- Conspectus
- Product Overview
- Key Functions
- Official Specifications
- Quaestiones Frequenter Rogatae
- Compatibility & Ordering Notes
- Hot Selling Models
- Producta commendata
Conspectus
Siemens · SIMATIC ET 200SP HA / SPPA-T3000
6DL1135-6TF00-0EH1 SIMATIC ET 200SP HA AQ 8xI HART Analog Output Module
The AQ 8xI HART HA module offers eight analog current outputs with HART communication, 24 V DC operation, 16-bit current representation, channel diagnostics, and redundant use on an M1 terminal block for SPPA-T3000 applications.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6DL1135-6TF00-0EH1 |
| Typus Producti | Eight-channel HART analog current output module |
| Functio principalis | Outputs precision current signals with HART communication and per-channel diagnostics |
| Applicatio vel series compatibiles | SPPA-T3000 ET 200SP HA stations using H1 or M1 terminal blocks |
Identificatio exacta.
Match 6DL1135-6TF00-0EH1 character by character and confirm the complete SIMATIC ET 200SP HA AQ 8xI HART Analog Output Module designation.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
The AQ 8xI HART HA module offers eight analog current outputs with HART communication, 24 V DC operation, 16-bit current representation, channel diagnostics, and redundant use on an M1 terminal block for SPPA-T3000 applications.
Eight channels provide current control for compatible field actuators with HART communication. The module is configurable in supported SPPA-T3000 engineering environments from the documented baseline. Channel diagnostics and M1 terminal-block redundancy support high-availability process applications.
Key Functions
Eight Precision Current Outputs
Eight channels provide current control for compatible field actuators with HART communication.
SPPA-T3000 Integration
The module is configurable in supported SPPA-T3000 engineering environments from the documented baseline.
Diagnostic and Redundant Operation
Channel diagnostics and M1 terminal-block redundancy support high-availability process applications.
Official Specifications
| Typus Producti | AQ 8xI HART HA |
|---|---|
| Versio Firmamentalis | V1.0, updateable |
| Egressus Analogici | 8 current channels |
| Intervalla output | 0–10 mA, 0–20 mA et 4–20 mA |
| representatio 4–20 mA | 16 bit inclusu signo |
| Tensio nominalis supplicii | 24 V DC |
| Permissum Supplicationis Intervallum | 19,2 ad 28,8 V CC |
| Consumptio Electrica Typica | 230 mA ad 8 × 20 mA et 750 Ω |
| Maxima Consumptio Electrica | 350 mA ad 8 × 24 mA et 750 Ω |
| Perditio potentiæ typica | 3.2 W |
| Maxima Resistentia Onus | 750 Ω |
| Maxima Longitudo Cavi Scutati | 1000 m |
| Accuratio basica ad 25 °C | ±0.1% |
| Terminales coniunctionis | H1 and M1 |
| Redundantia | Supportatus cum blocco terminali M1 |
| SPPA-T3000 Integration | V8.0 vel posterior |
| Temperatura operationis, horizontalis | −40 ad +70 °C |
Quaestiones Frequenter Rogatae
Which engineering system baseline supports 6DL1135-6TF00-0EH1?
Use a supported SPPA-T3000 configuration from version 8.0 onward.
Which terminal blocks can be used with 6DL1135-6TF00-0EH1?
The module supports H1 and M1 terminal blocks, with M1 required for redundancy.
What current ranges are available on 6DL1135-6TF00-0EH1?
Configure 0 to 10 mA, 0 to 20 mA or 4 to 20 mA for each supported output channel.
Can 6DL1135-6TF00-0EH1 report a wire break or short circuit?
Yes; wire-break and short-circuit diagnostics are available by channel.
What supply range is permitted for 6DL1135-6TF00-0EH1?
Provide 19.2 to 28.8 V DC with correct polarity.
How long can a shielded field cable be for 6DL1135-6TF00-0EH1?
The specified maximum shielded cable length is 1000 metres.
What should be saved before replacing 6DL1135-6TF00-0EH1?
Preserve channel ranges, HART data, diagnostics, substitute values, redundancy assignment and the SPPA-T3000 project.
Compatibility & Ordering Notes
Index Compatibilitatis
- Use the module in the supported SPPA-T3000 hardware catalog and preserve the existing engineering baseline.
- Choose the M1 terminal block only where the approved redundant arrangement is required.
- Verify all actuator loads, HART settings and channel diagnostics before commissioning.