Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000

Pro SIEMENS

Pagina prima>Producta>Pro SIEMENS

Siemens 6ES7134-4JB00-0AB0 SIMATIC ET 200S 2AI Thermocouple Input Module

Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Hot Selling Models
  • Producta commendata
Conspectus
SIMATIC ET 200S

6ES7134-4JB00-0AB0 SIMATIC ET 200S 2AI Thermocouple Input Module

Two-channel 15 mm ET 200S thermocouple module with ±80 mV input, external reference-junction compensation and configurable smoothing.

Ad Primum Aspectum

Nota Siemens
Modellum 6ES7134-4JB00-0AB0
Typus Producti Thermocouple analog input module
Functio principalis Acquisition de thermocouples et de millivolts
Applicatio ET 200S temperature-measurement stations

Thermocouple linearization

Types B, E, J, K, L, N, R, S and T are supported for temperature acquisition in Celsius.

Selectable interference rejection

Integratio conversio adiuvat praefinitas 50 Hz aut 60 Hz rejectiones frequentialis retis.

Functiones diagnosticas et lenificantes

Detectio overflow, underflow, interruptio fili thermocoupli et lenificatio selectabilis adiuvent valores processus stabiles.

Product Overview

6ES7134-4JB00-0AB0 acquirit duo signa thermocoupli aut millivolt in statione ET 200S.

Modulus linearizat typum thermocoupli supportatum in gradibus Celsius, praebet functiones diagnosticas configurabiles et utitur externa cassa compensationis pro singula iunctura referentiae thermocoupli.

Focus ordinandi: Adaptare typum thermocoupli, compensationem externam iunctionis referentiae, calefactum scutatum et modulum terminalis stationis 15 mm.
Key Functions

Thermocouple linearization

Types B, E, J, K, L, N, R, S and T are supported for temperature acquisition in Celsius.

Selectable interference rejection

Integratio conversio adiuvat praefinitas 50 Hz aut 60 Hz rejectiones frequentialis retis.

Functiones diagnosticas et lenificantes

Detectio overflow, underflow, interruptio fili thermocoupli et lenificatio selectabilis adiuvent valores processus stabiles.

Official Specifications
Numerus canalium analogicorum 2
Intervalum millivolt et resolutio ±80 mV; 15 bita plus signum
Genera Thermocupularum B, E, J, K, L, N, R, S et T
Unitas temperaturae Gradus Celsius
Compensatio iunctionis referentiae Cassette compensationis externus per canalum; nulla compensatio interna
Nominalis suppletio 24 V DC ab modulo potentiae; protectio contra inversionem polaritatis
Currens Alimentaria 30 mA maximum ex L+; 10 mA maximum ex 3.3 V dorso-plano
Perditio potentiæ typica 0,6 W
Spatium Adressarum Input 4 octetis
Resistentia input 1 MΩ
Limitatio permanentis tensionis intrantis 10 V
Maximus Cabelus Scutatus 50 m
Constitutio integrationis 16.7 ms pro 60 Hz; 20 ms pro 50 Hz
Conversio Tempus 55 ms ad 60 Hz; 65 ms ad 50 Hz; examen interrupti fili addit 20 ms
Factores lenificationis Nullus: 1; parvus: 4; medius: 32; magnus: 64 cycli conversionis
Limites erroris Operativus ±0.6%; basicus ±0.4% ad 25°C
Wire-Break Diagnostics Supported for thermocouple inputs
Isolatio From backplane and L+; not between channels; 500 V DC test
Dimensiones 15 × 81 × 52 mm (L × A × P)
Pondus Approximatum 40 g
Quaestiones Frequenter Rogatae

Does 6ES7134-4JB00-0AB0 provide internal cold-junction compensation?

Each thermocouple channel requires an external compensation box because internal reference-junction compensation is not provided.

Can 6ES7134-4JB00-0AB0 return thermocouple values directly in Fahrenheit?

Thermocouple values are provided in degrees Celsius.

How does wire-break monitoring affect the conversion time of 6ES7134-4JB00-0AB0?

Enabling the wire-break check adds 20 ms to the conversion time.

Can I use the wire-break function of 6ES7134-4JB00-0AB0 for every millivolt input?

The specified wire-break diagnostic applies to thermocouple inputs.

Quomodo tempus integrationis in 6ES7134-4JB00-0AB0 eligere debeat?

Elige 20 ms pro rejectione 50 Hz aut 16,7 ms pro rejectione 60 Hz.

Quam multum lenitionis ad signum turbatum in 6ES7134-4JB00-0AB0 applicare licet?

Factores lenitionis seligibiles sunt unus, quattuor, triginta duo aut sexaginta quattuor cycli conversionis.

Quousque ducere licet ductum sensoris scutatum ad 6ES7134-4JB00-0AB0?

Longitudo maxima scutatae cavi signi est 50 m.

Compatibility & Ordering Notes
Antequam 6ES7134-4JB00-0AB0 ordinatur: Adaptare typum thermocoupli, compensationem externam iunctionis referentiae, calefactum scutatum et modulum terminalis stationis 15 mm.

Antequam Installatio

  • Configura rectum thermocoppulae vel intervallum millivoltorum pro singulis canalibus.
  • Praebeto compensationem iunctionis referentiae externae, quam connexio thermocoppulae requirit.
  • Elige parametra integrationis et lenitionis ut conveniant ambiente retis electrici et responsioni processus.
  • Utere cavis signorum sub 50 m et dispositio terminalis ET 200S congruens.
Hot Selling Models
XC7 CFW500-SFY2
ESR5-NO-31-230VAC
SV9612.000
F82G-2GD-AP1
R82G-2LU-RFG
BCD7224-3-5-1-2
3RV1021-4BA15 3RV1901-1E
P1KH012 1003529
1302490111
1200870585
2-31/UKH 0201388
3RV1321-1AC10
EL300-850
GS28CCD 0714-59
GS28CC 6391-59

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.