- Conspectus
- Product Overview
- Key Functions
- Official Specifications
- Quaestiones Frequenter Rogatae
- Compatibility & Ordering Notes
- Hot Selling Models
- Producta commendata
Conspectus
SIEMENS · TELEPERM XP
6DP1360-8BA TELEPERM XP FUM 360 Modulus Output Binary Securus
TELEPERM XP FUM 360 est modulus functionis output binary securus cum 24 output controller pro accoplatione relay 24 V DC, indicatione output in facie anteriori et subsidio pro dispositionibus redundantibus.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6DP1360-8BA |
| Typus Producti | Modulus functionis output binary securus |
| Functio principalis | Provides monitored 24 V DC controller outputs for relay coupling in TELEPERM XP safety applications |
| Applicatio vel series compatibiles | TELEPERM XP systems engineered for FUM 360 output functions and redundant use |
Identificatio exacta.
Match 6DP1360-8BA character by character and confirm the complete TELEPERM XP FUM 360 Fail-Safe Binary Output Module designation.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
TELEPERM XP FUM 360 est modulus functionis output binary securus cum 24 output controller pro accoplatione relay 24 V DC, indicatione output in facie anteriori et subsidio pro dispositionibus redundantibus.
Provides the FUM 360 binary output function for safety-related TELEPERM XP control tasks. Twenty-four controller outputs are rated for 24 V DC relay-coupling circuits. Front-panel indicators provide direct output-state observation during commissioning and service.
Key Functions
Fail-Safe Output Function
Provides the FUM 360 binary output function for safety-related TELEPERM XP control tasks.
Relay-Coupling Outputs
Twenty-four controller outputs are rated for 24 V DC relay-coupling circuits.
Visible Channel State
Indikatoria frontalis panelis praebent observationem directam status outputus dum in commissionem ducitur et dum servitium praestatur.
Official Specifications
| Designatio Moduli | FUM 360 |
|---|---|
| Familia Systematis | TELEPERM XP |
| Signal Direction | Emissiones binariae |
| Salus Function | Modulus outputus fail-safe |
| Outputus controlleris | 24 |
| Tensio Egressus | 24 V DC |
| Output Current | 120 mA per outputum controlleris |
| Onus typicum | Relais copulantia |
| Indicatio status outputus | LEDs panelis frontalis |
| Applicatio redundans | Supportata |
| Formatum Moduli | Modulus functionis TELEPERM XP in insertum |
Quaestiones Frequenter Rogatae
What type of field load is intended for 6DP1360-8BA?
Use compatible 24 V DC coupling relays within the specified output-current limit.
How many binary outputs are provided by 6DP1360-8BA?
The module provides twenty-four controller outputs.
Can 6DP1360-8BA be used in a redundant safety arrangement?
Yes; the module is specified for supported redundant TELEPERM XP applications.
How can an engineer see the state of an output on 6DP1360-8BA?
The corresponding front-panel LED indicates the controller-output state.
What must be checked before wiring a replacement 6DP1360-8BA?
Verify every terminal assignment, relay-coil rating, 24 V DC supply reference and safety-channel allocation.
Should 6DP1360-8BA be exchanged while the safety loop is active?
No; isolate the affected function according to the approved plant safety procedure before replacement.
What should be tested after installing 6DP1360-8BA?
Perform the authorized proof test for output switching, feedback, diagnostics and redundancy response.
Compatibility & Ordering Notes
Index Compatibilitatis
- Use only in a TELEPERM XP configuration that explicitly specifies the FUM 360 function.
- Match every output to the recorded relay and safety-channel assignment.
- Commission the replacement under the plant-approved fail-safe test and authorization process.