Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000

Pro SIEMENS

Pagina prima>Producta>Pro SIEMENS

Siemens SIMATIC ET 200iSP PS 24 V DC 6ES7138-7EA01-0AA0

Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Product Overview
  • Key Functions
  • Official Specifications
  • Quaestiones Frequenter Rogatae
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Producta commendata
Conspectus

SIEMENS SIMATIC ET 200iSP — intrinsically safe distributed-I/O power supply module

6ES7138-7EA01-0AA0 SIMATIC ET 200iSP PS 24 V DC

Siemens specifies this 24 V DC power supply module for ET 200iSP, with redundancy capability, galvanic isolation, and hazardous-area approvals.

Ad Primum Aspectum

Nota Siemens
Modellum 6ES7138-7EA01-0AA0
Typus Producti Intrinsically safe distributed-I/O power supply module
Functio principalis Supplies ET 200iSP stations from a 24 V DC source with galvanic isolation
Applicatio vel series compatibiles ET 200iSP stations in hazardous-area automation systems
Identificatio exacta. Match the complete 6ES7138-7EA01-0AA0 article number and SIMATIC ET 200iSP PS 24 V DC designation.
Technical configurationis Confirm the documented interfaces, supply, and installed accessories for the SIMATIC ET 200iSP PS 24 V DC.
Examinatio Datorum Projectus Conservare la rete approvata, il controllore o la configurazione HMI utilizzata nelle stazioni ET 200iSP nei sistemi di automazione per aree pericolose.
Product Overview

Siemens specifies this 24 V DC power supply module for ET 200iSP, with redundancy capability, galvanic isolation, and hazardous-area approvals.

La documentazione ufficiale di Siemens identifica il prodotto per le stazioni ET 200iSP nei sistemi di automazione per aree pericolose. La selezione e la messa in servizio devono seguire i valori elettrici, di interfaccia, di memoria, ambientali e meccanici indicati di seguito.

Focus ordinandi: confirmare numerum articuli integrum, configurationem hardware installatam, suppetias, interfacia, accessoria et data projectus servata antequam substituatur.
Key Functions

Alimentazione ET 200iSP

Il modulo fornisce alimentazione al backplane della stazione e agli apparecchi elettronici collegati.

Capacité de redondance

È supportata l'operazione ridondata per configurazioni orientate alla disponibilità.

Progettazione per aree pericolose

La costruzione certificata è destinata alle installazioni ET 200iSP in zone pericolose.

Official Specifications
Voltage input aestimatum 24 V DC
Intervallo ingressus permissum 19,2 ad 30 V CC
Protectio contra polaritatem inversam Ita
Maximus Correntis Ingressus 4 A
Currentia maxima emissa 5 A
Perditio potentiæ typica 20 W
Buffering del backplane Almeno 0,25 ms
Buffering del bus di alimentazione Almeno 0,25 ms
IM 152 CPU Buffering At least 15 ms
Capacité de redondance Ita
Indicator Status Ita
Diagnostic Readout Via IM 152
Primary-to-Secondary Isolation Ita
Supply-to-Electronics Isolation Ita
Tensio Probae Isolationis 600 V DC between supply and output
Aestimatio Protectionis IP30
Temperatura operativa −20 ad +70 °C
Dimensiones 60 x 190 x 136.5 mm
Pondus Approximatum 2.7 KG
Fons officialis: Siemens official technical documentation for 6ES7138-7EA01-0AA0 . Stockus commercialis, garantia et affirmationes de expeditione sunt conditiones venditoris.
Quaestiones Frequenter Rogatae

What DC input window is allowed for 6ES7138-7EA01-0AA0?

Ingressus potest variare ab 19,2 usque ad 30 V DC et protectionem contra inversionem polaritatis includit.

Num 6ES7138-7EA01-0AA0 in dispositione redundantis potentiae installari potest?

Ita, modulus operationem redundantem suportat.

Quanta currentis output 6ES7138-7EA01-0AA0 praebere potest?

Maxima currentis output est 5 A.

Quae buffering pro IM 152 CPU ex 6ES7138-7EA01-0AA0 disponibilis est?

Supples IM 152 CPU est buffered pro minimo 15 ms.

Ubi diagnostics pro 6ES7138-7EA01-0AA0 legi possunt?

Status et informationes diagnosticas per IM 152 legi possunt.

Num ingressus electricus a egressu in 6ES7138-7EA01-0AA0 separatus est?

Yes, primary and secondary circuits are galvanically isolated and tested at 600 V DC.

What cabinet space is required for 6ES7138-7EA01-0AA0?

Allow for dimensions of 60 x 190 x 136.5 mm and a mass of approximately 2.7 kg.

Compatibility & Ordering Notes
Before ordering 6ES7138-7EA01-0AA0: compare the complete Siemens article number and the installed hardware, interfaces, accessories and project data.

Compatibility Checklist for 6ES7138-7EA01-0AA0

  • Match SIMATIC ET 200iSP PS 24 V DC and the full article number character by character.
  • Verify permissible input range: 19.2 to 30 V DC.
  • Confirm typical power loss: 20 W.
  • Preserve the approved settings and connection records used in ET 200iSP stations in hazardous-area automation systems.
Hot Selling Models
STI-13110FR
22CX230NC2
BZME1-A50-BT
VAN-115/230AC-K8
SR2 A201BD
CTS-CAM-P60 V02 800-101373-02
RCM420-D-2
CC0493200
TDG-BR250
CU2008-0000
1100-0-4
WIS-50
MTL 4013
DB-526
X20AO4622

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.