Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000

Siemens 6DD1606-2AC0 SIMADYN D PT20G Processor Module

Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Hot Selling Models
  • Producta commendata
Conspectus

SIMADYN D • PT20G PROCESSOR

6DD1606-2AC0 SIMADYN D PT20G Processor Module

PT20G processor module for technological control and SITOR line-commutated converter applications.

Ad Primum Aspectum

Nota Siemens
Modellum 6DD1606-2AC0
Typus Producti Modulus Processoris PT20G
Functio principalis Technological open- and closed-loop control with converter gating
Series Compatible SIMADYN D; SITOR converter sets

Processor platform

16-bit 80C186 CPU operating at 20 MHz with real-time SIMADYN D control.

Ingressus et Egressus Integri

Analog, binary, speed sensing and serial interfaces on the PT20G assembly.

SITOR connection

50-pin converter interface supplies thyristor gating signals.

Product Overview

6DD1606-2AC0 is a SIMADYN D PT20G processor module for technological open- and closed-loop control, arithmetic and drive-related functions. It combines a PT20 basic board with a TG1 submodule.

The module supports line-commutated SITOR converters through its dedicated interface, while analog, binary, speed sensing and serial connections serve the installed control application.

Focus ordinandi: Confirm the existing SIMADYN D rack, MS4x program memory, interface arrangement and SITOR wiring before replacement.
Key Functions

Real-time control

The 80C186 processor runs the SIMADYN D operating system and processes configured technological and drive control tasks.

Integrated signal processing

Seven analog inputs, four analog outputs, 24 binary inputs, 16 binary outputs and two speed sensing inputs connect to field signals.

Converter control and diagnostics

Interfacs X8 praebet signa SITOR gating; display septem-segmentorum in fronte indicat codicem moduli aut codicem fault.

Official Specifications
Articulus / modulus 6DD1606-2AC0 / PT20G
Processor 16-bit 80C186, 20 MHz
RAM onboard 64 KB, bufferata bateriis ab alimentatione
Interfacs memoriae programmatum Modulus MS4x insertibilis in X50
INPUTUS ANALOGI 7 canales
Intervalum Analogum Input ±10 V
Resolutio Ingressus Analogici 11 bit plus signum
Egressus Analogici 4 canales
Intervalum Analogum Output ±10 V
Ingressus binarii 24 canales, tensio nominalis 24 V DC
Emissiones binariae 16 canales
Currente nominalis de output binari 50 mA per output
Ingressus pro sensu de velocitate 2 canales, usque ad 100 kHz
Output pro alimentatio de encoder 14 V, usque ad 100 mA
Interfacies Seriales 2 (X01: TTY vel RS-232; X02: RS-485)
Interfascia SITOR conector de 50 pins X8
Output pro gating SITOR 12 impulsum outputus
Operans ambientium temperatus 0 ad 55 °C
Dimensiones Tabulae 233.4 × 220 mm; latitudo 40.28 mm
Pondus Approximatum 1 kg
Quaestiones Frequenter Rogatae

Quod systema utitur 6DD1606-2AC0?

Est modus processoris PT20G pro systemate digitali de controllo SIMADYN D.

Quae sunt hardware processus intra 6DD1606-2AC0?

Confectio utitur processore 16-bit 80C186 operante ad 20 MHz.

Quam memoriam programmatum 6DD1606-2AC0 utitur?

Accipit modulum memoriam programmatum MS4x SIMADYN D in slot X50.

Potestne 6DD1606-2AC0 regere convertorem SITOR?

Yes, the PT20G has a dedicated 50-pin SITOR interface for converter gating.

How many analog signals can the 6DD1606-2AC0 connect?

The module provides seven analog inputs and four analog outputs.

Which serial connections are available on the 6DD1606-2AC0?

The module provides two serial interfaces with X01 configured for TTY or RS-232 and X02 for RS-458.

What should be checked before replacing the 6DD1606-2AC0?

Check the SIMADYN D rack, program memory, interface modules, external wiring, and SITOR connection against the existing installation.

Compatibility & Ordering Notes
Before ordering the 6DD1606-2AC0: Match the PT20G assembly and program configuration to the installed SIMADYN D rack and connected SITOR equipment.

Replacement Checklist

  • Confirm the exact PT20G order number and the existing rack slot arrangement.
  • Transferre aut configurare memoriam programmatum MS4x approbatam et configurationem applicationis.
  • Verificare connexiones serialis X01/X02, ingressus/egressus analogicos et binarios, et connexionem sensus velocitatis.
  • Depotentiare cuneum antequam tabulam insere, deinde verificare connexionem X8 SITOR et diagnosticos.
Hot Selling Models
3RV1011-1JA10
8MR2131-4A
140MC2TB40
3VU1300-1NJ00
5SY6102-7
DSN16100P
SS5YJ3S4106M5FQ
DGS385 VA 952084 + DG MOD385 VA 952029
WT34B410 1019229
R-1/4 231605
P31R-122
3RP2511-1AW30
YF2A15-C60UB5M2A15 2096006
MC-10 1609801044
cs1.1p 540050

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.