Siemens 3RB3016-1TB0 SIRIUS Electronicus Relais Suprachargi 4–16 A

Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Hot Selling Models
  • Producta commendata
Conspectus
SIRIUS 3RB3

3RB3016-1TB0 SIRIUS 4–16 A Electronic Overload Relay

A Class 10E electronic relay with a 4–16 A adjustment range, screw terminals, and selectable manual or automatic reset.

Ad Primum Aspectum

Nota Siemens
Modellum 3RB3016-1TB0
Typus Producti Electronic overload relay
Functio principalis Monitoring motor overload current
Applicatio Size S00 motor starter protection

Adjust overload protection

The electronic release uses Class 10E tripping with a 4–16 A current setting.

Coordinate trip and indication

One NC auxiliary contact disconnects the contactor and one NO contact provides tripped indication.

Fit the starter assembly

The S00 relay mounts on a contactor and provides screw connections with removable auxiliary/control terminals.

Product Overview

3RB3016-1TB0 provides three-pole current-dependent overload protection in a compact size S00 starter assembly.

The relay mounts on a compatible contactor and separates the contactor-disconnection signal from the auxiliary indication of a tripped condition.

Focus ordinandi: Set the response within the 4–16 A motor-current range and select the required reset mode.
Key Functions

Adjust overload protection

The electronic release uses Class 10E tripping with a 4–16 A current setting.

Coordinate trip and indication

One NC auxiliary contact disconnects the contactor and one NO contact provides tripped indication.

Fit the starter assembly

The S00 relay mounts on a contactor and provides screw connections with removable auxiliary/control terminals.

Official Specifications
Adaptatio currentis 4–16 A
Trip Characteristic Class 10E electronic release
Circuitus principalis 3 poli; current nominalis 16 A
Voltage operandi aestimatum Jusqu’à 690 V CA
Frequentia censita 50–60 Hz
Potentia Motoris ad 400 et 500 V 2,2–7,5 kW ad 50 Hz
Potentia Motoris ad 690 V 3–11 kW ad 50 Hz
Contactus auxiliares 1 contactus NC pro disconnectione contactoris et 1 contactus NO pro indicatione trip
Ratinges auxiliaries AC-15 4 A ad 24–125 V AC; 3 A ad 230 V AC
Ratinges auxiliaries DC-13 2 A ad 24 V; 0,55 A ad 60 V; 0,3 A ad 110–125 V; 0,11 A ad 220 V
Recovery Automaticum-Reset 3 minuta typica post trip propter onus nimium
Coordinatio Fusibilis Circuitus Principalis Typus 1: 50 A gG aut 60 A RK5; typus 2: 50 A gG aut 60 A J
Fusibile Circuitus Auxiliaris 6 A gG
Praestituta Potentia Amissa 1.1 W totalis; 0.37 W per polus
Par de torsion pro terminalibus 0.8–1.2 N·m pro visis principalibus et auxiliaribus
Intervalum Operativum et Compensatorium −25 usque ad +60 °C
Spatium laterale 6 mm ab partibus terrae et vivis
Tutela anterior IP20; tutus ad tactum digitorum ex parte anteriore
Dimensiones (L × H × D) 45 × 79 × 73 mm
Ponderis netum 0.219 kg
Quaestiones Frequenter Rogatae

Num 3RB3016-1TB0 ita deprimi potest ut ad motorem 3 A idoneus sit?

Minima correntis reglatio est 4 A; ergo motor 3 A infra huius rellais ambitum regulandi cadit.

Num 3RB3016-1TB0 post eventum supercarricaturae automato restitui potest?

Restitutio automata disponibilis est, cum tempore recuperationis typico trium minutorum.

Quomodo 3RB3016-1TB0 signum separatim praebet quod trip occurrerit?

Contactus auxiliaris normaliter apertus ad indicandum trip assignatus est.

Quae fusibilis in circuitu auxiliari 3RB3016-1TB0 requiritur?

The auxiliary switching circuit requires a 6 A gG fuse.

How much side clearance does 3RB3016-1TB0 need near grounded metal?

Keep 6 mm of clearance at the side from grounded or live parts.

Which screwdriver and torque should I use on 3RB3016-1TB0?

Use a Pozidriv PZ 2 screwdriver and tighten the main and auxiliary terminal screws to 0.8–1.2 N·m.

What UL full-load current applies to 3RB3016-1TB0 at 480 V or 600 V?

The specified full-load current for a three-phase AC motor is 16 A at both voltages.

Compatibility & Ordering Notes
Before ordering 3RB3016-1TB0: Set the response within the 4–16 A motor-current range and select the required reset mode.

Antequam Installatio

  • Use a compatible S00 contactor and adjust the response to the motor rated current.
  • Choose manual or automatic reset to match the machine restart sequence.
  • Elige el fusible del circuito principal especificado para la coordinación tipo 1 o tipo 2.
  • Mantén una separación lateral de 6 mm y el par de apriete especificado en los terminales de tornillo.
Hot Selling Models
WDU95N/120N
IB040BM46VD8
1.5/5-STF-3.81
D22-LD-EAK-10-20
X07V-K 1X1.5 4520111
MYH-5/3G-2.3-L-LED
ADN-63-10-APA
3RF2330-1AA24
DSNU25160PPVA
16A-aR
BS35II
R108561620
6ES5095-8MD01 6ES5375-1LA15