Siemens 6ES7134-4JB51-0AB0 ET 200S RTD Analog Input Module

Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Hot Selling Models
  • Producta commendata
Conspectus
SIMATIC ET 200S

6ES7134-4JB51-0AB0 ET 200S RTD Analog Input Module

Compact RTD input module supporting four two-wire channels or two three-/four-wire channels for Pt100, Ni100 and resistance measurement.

Ad Primum Aspectum

Nota Siemens
Modellum 6ES7134-4JB51-0AB0
Typus Producti 2/4 AI RTD Standard electronics module
Functio principalis Temperature and resistance measurement
Applicatio Pt100 and Ni100 sensor acquisition in ET 200S

Flexible RTD wiring

Connect four sensors in two-wire form or two sensors using three- or four-wire measurement.

Intervalia Resistance

Measure resistance over the 0–150 Ω, 0–300 Ω or 0–600 Ω ranges.

Measurement Diagnostics

Wire-break and range diagnostics, together with the SF LED, help identify sensor-circuit faults.

Product Overview

6ES7134-4JB51-0AB0 portat signales de resistentia-temperatura et de resistentia ad stationem ET 200S in modulo electronicum latum 15 mm.

Caracteristicae standard et climaticae pro Pt100 et Ni100 sunt seligibiles, et filtratio digitalis configurabilis adiuvat adaptationem lectionum ad responsionem processus.

Focus ordinandi: Selige characteristicam sensoris et modum connexions simul, quia connexiones tri- et quadri-filares numerum intrationum disponibilium ad duo reducunt.
Key Functions

Flexible RTD wiring

Connect four sensors in two-wire form or two sensors using three- or four-wire measurement.

Intervalia Resistance

Measure resistance over the 0–150 Ω, 0–300 Ω or 0–600 Ω ranges.

Measurement Diagnostics

Wire-break and range diagnostics, together with the SF LED, help identify sensor-circuit faults.

Official Specifications
Supplicatio oneris 24 V DC ab modulo potentiae
Maxima consumptio alimentationis 30 mA ab L+; 10 mA ab dorso 3.3 V
Perditio potentiæ typica 0,6 W
Spatium Adressarum Input maxime 8 octeta
Capacitas Connexionis Intrationis 4 canales in forma bi-filari; 2 canales in forma tri- vel quadri-filari
Intervalia Resistance 0–150 Ω, 0–300 Ω et 0–600 Ω
Mensurae Current 1,67 mA typice
Resistentia input 2 000 kΩ
Resolutio cum signo 16 bita pro Pt100/Ni100; 14 bita ad 150 Ω; 15 bita ad 300/600 Ω
Tempus Integrationis 16.7 aut 20 ms
Tempus conversionis per canalem 66 vel 80 ms, cum tempore addito pro experimento interrupturae fili
Frequenties pro rejectione interference 50 aut 60 Hz
Lissage numérique Nula, parva, media et magna; factores temporis cycli: 1, 4, 32 et 64
RTD Error Limits ±0,4 % ad 25 °C; ±0,6 % per ambitum temperaturarum operationis
Maximum Shielded Sensor Cable 200 m
Tensio Probae Isolationis 500 V DC
Dimensiones et pondus approximatum 15 × 81 × 52 mm; 40 g
Quaestiones Frequenter Rogatae

Can 6ES7134-4JB51-0AB0 measure four three-wire Pt100 sensors?

Three- or four-wire wiring provides two input channels, while four channels are available with two-wire connections.

Can I select a climatic Pt100 characteristic on 6ES7134-4JB51-0AB0?

Pt100 and Ni100 characteristics are selectable in both standard and climatic ranges.

Which resistance ranges can I configure on 6ES7134-4JB51-0AB0?

The available resistance ranges are 0–150 Ω, 0–300 Ω and 0–600 Ω.

How can I smooth a fluctuating reading on 6ES7134-4JB51-0AB0?

Filtrum digitale offert nullum, parvum, medium et magnum levigatum cum factoribus 1, 4, 32 et 64 temporis cycli.

Num 6ES7134-4JB51-0AB0 potest sensoris interruptae connexionem agnoscere?

Diagnostica interruptae connexionis disponibilia sunt simul cum diagnostica erroris in gruppo et diagnostica superflui vel subflui.

Quousque cables RTD scutati ad 6ES7134-4JB51-0AB0 extendi possunt?

Cables sensorum scutata usque ad 200 m longa esse possunt.

Num canales sensorum 6ES7134-4JB51-0AB0 ab invicem isolati sunt?

Canales unum gruppus potentialis partimur, dum isolatio a bus dorsalis et ab alimentatione L+ praebetur.

Compatibility & Ordering Notes
Antequam 6ES7134-4JB51-0AB0 ordinatur: Selige characteristicam sensoris et modum connexions simul, quia connexiones tri- et quadri-filares numerum intrationum disponibilium ad duo reducunt.

Antequam Installatio

  • Configura proprietates standard Pt100 aut Ni100 aut proprietates climaticas ut cum sensoribus installatis congruant.
  • Duos canales ad circuitus sensorum trium aut quattuor filorum assigna.
  • Permitte tempus conversionis additivum cum diagnosticis interruptus fili activis.
  • Tene cursus sensorum scutatorum infra 200 m et utere supply module potestatis electa.
Hot Selling Models
3RT2024-1BB44
ACT20M-CI-CO-S 1175980000
6-PE
VQZ3121B-5Y1-02-Q
BES516615PS1S11500.3
7FR50
MS6-LR-3/8-D8-KD-WR
DG500UG-3
03 3511.052.003
C9900K667
EPZ-06S-T-B03
5SY4620-7
DSM02.1-FW FWC-DSM2.1-C11-03V03-MS
DSM02.1-FW FWC-DSM2.1-ASE-02V04-MS
60-11z/V

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.