- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Selector intervalli introitus ante applicationem supply AC regendus est.
- Praebere protectionem pro alimentatore aptam ad dispositionem unius vel duarum phasium et ad currentem initiationis.
- Servare spatium vacuum 50 mm supra et infra corpus et applicare reductionem pro altis temperaturis ut requiritur.
- Eligere characteristicam supercarricandi et inspicere currentem initiationis oneris antequam distributio directa committatur.
6EP1334-3BA00 SITOP PSU200M 24 V 10 A Power Supply
SITOP modular supply delivering 24 V DC at 10 A, with selectable wide-range AC input and configurable overload behavior.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6EP1334-3BA00 |
| Typus Producti | Stabilized DIN-rail power supply |
| Functio principalis | Regulated 24 V DC supply for industrial control loads |
| Applicatio | Control cabinets with single- or two-phase AC supply |
Wide AC input selection
The input selector supports 120–230 V and 230–500 V nominal supply ranges with corresponding wide operating ranges.
Adjustable DC output
The 24 V output can be adjusted to 28.8 V using the potentiometer for the planned DC distribution arrangement.
Selectable overload response
The supply offers constant-current behavior or latching shutdown, with separate output, overload and shutdown LEDs.
Product Overview
6EP1334-3BA00 Provides a stabilized, isolated 24 V DC output rated at 10 A for industrial cabinet loads.
Selectable AC input ranges cover single- and two-phase supply arrangements, while output adjustment and switchable overload behavior support integration into the control power distribution.
Key Functions
Wide AC input selection
The input selector supports 120–230 V and 230–500 V nominal supply ranges with corresponding wide operating ranges.
Adjustable DC output
The 24 V output can be adjusted to 28.8 V using the potentiometer for the planned DC distribution arrangement.
Selectable overload response
The supply offers constant-current behavior or latching shutdown, with separate output, overload and shutdown LEDs.
Official Specifications
| Intervalia nominalia ingressus AC | 120–230 V or 230–500 V; selector switch |
|---|---|
| Intervalia permittenda ingressus AC | 85–264 V aut 176–550 V |
| Input frequency | 47–63 Hz |
| Uscita CC nominale | 24 V, 10 A, 240 W |
| Tensio exiens regolabilis | 24–28,8 V |
| Undulatio residua maxima | 50 mV |
| Maxima tensio outputus | 200 mV |
| Minimum mains bridging | 25 ms at 120/230 V and rated output current |
| Efficientia typica | 87% |
| Typical Power Loss at Rated Load | 36 v |
| Maxima Currus Inrumpens | 35 A ad 25 °C |
| Comportamentum Sub Supercarico | Approximately 12 A constant current or latching shutdown |
| Short-circuit current boost | Typice 30 A pro 25 ms durante operatione |
| Operatio Parallelis | Usque ad 2 unitates pro aucta potentia outputus |
| Gradus praesidium | IP20; classe de protectio I |
| Conexiones Electrificae | Terminalia vitarum, 0.2–2.5 mm² |
| Spatium ventilationis necessarium | 50 mm above and below |
| Montatio | Rota DIN 35 mm secundum EN 60715 |
| Dimensiones (L × H × D) | 90 × 125 × 125 mm |
| Ponderis netum | 1.4 KG |
Quaestiones Frequenter Rogatae
Num 6EP1334-3BA00 ex alimentatione biphasea 400 V operare potest?
Superior gamma intrantis sustinet 230 usque ad 500 V nominalis AC, si selector et protectio alimenti bipolare recte ordinantur.
Num output 6EP1334-3BA00 supra 24 V augeri potest?
Tensio output variari potest ab 24 usque ad 28.8 V per potentiometrum.
Quam spatium liberum circa 6EP1334-3BA00 requiritur?
Reservare oportet minimum 50 mm supra et infra corpus pro ventilatione.
Num duae unitates 6EP1334-3BA00 parallelae coniungi possunt ad maiorem currentem?
Usque ad duas unitates parallelae coniungi possunt ad augendam potestatem exirentem, si apta dispositio operativa utatur.
Cur 6EP1334-3BA00 post supercarrum manet clausum?
Electa supercarrum characteristicum potest exirentem retinere clausam, non autem operationem in currente constante servare.
Quod indicium in 6EP1334-3BA00 normalem directae currentis exirentem ostendit?
Viridis LED 24 V OK normalem exirentis operationem indicat.
Quam magnam conductoris dimensionem ad 6EP1334-3BA00 coniungere licet?
Terminales vitreae ad introitum et exirentem conductores a 0,2 usque ad 2,5 mm² accipiunt.