Siemens 6EP4346-7RB00-0AX0 SITOP RED1200 redundancy module
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Provide two suitable DC supplies and size the load so the redundant supply arrangement meets the required operating condition.
- Allow for the approximately 0.6 V module drop when setting the supply voltage.
- Mount on a 35 mm DIN rail with 45 mm ventilation clearance above and below the module.
- Keep the connected circuits within the 10–58 V DC input range and the 20 A output limit.
6EP4346-7RB00-0AX0 SITOP RED1200 Redundancy Module
Compactum modulum redundantiae pro duobus subministris usque ad 10 A singulis, cum subministro communi 20 A et intervallo nominali systematis 12–48 V DC.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6EP4346-7RB00-0AX0 |
| Typus Producti | Modulus redundantiae subministrationis DC |
| Functio principalis | Separatio subministrationum DC parallelarum |
| Applicatio | Systemata industrialia subministrationis DC redundantia |
Separatio ex duobus fontibus
Duae introitus subministrationis potentiae, singulae usque ad 10 A, alimentant unum subministrum DC commune per modulum redundantiae.
Latum intervallum operationis DC
Intervallum operationis 10–58 V in introitu amplectitur systemata subministrationis DC nominalia a 12 usque ad 48 V.
Instrumentum-adaptabilis armarium electricum
Terminalia electrica ad impulsionem et corpus angustum in raile DIN favent compactis copiis electricis redundantibus.
Product Overview
6EP4346-7RB00-0AX0 separat duo continua directa (DC) alimenta, ut dispositio redundans possit onerare onus commune sine directa coniunctione outputorum fontium.
RED1200 tractat systema DC nominale 12–48 V cum usque ad 20 A in outputu et utitur terminalibus ad impulsionem in custodia raile DIN latitudinis 35 mm.
Key Functions
Separatio ex duobus fontibus
Duae introitus subministrationis potentiae, singulae usque ad 10 A, alimentant unum subministrum DC commune per modulum redundantiae.
Latum intervallum operationis DC
Intervallum operationis 10–58 V in introitu amplectitur systemata subministrationis DC nominalia a 12 usque ad 48 V.
Instrumentum-adaptabilis armarium electricum
Terminalia electrica ad impulsionem et corpus angustum in raile DIN favent compactis copiis electricis redundantibus.
Official Specifications
| Intervalum systematis DC nominale | 12–48 V DC |
|---|---|
| Tensio operativa intrantis | 10–58 V DC |
| Currentes intrantis et extrantis | Duo intrantes usque ad 10 A singuli; extrans usque ad 20 A |
| Decrementum tensionis extrantis typicum | Approximāte 0.6 V sub intrātū |
| Adūstātiō Voltāgis Exīsūs | Non adiustābilis |
| Efficientia typica | 97.5% |
| Potentiae amissiō ad plēnum onus | 12 W typicē ad 24 V / 20 A |
| Potentiae amissiō sine onus | 0.1 W maximum |
| Constructiō electrica | Sine isolatiōne inter intrātum et extrātum; classis protectiōnis III |
| Ambiens Operativa | −40 ad +70°C cum convectiōne naturalī |
| Ambiens de stockage et de transport | −40 ad +85°C |
| Humiditas relativa | 5–95%, non condensans |
| Eniraj kaj eliraj terminaloj | Conexiones por inserción para conductores de 0.2–10 mm² |
| Gradus praesidium | IP20 |
| Dimensiones et Pondera | 35 × 135 × 125 mm (An × Al × Pr); 0.47 kg |
| Altura de instalación requerida | 225 mm, incluyendo 45 mm de espacio libre arriba y abajo |
| Spatium laterale | 0 mm |
| Rail de montage | riel DIN de 35 × 7.5 mm o 35 × 15 mm conforme a EN 60715 |
Quaestiones Frequenter Rogatae
¿Puede el modelo 6EP4346-7RB00-0AX0 conectar dos fuentes de 10 A a una carga común?
El módulo acepta dos entradas calificadas hasta 10 A cada una y proporciona una salida común calificada hasta 20 A.
¿Qué caída de tensión debo considerar para el modelo 6EP4346-7RB00-0AX0 en un sistema de 24 V?
Considere aproximadamente 0.6 V de caída de tensión entre la fuente de entrada y la salida de carga.
¿Mantendrá el modelo 6EP4346-7RB00-0AX0 la carga durante la pérdida simultánea de ambas fuentes?
Modulus redundantia separavit supplitus sed non praebet conservationem energiae ad retinendum dum ambo fontes amittuntur.
Num possum tensionem exirem in 6EP4346-7RB00-0AX0 mutare?
Tensio exirens non est mutabilis et sequitur tensionem inirem minus cadum tensionis in modulo.
Quantum spatii verticalis pro ventilatione requirit 6EP4346-7RB00-0AX0?
Permitte 45 mm supra et 45 mm infra corpus 135 mm, pro altitudine totali installationis 225 mm.
Quae magnitudines filorum ad terminales potentiae 6EP4346-7RB00-0AX0 conveniunt?
Terminales inpulsivae inirentis et exirentis admittunt conductores a 0,2 usque ad 10 mm².
Num 6EP4346-7RB00-0AX0 directe in suppeditatione AC uti potest?
Modulus operatur cum inpulsibus DC ab 10 usque ad 58 V et exigit externas suppeditationes potentiae DC.