Siemens 3UA59 40-1J 3UA59 Thermal Overload Relay 6.3–10 A
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Configura advectionem ad currentem nominalem oneris realis intra 6.3–10 A.
- Utere combinatione contactoris certificata a fabricante compatibili aut dispositione montis separati approbata.
- Elige reinitiationem manualem H aut automaticam A pro sequentia controlis machinae.
- Utere conductores cupri intra sectiones transversas specificatas et applica momenta torsionis separata pro terminalibus principalibus et auxiliariis.
- Praebeto protectionem coordinatam contra curtum circuitum in circuitu principali et protectionem circuitus auxiliaris specificatam.
- Pro onere monofasico, connecte omnes tres vias currentis principalis in serie.
3UA59 40-1J 3UA59 Relay thermicus supervacuitatis 6,3–10 A
Relay supervacuitatis 3UA59 cum intervallo regolandi currentis 6,3–10 A, repositio manuella aut automatica, pulsator experimenti, et unus contactus controlis normaliter apertus plus unus normaliter clausus.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 3UA59 40-1J |
| Typus Producti | Relay thermicus supervacuitatis regolabilis |
| Functio principalis | Protectio contra supervacuitatem motoris et defectum fasis |
| Applicatio | Compatibilis cum coniunctionibus motor-contactorum aut montatione separata |
Regulatio currentis oneris
Intervallo 1J regulatur ab 6,3 A usque ad 10 A.
Reinicia selectio
Le buttono caeruleo seligit reset manuale H vel automaticum A.
Testus circuitus de controllo
Le buttono testis rubrum aperit le contactu NC e cludit le contactu NO.
Product Overview
3UA59 40-1J es le relais thermic de supercarga 3UA59 de typo aperte con le codice de construction 40 e le gamma de ajustamento de currente 1J de 6,3–10 A.
Le relais sensibile a fallo de fase es compensate pro temperatura ambiental e provide un selection de reset, simulation de supercarga per le buttono de testo e contactus de controllo pro le circuito de controllo del motor.
Key Functions
Ajusta le protection al currente del carga
Le scala de ajustamento es ajustate al currente nominal del carga intra le gamma de 6,3–10 A de iste articulo.
Selige reset manual o automatic
The blue reset button makes the relay ready after tripping, with H for manual resetting and A for automatic resetting.
Test the control contacts and read the trip indication
Pressing the red test button opens the NC contact and closes the NO contact, while the green trip pin indicates a trip in manual-reset mode.
Official Specifications
| Adjustable Current Range | 6.3–10 A |
|---|---|
| Main-Circuit Rated Insulation Voltage | 690 V AC |
| Auxiliary-Contact Arrangement | 1 NA + 1 NC |
| Ambient Compensation | Ambient-temperature compensated |
| Reset Modes | H manual and A automatic; supplied in H mode |
| Gradus praesidium | IP20; tutelus ad digitos secundum DIN VDE 0106 Pars 100 |
| Licet ambientium temperatus | −25 ad +55 °C |
| Sectio transversa conductoris principalis | Solidus vel torquatus: 1.5–25 mm²; torquatus subtiliter cum ferrula: 1–16 mm² |
| Sectio transversa conductoris auxiliaris | Solidus: 2 × 0.5–1 aut 2 × 1–2.5 mm²; torquatus subtiliter cum ferrula: 2 × 0.5–1 aut 2 × 0.75–2.5 mm² |
| Vitae terminalium et momentum retinens | Principalis: M5, 2.5–3.0 N·m; auxiliaris: M3.5, 0.8–1.4 N·m |
| Pondera nominalia auxiliaria AC-15 | 2 A ad 24 V; 1.5 A ad 60 V; 1.25 A ad 125 V; 1.15 A ad 230 V; 1.1 A ad 400 V; 0.8 A ad 690 V |
| Pondera nominalia auxiliaria DC-13 | 2 A ad 24 V; 0,5 A ad 60 V; 0,3 A ad 110 V; 0,2 A ad 220 V |
| Optiones pro montu separato | raium 35 mm in forma capitis aut fixatio per clavos in superficie plana |
| Protectio auxiliaris contra curtum circuitum | fusibilis NH/NEOZED/DIAZED de 6 A, fusibilis DIAZED rapidus de 10 A, aut interruptor automaticus characteristicis-C de 3 A |
Quaestiones Frequenter Rogatae
Quomodo regulare debet dial currentis in 3UA59 40-1J pro initio operationis?
Regula scala ad currentem nominalem oneris intra intervallum regulandi 6,3–10 A.
Quomodo mutare 3UA59 40-1J ab repositione manuella ad automaticam?
Premere il pulsante blu e ruotarlo in senso antiorario da H ad A.
Che cosa accade ai contatti di comando quando si preme il pulsante rosso su 3UA59 40-1J?
Il contatto NC si apre e il contatto NO si chiude per simulare un intervento per sovraccarico.
Perché non compare l'indicazione verde di intervento quando 3UA59 40-1J è impostato su A?
L'indicazione verde sporgente di intervento funziona nell'impostazione H di ripristino manuale, non nell'impostazione A di ripristino automatico.
È possibile montare 3UA59 40-1J separatamente dal contattore?
La configurazione di montaggio separato supporta una guida a cappello di 35 mm o un fissaggio con viti su una superficie piana.
Che cosa si deve fare con i tre percorsi principali di corrente di 3UA59 40-1J per un carico monofase?
Collegare tutti e tre i percorsi principali di corrente in serie per il carico monofase.
Quale coppia di serraggio si deve utilizzare per collegare i morsetti principali e ausiliari di 3UA59 40-1J?
Stringe terminales principales M5 ad 2.5–3.0 N·m et terminales auxiliaries M3.5 ad 0.8–1.4 N·m.