Siemens 6ES7134-4JB50-0AB0 SIMATIC ET 200S Duo-canalis RTD Modulus Normalis

Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Hot Selling Models
  • Producta commendata
Conspectus
Siemens SIMATIC ET 200S

6ES7134-4JB50-0AB0 SIMATIC ET 200S Duo-Canalis RTD Standard Module

Modulus RTD duo-canalis pro mensuram Pt100, Ni100 et 150/300/600 Ω, cum integratione et levigatione digitali selectoribus.

Ad Primum Aspectum

Nota Siemens
Modellum 6ES7134-4JB50-0AB0
Typus Producti Modulus electronicus analogus RTD
Functio principalis Mensura temperaturae et resistentiae
Applicatio ET 200S I/O distributus

Mensura directa RTD

Curvae Pt100 et Ni100 linearizari possunt in modulo.

Selectable filtering

integrationes 50/60 Hz et quattuor positiones levigationis adaptationem responsionis mensurae praebent.

Acquisitio quattuor-filorum

Connesiones quattuor-filorum vias mensurae a via correntis excitatricis separant.

Product Overview

6ES7134-4JB50-0AB0 mensurat duos canales RTD aut resistentiae in modulo electronico ET 200S 15 mm. Characteristicae temperaturarum Pt100 et Ni100 adiuvantur simul cum intervallis resistentiae 150 Ω, 300 Ω et 600 Ω.

Converter integrativus praebet suppressionem frequentialis interfectionis selectabilem et levigationem digitalem. Ingressus a bus dorsalis et ab alimentatione oneris separantur, dum utriusque canalium mensurationis eadem potentialis copia condividitur.

Focus ordinandi: Adaptare characteristiciam Pt100/Ni100, intervallum mensurationis, modulum terminalis et dispositionem connexionis bi-, tri- vel quadri-filarem.
Key Functions

Linearizare signa RTD

Characteristicae Pt100 et Ni100 configurabiles resistentiam in valores temperaturae convertunt.

Filtrare rumorem mensurationis

integratio 50/60 Hz et quattuor gradus levigationis digitalis responsionem adaptant.

Reportare defectus mensurationis

LED rubra SF pro errore gruppi et diagnostics legibilia adiuvant inspectionem defectuum.

Official Specifications
Canali Ingressus 2
Characteristicae RTD Pt100 et Ni100, cum linearisation parametrabilis
Intervalla mensurae resistentiae 150 Ω, 300 Ω aut 600 Ω
Resistentia minima ad introitum mensurae 2 MΩ
Alimentatio oneris nominalis 24 V DC ab modulo potentiae
Currens excitatrix RTD Circa 1.5 mA, tutela contra curtum circuitum
Maximum Load-Supply Current 30 mA
Dissipatio Energiae Typica 0,6 W
Maxima Longitudo Cavi Scutati 200 m
Longitudo datorum parametrorum 4 octetis
Resolutio cum superlimitatione Pt100/Ni100: 15 bit plus signum; 150 Ω: 14 bit; 300/600 Ω: 15 bit
Tempus Integrationis 16.7 ms ad rejectionem 60 Hz; 20 ms ad rejectionem 50 Hz
Tempus conversionis per canalem 110 ms ad 60 Hz; 130 ms ad 50 Hz
Constantes temporales pro levigatione digitali 1, 4, 64 aut 128 vicibus temporis cycli moduli
Isolatio Electrica Canalia isolata ab arcula dorsali et L+; nulla isolatio inter canalia
Differentia potentialis permittenda ad punctum terrae centrale 75 V DC / 60 V AC ex MANA
Testis voltagii isolationis 500 V DC
Limites erroris referentes ad intervallum intrantis Operativus ±0,6 %; basicus ad 25 °C ±0,4 %
Dimensiones 15 × 81 × 52 mm (L × A × P), tota compositio pendet a modulo terminali
Pondus Approximatum 40 g
Quaestiones Frequenter Rogatae

Quam characteristicam RTD configurare debeam in 6ES7134-4JB50-0AB0?

Elige characteristicam Pt100 aut Ni100 ut conveniat sensori coniuncto.

Do two-wire or three-wire connections to 6ES7134-4JB50-0AB0 eliminate lead-resistance error?

The line resistances are included in the measurement with two-wire and three-wire connections.

How does the mains-rejection setting affect conversion on 6ES7134-4JB50-0AB0?

Per-channel conversion takes 110 ms at 60 Hz rejection or 130 ms at 50 Hz rejection.

How can I smooth a fluctuating value from 6ES7134-4JB50-0AB0?

Choose one of the four digital-filter settings with time constants of 1, 4, 64 or 128 module cycle times.

Are the two measurement channels of 6ES7134-4JB50-0AB0 isolated from each other?

They share a potential group while remaining isolated from the backplane bus and load supply.

What is the shielded sensor-cable limit for 6ES7134-4JB50-0AB0?

The permitted shielded cable length is up to 200 m.

Quomodo possum errorem gruppi in 6ES7134-4JB50-0AB0 agnoscere?

Rubra LED SF indicat errorem gruppi et informationes diagnosticas ex modulo legi possunt.

Compatibility & Ordering Notes
Antequam 6ES7134-4JB50-0AB0 ordinatur: Retine modulum standardem 4JB50, selige exactam characteristicam RTD et intervallum, et serva dispositionem connexionum inter modulum terminalis et filos necnon parametres filtrorum.

Index compatibilitatis pro 6ES7134-4JB50-0AB0

  • Adaptare ad Pt100 aut Ni100 et ad intervallum resistentiae electum.
  • Verifica dispositionem moduli terminalis et filorum sensoris.
  • Admitte resistentiam filorum mensuratae in connexionibus duofilaris aut trifilaris.
  • Selige integrationem 50/60 Hz et gradum levigationis requisitum.
  • Mantene cables sensorum scutati infra 200 m.
Hot Selling Models
6ES7221-1BF32-0XB0
ISC-IAC-6
E2025UHR
ESX10-103-DC24V-6A
FBG11B
100MBAUD MOD.R911307946-GA1
WRF07PTD 0000000481335
6ES7122-1BB00-0AA0
F39-100-B0TG/30
PKZM4-50
ma1.3b-20/PSEN
8186-88680-0000000
MXS16-30 0.15-0.7
5SH3535
ZK1090-3100-3100

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.