- Verificare supplitum trifasatum monitoratum et comportamentum defectus/ordinis phasium requisitum ante connexiones circuitus de regula.
- Dimensio onerum contactuum utendo rating AC-15 vel DC-13 applicabile, non limitem currentis thermalis.
- Utere ambitum conductorum specificatum, dispositionem terminalium et protectionem fusibilis relais output.
- Siemens indicat 3UG5512-2BR20 ut successor praefertus; verificare totam compatibilitatem electricam et mechanicam ante substitutionem.
3UG4512-2BR20 SIRIUS Relay for Monitoring Phase Failure and Sequence
Analog three-phase monitor for 160–690 V AC, with automatic reset, two changeover contacts, and removable spring-loaded terminals.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 3UG4512-2BR20 |
| Typus Producti | Three-phase line monitoring relay |
| Functio principalis | Phase-loss and phase-sequence detection |
| Applicatio | Three-phase machine supply monitoring |
Phase-loss detection
The relay detects failure of a phase in the monitored three-phase supply.
Recognition of phase sequence
The phase order function enables the control system to respond to an incorrect phase sequence.
Automatic reset and contact outputs
Two changeover contacts provide the monitoring output, with automatic RESET specified for this variant.
Product Overview
3UG4512-2BR20 is a SIRIUS line monitoring relay for phase failure and phase sequence on three-phase AC systems. It provides two changeover contacts and uses a spring-loaded connection system with removable terminals.
The relay is intended for the two specified phase-monitoring functions. Its automatic reset, maximum 450 ms response time, and slim snap-on housing facilitate integration of phase status into machine control circuits.
Key Functions
Phase-loss detection
The relay detects failure of a phase in the monitored three-phase supply.
Recognition of phase sequence
The phase order function enables the control system to respond to an incorrect phase sequence.
Automatic reset and contact outputs
Two changeover contacts provide the monitoring output, with automatic RESET specified for this variant.
Official Specifications
| Monitored supply | 3 × 160–690 V AC, 50–60 Hz |
|---|---|
| Contactus Exirentes | 2 contactus commutantes |
| Modus Restituendi | Lorem Reset |
| Temps de réponse maximal | 450 ms |
| Maxima currentis thermicae per contactus | 5 A |
| Classis contactuum AC-15 | 3 A ad 250 V aut 400 V AC |
| DC-13 contactus valoris | 1 A ad 24 V DC |
| Minimum switching load | 5 mA ad 17 V |
| Fusibilis relais outputus valoris | 4 A DIAZED fusibilis linkus |
| Tensionis insulatio evaluata | 690 V, super tensionis categoria III, pollutionis gradus 3 |
| Tensione impulsiva subita evaluata | 6 kV |
| Relativa repetitio accuratia | 1% |
| Typica contactus durabilitas | 10 milliones mechanicorum cyclorum; 100 000 electricorum cyclorum ad AC-15, 230 V |
| Systema terminalis | Terminalēs removibiles cum mōlībus |
| Capacitas conductoris | 2 × 0.25–1.5 mm²; AWG 24–16 |
| Gradus Protectionis Anterioris | IP20 |
| Temperatura operationis / conservationis | −25 ad +60 °C / −40 ad +85 °C |
| Altitudo Installationis Maxima | 2 000 m supra mare |
| Dimensiones et pondus netum | 22.5 × 94 × 91 mm (lat × alt × prof); 128.19 g |
| Montatio | Adfixiō per clīpsum; quaelibet positio montāgiī |
Quaestiones Frequenter Rogatae
Num 3UG4512-2BR20 detegit ordinem phasium inrectum?
Ita; cognitio ordinis phasium est una ex duābus functionibus monitoriae specificātīs.
Num 3UG4512-2BR20 etiam praebet detectionem subvoltāgis aut asymmetriae phasium?
Minime; functionēs enumerātae comprehendunt defectum phasis et ordinem phasium, sed non detectionem subvoltāgis, supravoltāgis aut asymmetriae.
Is reset on 3UG4512-2BR20 manual or automatic?
The specified reset function is auto-RESET.
What is the maximum monitoring response time of 3UG4512-2BR20?
The maximum monitoring response time is 450 ms.
How much can an output contact of 3UG4512-2BR20 switch at 400 V AC?
The AC-15 contact rating at 400 V AC is 3 A.
Which terminal style is supplied on 3UG4512-2BR20?
The relay uses removable spring-loaded terminals, with capacity for two 0.25–1.5 mm² conductors at the specified connections.
Is 3UG4512-2BR20 designated for a safety function?
No; the relay is not suitable for a safety function.