3SU1401-1BB20-3AA0 SIRIUS ACT Red LED Module 24 V AC/DC
A front-plate-mounted red LED module with an integrated light source, spring-loaded terminals and a rated 24 V AC/DC supply.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 3SU1401-1BB20-3AA0 |
| Typus Producti | LED illumination module |
| Functio principalis | Red control-panel indication |
| Applicatio | SIRIUS ACT front-panel assemblies |
Integrated red light source
The LED produces 450–1120 mcd light intensity for the selected signaling point.
Alimentatio contruli AC vel DC
Eadem modulus accipit tensionem nominalem 24 V DC vel 24 V AC ad 50 vel 60 Hz.
Coniunctio per terminalia molicula
Conductores flexibiles nudi et parati habent limites diversae sectionis transversae permisse.
Product Overview
3SU1401-1BB20-3AA0 addit illuminationem LED rubram integratam ad conformationem signali SIRIUS ACT in facie anterius.
Modulus terminalium molicularum montatur in parte posteriori supportis in positione centrali et operat ex alimentatione contruli 24 V AC/DC electa.
Key Functions
Illuminare punctum signali rubri electum
Fons lucis integratus praebet illuminationem rubram sine transformatoris lampadis separabilis.
Accipere tensionem contruli disponibilem
Operation at 24 V AC or DC supports common panel control supplies within the specified voltage tolerance.
Fit behind the panel holder
The narrow module attaches in the center mounting position on the rear of the SIRIUS ACT holder.
Official Specifications
| Tensione de alimentation nominal | 24 V AC a 50/60 Hz o 24 V DC |
|---|---|
| Permissible supply tolerance | −30% / +25% |
| Maxima Consumptio Electrica | 25 mA |
| Maxima Currus Inrumpens | 2 A |
| Tensionis insulatio evaluata | 320 V |
| Tensione impulsiva subita evaluata | 4 kV |
| Gradus Contaminations | 3 |
| Intensitas luminis | 450–1120 mcd |
| Vita de functionamento typical | 100,000 H |
| Electrica connectio | Terminales cum mola |
| Bare solid and finely stranded conductor range | 2 × (0.25–1.5 mm²) |
| Praeparatus subtiliter torquatus conductoris ambitus | 2 × (0.25–0.75 mm²) |
| Module Protection | Carcasa IP40; terminales IP20 |
| Operans ambientium temperatus | −25 ad +70 °C |
| Temperatura ambientalis servandae | −40 ad +80 °C |
| Operativus Relativus Umor | 10–95 %, sin condensación |
| Resistencia a golpes, IEC 60068-2-27 | 15 g, 11 ms half-sine pulse |
| Resistencia a vibraciones, IEC 60068-2-6 | 5 g over 10–500 Hz |
| Dimensiones (L × H × D) | 9.8 × 36 × 29.4 mm |
| Peso neto del módulo | 7 g |
Quaestiones Frequenter Rogatae
Ubi 3SU1401-1BB20-3AA0 adhaeret ad supportum tabulae anterioris?
Modulus LED montatur in facie posteriori supporti in positione centrali.
Num possum usare 3SU1401-1BB20-3AA0 ad illuminandum tabulam viridem?
Non, fons lucis incorporatus est ruber.
Num 3SU1401-1BB20-3AA0 requirit transformatorium lampadis separatum?
Non, hic modulus LED habet fontem lucis incorporatum et nullum transformatorium lampadis.
Quanta inductio commutativa debet outputus regulans permittre pro 3SU1401-1BB20-3AA0?
Apparatus commutativus debet admittere inductio maximam 2 A et etiam currentem operativam maximam 25 mA.
Num potest conductor flexibilis praeparatus 1,0 mm² connecti ad 3SU1401-1BB20-3AA0?
Non, conductores subtiliter intorti cum praeparatione extremitatis limitantur ad 0,75 mm².
Will 3SU1401-1BB20-3AA0 tolerate a control-supply voltage 20% below 24 V?
Yes, a 20% reduction lies within the specified negative operating-voltage tolerance of 30%.
Can 3SU1401-1BB20-3AA0 be installed where condensation is expected during operation?
No, condensation is not permitted within the specified operating environment.