Siemens 3RV2742-5GD10 SIRIUS S3 40 A Circuitus Interruptor Systematis Protegendi

Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Hot Selling Models
  • Producta commendata
Conspectus
SIRIUS 3RV2

3RV2742-5GD10 SIRIUS S3 40 A System-Protection Circuit Breaker

A size S3 system-protection breaker with a 40 A thermal release, 520 A magnetic trip and UL 489 approval.

Ad Primum Aspectum

Nota Siemens
Modellum 3RV2742-5GD10
Typus Producti Three-pole circuit breaker
Functio principalis Interrupting overload and short-circuit currents
Applicatio Industrial system and feeder protection

Interrupt abnormal currents

A 40 A thermal release is combined with a 520 A instantaneous magnetic trip.

Provide isolation functionality

The breaker supports disconnector functionality and is operated by a handle.

Fit industrial feeders

The S3 device uses main-circuit screw terminals and supports screw or 35 mm DIN-rail mounting.

Product Overview

3RV2742-5GD10 protects an AC system circuit using thermal overload and magnetic short-circuit releases.

The three-pole S3 device provides disconnector functionality and a handle indication, with optional auxiliary-switch expansion for control-panel integration.

Focus ordinandi: Match the 40 A rating and voltage-dependent breaking capacity to the protected system.
Key Functions

Interrupt abnormal currents

A 40 A thermal release is combined with a 520 A instantaneous magnetic trip.

Provide isolation functionality

The breaker supports disconnector functionality and is operated by a handle.

Fit industrial feeders

The S3 device uses main-circuit screw terminals and supports screw or 35 mm DIN-rail mounting.

Official Specifications
Rated Current and Thermal Release 40 A
Circuitus principalis 3-pole AC circuit; 50–60 Hz
Operans voltage range 20–600 V AC
Trip magneticus instantaneus 520 A
Icu ad 240 et 400 V AC 100 kA
ICs 100 kA ad 240 V AC; 50 kA ad 400 V AC
Capacitas interrumpendi UL 489 65 kA ad 480Y/277 V AC
Tensionis insulatio evaluata 1 000 V ad gradum pollutionis 3
Tensio Impulsus Tolerata 8 kV
Amissa Potentia ad Currum Nominalem 18 W totalis; 6 W per polus
Durabilitas contactus 25 000 cycli operationis mechanici et electrici typici
Protection IP20 anterius; IP00 terminalia
Intervalum Operativum et Compensatorium −20 ad +60 °C
Temperatura servandi et transportandi −50 ad +80 °C
Spatium Requisitum ad 400 V 90 mm supra et infra; 10 mm ad latera
Torque Terminalis Principale 4.5–6 N·m; clavus hexagonalis 4 mm
Altitudo Installationis Maxima 2,000 m
Dimensiones (L × H × D) 70 × 170 × 176 mm
Ponderis netum 2.196 kg
Quaestiones Frequenter Rogatae

Estne 3RV2742-5GD10 interruptor circuitus UL 489 pro protectione systematis?

Approbatur hoc instrumentum ut interruptor circuitus pro protectione systematis secundum UL 489 et CSA C22.2 No. 5.

Ad quam currentem magneticum liberatio 3RV2742-5GD10 respondet?

Instantanea interruptio contra curtum circuitum ad 520 A respondet.

Num 3RV2742-5GD10 detectionem defectus phaseos vel defectus ad terram praebet?

Hoc interruptor non praebet detectionem defectus phaseos vel defectus ad terram.

Num contactus auxiliares status ad 3RV2742-5GD10 addere possum?

Expansio commutatoris auxiliaris disponibilis est; tamen in dispositivo basico nulli contactus auxiliares NO, NC aut inversi sunt insiti.

Quam capacitatem interrumpendi ad 3RV2742-5GD10 in systemate 480Y/277 V utendam habeo?

Capacitas interrumpendi contra curtum circuitum secundum UL 489 ad 480Y/277 V AC est 65 kA.

Quanta spatium liberum circa 3RV2742-5GD10 ad 400 V necessarium est?

Spatium 90 mm supra et infra, atque 10 mm ad latera a partibus terratis vel vivis concedendum est.

Num terminalibus 3RV2742-5GD10 eadem tutela praebetur atque in parte anteriore?

Pars anterior est IP20, terminalibus IP00.

Compatibility & Ordering Notes
Antequam 3RV2742-5GD10 ordinatur: Match the 40 A rating and voltage-dependent breaking capacity to the protected system.

Antequam Installatio

  • Eligere interrumptricem pro actuaria tensione circuitus, 40 A onere continuo et corrente defectus disponibili.
  • Uti capacitatem interrumpendi applicabilem Icu, Ics aut UL 489 pro installatione.
  • Servare interstitia specificata et constringere vitarum principalium tornillos ad 4.5–6 N·m.
  • Commutatores auxiliares separatim specificare, ubi signa status requiruntur.
Hot Selling Models
TZ1LE024SEM4AS1
CTSM40L
WKN10/U BL/V0 57.510.0155.6
BMA040MDA0050
Allen-Bradley 140M-D8E-C16
3RT1026-1AL24
NCB40-FP-A2-P1-V1
XE020 71088
000-84060-0000000
13070-250
DBG60B-10 28229150.10.13
3321607
021-1BF00
OG0034 OGT-HB0A
MQDEC-830-12M23RA

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.