Honeywell ControlEdge HC900 16-Canalis Input Analogus Nivelis Altus Modulus 900A16-0103
Produttore: Honeywell
Condición: Nuevo
Plazo de Entrega: En Stock
Origen: Estados Unidos
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Product Overview
- Key Functions
- Official Specifications
- Quaestiones Frequenter Rogatae
- Compatibility & Ordering Notes
- Hot Selling Models
- Producta commendata
Conspectus
Honeywell • ControlEdge HC900
900A16-0103 ControlEdge HC900 16-Channel High-Level Analog Input Module
The Honeywell ControlEdge HC900 high-level analog input module provides sixteen isolated, user-configurable voltage or current inputs with integrated shunts, diagnostics and field calibration.
Ad Primum Aspectum
| Nota | HONEYWELL |
|---|---|
| Modellum | 900A16-0103 |
| Typus Producti | Isolated 16-channel voltage and current analog input module |
| Functio principalis | Acquires sixteen high-level voltage or current signals with channel isolation, diagnostics and field calibration |
| Applicatio vel series compatibiles | ControlEdge HC900 systems using compatible racks, 36-terminal blocks or remote terminal panels |
Identificatio exacta.
Compare character by character with model 900A16-0103 and verify the full designation: ControlEdge HC900 16-Channel High-Level Analog Input Module.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
The Honeywell ControlEdge HC900 high-level analog input module provides sixteen isolated, user-configurable voltage or current inputs with integrated shunts, diagnostics and field calibration.
Each channel accepts a user-configured voltage or current range, with point-to-point and backplane isolation. Individual 250-ohm shunt resistors can be enabled via DIP switch for current inputs. Analog conversion is synchronized with controller execution, and all analog modules are processed in parallel.
Key Functions
Sixteen Isolated Inputs
Each channel accepts a user-configured voltage or current range, with point-to-point and backplane isolation.
Integrated Current Shunts
Individual 250-ohm shunt resistors can be enabled via DIP switch for current inputs.
Synchronized Acquisition
Analog conversion is synchronized with controller execution, and all analog modules are processed in parallel.
Official Specifications
| Canali Ingressus | 16 isolated |
|---|---|
| Genera Intrōdūctiōnum | Tensio et cursus |
| Impedantia Intrantis Voltaginis | Maior quam 1 MΩ |
| Impedantia Intrantis Currentis | 250 Ω |
| Isolatio Punctum-ad-Punctum | 400 V DC |
| Isolatio ad Logicam | 1 000 V DC |
| Reiectio Rumoris in Modo Serie | Maior quam 31 dB |
| Reiectio Rumoris Communis-Modi | Maior quam 90 dB ad 120 V AC |
| Accuratio Fabricae | ±0,1 % intervali |
| Praecisio Calibratiōnis in Campo | ±0.05% intervalli |
| Integrated Current Shunts | 16 × 250 Ω, activātum interruptōre DIP |
| Terminus necessarius | Euro-stīlus, 36 terminālia |
| Blox terminale compatibile | 900TCK-0200 |
| Tabula Terminalis Remōta Compatibilis | 900RTS-0001; duae per modulum |
| Cānus RTP Compatibilis | 900RTC-34xx |
| Dimensiones Moduli | 137 × 35.6 mm; altitūdō × latitūdō |
| Pondus Moduli | 397 g |
Quaestiones Frequenter Rogatae
Quae signa ad 900A16-0103 connexa esse possunt?
Configura singulos canales isolatos pro approbato alto voltagio vel intervallo currentis.
Quomodo inputus currentis in 900A16-0103 seligitur?
Activare shunt integratum 250-ohm canalis per aptam positionem interruptoris DIP.
Quod blocum terminalis cum 900A16-0103 utitur?
Utere compatibilem blocum terminalis Euro-stilum 36-terminalium et serva attributionem canalis ad terminalem.
Num 900A16-0103 tabulam terminalis remotam uti potest?
Ita; dispositio specificata duas tabulas terminalis remotas compatibiles et copiam cables congruentem utit.
Quae diagnosica in 900A16-0103 disponuntur?
Indicatores status identificant scansionem, canales coactos et conditiones diagnosticas moduli.
Quid servandum est antequam 900A16-0103 substituatur?
Registrare omnem intervallum canalium, scalationem, valorem failsafe, statum coactionis, calibratum et positionem interruptoris DIP.
Quid inspiciendum est post commissionem 900A16-0103?
Verificare omnes sedecim signales, isolationem, scalationem, selectionem current-shunt, calibratum et diagnostics moduli.
Compatibility & Ordering Notes
Index Compatibilitatis
- Utere apto armario HC900 et apparatu coniunctionis terminalis 36.
- Omnes interruptores shunt canalium currentis recte constituere.
- Restituere scalationem canalium, valorem failsafe et data calibrati antequam validatio loop perficiatur.