Siemens 3RA1903-0AB10 ET 200S TM-DS45-S31 Throughfeed Terminal Module
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Use the S31 arrangement for throughfeed and the S32 version where an infeed connection is required.
- Match the terminal base to the standard DS1-x direct starter.
- Install PE/N terminal blocks before connecting the starter terminal modules.
- Fit the specified caps to exposed power-bus contacts at the end of the load group.
3RA1903-0AB10 ET 200S TM-DS45-S31 Throughfeed Terminal Module
A TM-DS45-S31 terminal base for a standard direct starter, with screw connections and power-bus throughfeed rather than an infeed connection.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 3RA1903-0AB10 |
| Typus Producti | Motor-starter terminal module |
| Functio principalis | Mechanical and electrical integration of direct starters |
| Applicatio | ET 200S standard DS1-x starter stations |
Throughfeed arrangement
The S31 terminal module passes the power bus through the starter station.
Standard direct starter
The TM-DS45 base is assigned to the DS1-x standard direct-starter arrangement.
Prepare field wiring
Screw terminals allow prewiring before the starter electronics are fitted.
Product Overview
3RA1903-0AB10 provides the TM-DS45-S31 throughfeed terminal-base arrangement for an ET 200S standard direct starter. The module supports screw-terminal field wiring and passes the power bus onward without providing the supply-line infeed arrangement of the S32 version.
The power-bus rating and the starter-branch rating describe different current paths. The AUX1 conductor passes through without its own terminals, and the open power-bus contacts at the end of a load group require the specified protective caps.
Key Functions
Continue the power bus
The S31 module provides power-bus throughfeed without the S32 infeed connection.
Support prewired starter positions
Termināli cum vītīs permittunt praeparātiōnem conductōrum in locō antequam starter directus adiungitur.
Integrāre conductōrēs protectōrēs
Arrangementum terminalium-basis potest augērī cum idōneō blocco terminalium PE/N.
Official Specifications
| Tensio operātōria nominālis bus potentiae | 500 V AC |
|---|---|
| Tensionis insulatio evaluata | 690 V |
| Resistentia nominālis ad impulsum | 6 kV |
| Cūrrēns operātōria bus potentiae | 40 A pro arrangemente TM-DS45 |
| Frequēntia bus potentiae | 50/60 HZ |
| Līmes cūrrēntis rami starteris | 12 A pro arrangemente normalī DS1-x |
| Electrica connectio | Fistulae fixationis |
| Protectio anterius et regionis connexionis | IP20 in parte anteriori; IP00 in regione connexionis terminalis principalis potentiae |
| Dispositio conductoris AUX1 | Transmissio sine terminalibus |
| Dimensiones schematis | 51.9 × 264 × 119 mm generaliter (L × A × P); latitudo corporis moduli 44.9 mm |
| Ponderis netum | 348 g |
Quaestiones Frequenter Rogatae
Num 3RA1903-0AB10 uti potest ut modul us terminalis ad influxum bus potentiae?
Dispositio S31 praebet transmissionem, non autem connexionem influxus versionis S32.
Quale avviatore motore standard si adatta alla disposizione TM-DS45 del modello 3RA1903-0AB10?
Il modulo terminale è assegnato all’avviatore diretto standard ET 200S DS1-x.
Posso completare il cablaggio sul campo per il modello 3RA1903-0AB10 prima di installare l’avviatore?
La base con morsetti a vite consente il cablaggio preliminare prima dell’installazione dell’elettronica dell’avviatore.
La portata del bus di potenza da 40 A del modello 3RA1903-0AB10 descrive anche il suo ramo avviatore?
Il bus di alimentazione in serie ha una portata di 40 A, mentre il ramo avviatore diretto standard ha un limite di 12 A.
Il modello 3RA1903-0AB10 prevede morsetti dedicati per AUX1?
Il conduttore AUX1 transita senza morsetti.
Quale protezione è necessaria quando il modello 3RA1903-0AB10 è l’ultimo modulo terminale in un gruppo di carico?
Sigillare i contatti aperti del bus di potenza con i cappucci protettivi specificati prima della messa in servizio.
When should I install the PE/N terminal block for 3RA1903-0AB10?
Install the PE/N terminal block before connecting the motor-starter terminal modules.