Locus originis: |
Suecia |
Nomen marcae: |
ABB |
Numerus exemplaris: |
AI895 3BSC690086R1 |
Particularia impaquetandi: |
Originales nova Officina Sigillata |
Tempus solutionis: |
5-7 dies |
Conditiones solutionis: |
T/T |
Vis Supplicandi: |
In stirpe |
Specificationes
|
Exemplum: |
AI895 3BSC690086R1 |
|
Typus: |
Modulus Ingressus Analogicus |
|
DIMENSIONES: |
4,5 × 10,5 × 12 cm |
|
Pondus: |
0.24 kg |
|
Genus Signali: |
Unipolaris, singulāris |
|
Intervalum Signorum: |
4–20 mA |
|
Numerus canalium: |
8 |
|
Supportus HART: |
Ita |
|
Supportus SOE: |
No |
|
Redundantia: |
No |
|
Alta Integritas: |
No |
|
Securitas Intrinseca: |
Ita |
|
Systema Mechanicum: |
S800 |
|
Resolutio: |
12-bit |
|
Isolatio: |
Singulae ex gruppo a terra isolatae |
|
Sub/Supra Limites: |
1,5 / 22 mA |
|
Exactitudo: |
Typicē 0,05 %, Māximē 0,1 % |
|
Derivatio thermica: |
Typicē 100 ppm/°C |
|
Filtrum Ingressus (tempus crescentiae 0–90%): |
20 ms |
|
Limitatio Currendi: |
Limitatio potestatis transmittentis incorporata |
|
CMRR (50/60 Hz): |
>80 dB |
|
NMRR (50/60 Hz): |
>10 dB |
|
Tensio isolans nominalis: |
50 V |
|
Tensio probatoria dielectrica: |
500 V AC |
|
Dissipatio Potentiae: |
4,75 W |
|
Consumptio currentis (+5 V Modulebus): |
Typice 130 mA |
|
Consumptio currentis (+24 V Externa): |
Typice 270 mA, Maxime <370 mA |
Descriptio
Modulus Analogus Input AI895 3BSC690086R1 directe interfacere potest cum transmitteribus duarum virarum; et, particulari coniunctione, etiam cum transmitteribus quattuor virarum interfaciens, sine amissione facultatis HART. Modulus Analogus Input AI895 octo canales habet. Modulus componentes protectionis Intrinsic Safety in singulis canalibus includit, ut ad instrumenta processus in locis periculosis connectantur, absque necessitate ulteriorum externorum instrumentorum. Singuli canales transmitterem processus duarum virarum alere et inspicere, necnon communicationem HART monitorare possunt. Cadere voltaticum in input currentis typice 3 V est, PTC inclusum. Suppeditatio transmitteris pro singulo canali saltem 15 V ad currentem circuitus 20 mA praebere potest, ut transmitteres processus Ex-certificati alantur, et in conditionibus supra oneris ad 23 mA limitatur.
TU890 et TU891 Compact MTU cum hoc modulo uti possunt et duos filos ad instrumenta processus sine terminalibus additis connectere permittunt. TU890 ad applicationes Ex, TU891 ad applicationes non-Ex.
Ambientia et Certificatio
|
Signum CE: |
Ita |
|
Tutela electrica: |
EN 61010-1, EN 61010-2-201 |
|
Loca Periculosa: |
ATEX/IECEx Zona 2 cum interfacie ad Zonam 0; cFMus C1 Divisio 2 / Zona 2 cum interfacie ad C1, C2, C3 Divisio 1 / Zonam 0 |
|
Certificatio maritima: |
ABS, BV, DNV, LR |
|
Operativa Temperatura: |
0 ad +55 °C (+32 ad +131 °F) |
|
Temperatura Storagii: |
-40 ad +70 °C (-40 ad +158 °F) |
|
Gradus Pollutionis: |
Gradus 2, IEC 60664-1 |
|
Protectio contra corrosionem: |
ISA-S71.04: G3 |
|
Humiditas relativa: |
5 ad 95 %, non condensans |
|
Maxima Temperatura Ambientis: |
55 °C (131 °F), pro montatura verticali in compactorum MTU 40 °C (104 °F) |
|
Classis protectionis: |
IP20 secundum IEC 60529 |
|
Conditiones Operationis Mechanicae: |
IEC/EN 61131-2 |
|
Compatibilitas Electromagnetica (EMC): |
EN 61000-6-4, EN 61000-6-2 |
|
Categoriae Supertensionum: |
IEC/EN 60664-1, EN 50178 |
|
Classis Instrumentorum: |
Classis I secundum IEC 61140 (protecta per terram) |
|
Conformatio RoHS: |
RoHS Unionis Europaeae, RoHS Emiratuum Arabum Unitorum, RoHS Sinensis |
|
Adimpletio directivae WEEE: |
DIRECTIVE/2012/19/EU |
Usus
Refineriae olei: accessus ad transmittentes pressionis et altitudinis in zonis inflammabilibus et explosivis (Zona 0/1).
Offshore plantae productionis olei: acquisitio signorum instrumentorum intrinsece sicurorum ad caput puteorum olei et gas et ad cisternas accumulationis.
Plantae additivarum chemicarum: transmissio fluxus et temperaturae in areis explosione prohibitis circa reactiva.
Plantae accipientes gas naturalem (LNG): monitorium instrumentorum intelligentium in armis descaricandi et in areis cisternarum accumulationis.
Plantae agrochimicae: integratio instrumentorum explosione prohibitorum in lineis productionis quae solventia inflammabilia involvunt.
Plantae fabricantes explosiva/pulveres: isolatio et transmissio sensorum intrinsece sicura in officinis productionis periculosissimis.
Characteristica et utilia
octo canales pro 4…20 mA, unipolares ingressus simplices.
Communicatio HART.
unus grex octo canalium a terra isolatorum.
Potestas et monitor pro transmittentibus duarum filarum certificatis Ex.
Ingressus analogici non retinentes energiam pro fontibus externe alimentatis.
Diagnosis
Diodae luminiscae anteriores: F(ault), R(un), W(arning), Tx (communicatio HART)
Supervisio: interna suppetitia processus
Compatibilitas
Uso cum MTU: TU890, TU891 aut TU891Z
Codex clavium: AE
FAQ
Q: Quid est AI895 3BSC690086R1?
A: Est modululus intrantis analogici.
Q: An coniungi potest ad transmittentem quattuor filarum?
A: Ita. Licet AI880A praecipue ad transmittentes duarum filarum designatus sit, ad instrumenta quattuor filarum etiam coniungi potest per methodos specificas connexiones (utendo suppetitia externa) dum manet functio communicationis HART.
Q: Estne modelus redundantis AI895 3BSC690086R1?
A: Redundantia non suffragatur. Modulus AI895 3BSC690086R1 ad applicationes non redundantes designatus est (Redundantia: Non). Si systema redundancy requirit, solutio moduli redundantis ex alia serie S800 seligenda est.
Q: Quomodo pretium et adstantia AI895 3BSC690086R1 investigantur?
A: Rogamus, ut Iohannem Yang pro venditionibus contacteris ad numerum +86-18150117685 aut citatio petatur.