00-0AA0 ET 200pro 8 DO 24 V DC 0.5 A Module electronicus
Modulus electronicus ET 200pro ad octo output, cum 0.5 A per canal, diagnosticum modularum, et modulo bus inclusum; modulus connexionis I/O separatim requiritur.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7142-4BF00-0AA0 |
| Typus Producti | Digital output electronics module |
| Functio principalis | Commutat actuatrices CC per output current-sourcing |
| Applicatio | SIMATIC ET 200pro distributed I/O stations |
Octo output sourcing
Unusquisque output commutat usque ad 0.5 A ex supply 24 V DC pro onere.
Diagnostics Moduli
Indicator SF ruber errores gruppi denotat; indicatio status output viridis est.
Connnector campi separatus
Modulus bus inclusus est; modulus connexionis I/O compatibilis separatim ordinatur.
Product Overview
6ES7142-4BF00-0AA0 commutat octo output digitalia current-sourcing in statione SIMATIC ET 200pro.
Electronica praebet protectionem electronicam contra curtum circuitum per channellum et diagnosticam defectuum in modulo, cum currente nominali 0.5 A per output et maxima currente gruppi 4 A usque ad 55 °C; modulus connexionis ad campum est componentum separatum.
Key Functions
Commutare onera DC per octo outputs.
Outputs current-sourcing suppeditant onera DC usque ad 0.5 A per channellum.
Limitare et referre defectus output.
Protectio electronica contra curtum circuitum operat per channellum, dum diagnosis contra curtum circuitum ad terram referuntur in nivello moduli.
Demonstrare statum localem channelli et gruppi.
Indicatores virides ostendunt statum output et indicatur ruber SF identificat errorem gruppi.
Official Specifications
| Suppeditatio oneris nominalis 2L+. | 24 V DC |
|---|---|
| Maxima attractio currentis electronicae. | 30 mA ex 2L+ sine onere et 30 mA ex bus dorsalis 3.3 V |
| Dissipatio Energiae Typica | 2 W |
| Spatium Adressarum Output | 1 octetum maximum |
| Limites currentis output | 0.5 A per canalibus; 4 A totalis per gruppus usque ad 55 °C in omnibus positionibus montandi |
| Typical Short-Circuit Response Threshold | 0,7 A |
| Limite tensionis clausurae pro oneribus inductivis | 2L+ minus 47 V |
| Maxima onus lampadis | 5 w |
| Onus resistentia | 48 Ω ad 4 kΩ |
| Minima tensio output in statu alto | 2L+ minus 0.8 V |
| Maximum OFF-State Residual Current | 0,5 mA |
| Maxima frequentia commutandi oneris resistivi | 100 Hz |
| Maxima frequentia commutandi oneris inductivi | 0.5 Hz |
| Maximum frequency of lamp-load switching | 1 Hz |
| Maxima Longitudo Cavi Campi | 30 m pro cable cum scuto vel sine scuto |
| Tensio Probae Isolationis | 707 V DC, type test |
| Dispositio isolationis output | Nulla isolatio inter canales; isolatio inter canales et bus dorsalem |
| Indicatores Locales | Rubra indicatrix SF erroris gruppi et virides indicatores status output digitalis |
| Dimensiones (L × H × D) | 45 × 130 × 35 mm |
| Pondus Approximatum | 140 g |
Quaestiones Frequenter Rogatae
Can two outputs of 6ES7142-4BF00-0AA0 be paralleled to increase the load current?
Parallel operation is not permitted for increasing current capacity.
How fast can 6ES7142-4BF00-0AA0 switch an inductive load?
Frequentia maxima commutandi pro onere inductivo est 0.5 Hz.
Does 6ES7142-4BF00-0AA0 identify short circuits by individual diagnostic channel?
Short circuits from outputs to ground are diagnosed module by module rather than as individual channel diagnostic messages.
Is the field connection module included with 6ES7142-4BF00-0AA0?
The bus module is included, but the compatible I/O connection module must be ordered separately.
How long may a field cable connected to 6ES7142-4BF00-0AA0 be?
The maximum field-cable length is 30 m for either shielded or unshielded cable.
Can all outputs of 6ES7142-4BF00-0AA0 carry their rated current at the same time?
The outputs may each carry 0.5 A within the 4 A group limit up to 55 °C in all mounting positions.
Are the output channels of 6ES7142-4BF00-0AA0 galvanically isolated from each other?
The output channels share a potential, while isolation is provided between the channels and the backplane bus.