Conspectus
- Coniungere singula positiva fontis ad suum introitum attributum et utrumque negativum ad referentiam Gnd.
- Utere duobus modulis pro redundantibus dispositionibus fontis 30 A vel 40 A.
- Munire super rilum DIN 35 × 15 mm vel 35 × 7.5 mm cum terminalibus deorsum.
- Relinquare spatium 50 mm supra et infra.
- Pro applicationibus Ex, praebere installationem cum protectione IP54.
- Constituere limitem supervisionis ad aptandum destinatum fontem 24 V.
6EP1961-3BA20 SITOP Modular Redundancy Module
Modulus diodorum pro alimentationibus stabilis 24 V, cum supervisione tensionis intrantis regolabili et contactu commutationis flottante.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6EP1961-3BA20 |
| Typus Producti | Modulus pro redundanta alimentatio electrica |
| Functio principalis | Separat duas alimentationes in unam distributionem communem ad onus |
| Applicatio | Distributio redundantis electricae DC industrialis |
Iter redundantis supply
Una alimentatio residua onus sustentat si altera deficiat.
Voltage Supervision
Potentiometrum limitem supervisionis a 20 usque ad 25 V constituit.
Integratio in armario
Montatio in raeda DIN et refrigeratio naturalis installationem in tabula adiuvant.
Product Overview
6EP1961-3BA20 combinat duos stabilizatos 24 V potentias per diodum decoupling ad providendum redundantem oneris subministrationem.
Indicatio LED et flottans contactus rellais referunt conditionem tensionis intrantis, dum terminalia separata In 24V-1 et In 24V-2 connectunt duas originis subministrationes.
Key Functions
Onus subministratum per diodum decouplatum
Exirens communis subministrat onus ab utraque subministratione coniuncta, cum approximata cadente tensione diodi de 0.5 V.
Adiustabilis indicatio defectus
Thres-hold monitoris tensionis adiustabilis est inter 20–25 V, cum viridis et rubris indicationibus status et flottante contactu commutationis.
Dispositiones redundantes altioris currentis
Duo moduli requiruntur ubi duae subministrationes notatae sunt 30 A vel 40 A, cum uno modulo attributo uni subministrationi et duobus eius intrantibus interconectis.
Official Specifications
| Voltage input aestimatum | 24 V DC |
|---|---|
| Campus operativus intrantis | 22–28,8 V DC |
| Tensio Egressus | Voltatura input minus approximative 0,5 V |
| Interval currientis exitus | 0–40 A total |
| Reglaj de prag pentru monitorizare | 20 V ±0,5 V până la 25 V ±0,5 V |
| Contactus Significativus | Contact de comutare flotant, 6 A la 240 V AC |
| Indicazioni di stato | Verde: ambele intrări deasupra pragului; roșu: cel puțin o intrare sub prag |
| Temperatura operativa | 0–60 °C |
| Temperatura servandi et transportandi | −25 ad +85 °C |
| Categoria climatica | 3K3 conform EN 60721-3, fără condensare |
| Refrigerans | Naturale refrigerium per aerem |
| Gradus praesidium | IP20 conform IEC 529 |
| Electrical Safety | Clasa I conform IEC 536; SELV conform EN 60950 |
| Intervalum conductoris terminalis potentiae | 0,33–10 mm² |
| Torque de serrage du terminal d’alimentation | 1,2 N·m |
| Plage de conducteurs pour le terminal de signalisation | 0.5–2.5 mm² |
| Torque de serrage du terminal de signalisation | 0,5–0,6 N·m |
| Ponderis netum | 1,0 kg |
Quaestiones Frequenter Rogatae
Un module 6EP1961-3BA20 peut-il relier deux alimentations électriques de 20 A ?
Un module permet de constituer une configuration redondante pour deux alimentations stabilisées de 24 V, chacune pouvant débiter jusqu’à 20 A.
Comment connecter deux alimentations de 40 A via un module 6EP1961-3BA20 ?
Utiliser deux modules de redondance, affecter un module à chaque alimentation et relier entre elles les deux bornes d’entrée de chaque module.
Cur est voltatio post 6EP1961-3BA20 minor quam valor praefinitus suppetitionis?
Iter diodi minuit voltationem exirentem per approximative 0,5 V respectu voltationis intrantis.
Quomodo punctum allarmis in 6EP1961-3BA20 configuro?
Regula potentiometrum ut limen voltationis intrantis inter 20 et 25 V eligas.
Quid significat LED rubra in 6EP1961-3BA20?
Indicatio rubra significat quod saltem una voltatio intrans est infra limen commutationis electum.
Quantum spatii ventilationis 6EP1961-3BA20 requirit?
Modulum verticaliter monta, cum terminales in parte inferiori, et spatium liberum minimum 50 mm super et infra relinque.
Quomodo calem oneris ab 6EP1961-3BA20 dimensio habere debeat?
Conductor exirens ita dimensio habere debet ut currentem maximum combinatum utriusque suppetitionis electricae coniunctae ferre possit.