Conspectus
Locus originis: |
USA |
Nomen marcae: |
Bently Nevada |
Numerus exemplaris: |
3500/45 140072-04 |
Particularia impaquetandi: |
Originales nova Officina Sigillata |
Tempus solutionis: |
5-7 dies |
Conditiones solutionis: |
T/T |
Vis Supplicandi: |
In stirpe |
Velox Detail
|
Requisita Spatii in Reticulo |
1 interstitium posterius plene altum |
|
Temperatura operativa |
−30°C ad +65°C (−22°F ad +150°F) |
|
Temperatura recondita |
-40°C ad +85°C (-40°F ad +185°F) |
|
Humiditas |
95% non condensans |
|
Signum |
Accipit ab uno ad quattuor signorum introitus |
|
Consumptio potentiae |
7,7 Vattus, ut solet, utendo Positione I/O |
|
Input impedimentum |
1 MΩ (introitus DC LVDT) 10 kΩ (introitus Proximitor vel RPT) 137 kΩ (introitus AC LVDT) 200 kΩ (introitus Potentiometri Rotatorii) |
|
Sensibilitas ad Impulsum |
3.94 mV/μm (100 mV/mil) aut 7.87 mV/μm (200 mV/mil) |
|
Dimensiones: |
24 × 25,5 × 2,5 cm |
|
Pondus: |
0.9kg |
Descriptio
The 3500/45 140072-04 Monitor Positionis ab Bently Nevada™ est instrumentum quattuor canalium ad systemata automationis destinatum, quod signa accipit e transductoribus proximitatis, transductoribus positionis rotativis (RPT), LVDT directa/alternata, et potentiometris rotativis. Singuli canales signa condicionant cum impedantiis intrantis 10 kΩ (Proximitor/RPT), 1 MΩ (LVDT directa), 137 kΩ (LVDT alternata), et 200 kΩ (potentiometer rotativum), praebentes sensibilitatem pro impulsum 3,94–7,87 mV/µm et sensibilitatem pro expansione differentiale 0,394–0,787 mV/µm. Per Software Configurationis Rack 3500 operatoribus programmantur monitoria positionis axialis, expansionis differentialis, duplicis rampae, expansionis casus, et positionis valvulae. 3500/45 140072-04 Monitor Positionis impulsus admonitiones et alarmas pro variabilibus mensuratis praebet, dum 7,7 W per canalium consumit operans in temperaturis ab −30°C ad +65°C. In uno completo retro slot rack montatus, hic monitor praecisas, real-time positionis datas pro automatione machinarum suppeditat, certus exactam mensuram et puncta programmata admonitionum intra ±0,33% typicam accuratiam plenae scalae.
Usus
Monitor Positionum Axialium et Thrust in Turbinibus
Uti 3500/45 140072-04 Monitor Positionis ad positiones axiales et thrust turbinum observandas, cum impedantia intrinseca Proximitoris 10 kΩ et sensibilitate thrust 3,94–7,87 mV/µm. Admonitiones constituere licet, cum mensurae thrust limina programmata excedunt.
Mensura Expansionis Differentialis in Scambiatoribus Caloris
The 3500/45 140072-04 Monitor Positionis condit signales DC LVDT ad 1 MΩ, generans signales expansionis differentialis cum sensibilitate 0,394–0,787 mV/µm. Admonitiones programmare licet ab 0 usque ad 100% plenae scalae ad observationem tensionis mechanicae.
Positiones Valvarum Regulatricum in Plantis Processualibus
The 3500/45 140072-04 Monitor Positionis monitorat potentiometra rotatoria cum impedantia intrantis 200 kΩ ad consequendam praecisionem ±0,33 % in mensuris positionis valvularum. Id permittit praecisum controllem automatizatum et notificationes de allarmibus.
Observa Expansiones Rampae Duplex in Compressoribus
Uti 3500/45 140072-04 Monitor Positionis ad comparandas expansiones rampae duplex per signales AC LVDT ad 137 kΩ, sublevans manutenationem praedictivam et notificationes de adaptationibus operativis.
Registra Expansionem Carchassis in Motoribus Magnis
The 3500/45 140072-04 Monitor Positionis mensurat signales expansionis carchassis, praebens data in tempore reali ad 7,7 W per canallem dum operatur a −30°C usque ad +65°C, id quod permittit adaptationes actionabiles in operationibus motorum.
Specificationes
|
Sensibilitas Incrementi Differentialis |
0,394 mV/μm (10 mV/mil) aut 0,787 mV/μm (20 mV/mil) |
|
Sensibilitas Incrementi Differentialis Gradualis |
0,394 V/mm (10 mV/mil), 0,787 V/mm (20 mV/mil), 3,937 V/mm (100 mV/mil), aut 7,874 V/mm (200 mV/mil) |
|
Impulsus et Incrementum Differentiale (Accuratio ) |
Intra ±0,33% valoris pleni, typice ±1% maximum |
|
Impulsus et Incrementum Differentiale (Responsio in Frequentia Filtrationis Directae ) |
−3 dB ad 1,2 Hz |
|
Impulsus et Incrementum Differentiale (Responsio frequentialis filtrī interstitiālis ) |
−3 dB ad 0,41 Hz |
|
Puncta constitūta allārmis |
Utere ōrnāmentō 3500 Rack Configuration Software ad constituenda puncta monitūs et perīculī pro valoribus directē mēnsūrātīs ā monitorē. Allārmae sunt adiūstābiles ab 0 usque ad 100 % plēnī scālae pro quōlibet valōre mēnsūrātō. Tamen, cum scāla plēna excedit ambitum trānsductōris, ambitus trānsductōris limitābit punctum constitūtum. |
|
Accuratio punctorum allarum |
Intra 0,13% valoris desiderati |
|
|
|
|
Accūrātia positīōnis vālvulae |
Intra ±0,33% valoris pleni, typice ±1% maximum |
|
Positīō vālvulae (responsiō frequentialis filtrī directī) |
−3 dB ad 1,2 Hz |
|
Positīō vālvulae (responsiō frequentialis filtrī interstitiālis) |
−3 dB ad 0,41 Hz |
Aliquam commodo
Tracta Plures Species Signorum in Uno Monitori
The 3500/45 140072-04 Monitor Positionis integrat quattuor canales qui sustinent Proximitores, RPT, DC/AC LVDTs, et potentiometra rotatoria, minuens spatium in armario et simplificans connexionem systematis.
Praebet Mensuras Allarum Quantificatas
Cum sensibilitate pro impulsum 3,94–7,87 mV/µm et sensibilitate pro expansione differentiale 0,394–0,787 mV/µm, 3500/45 140072-04 Monitor Positionis generat allarmes accuratos intra ±0,33 % typicum pleni scalae, certificans lectiones actionabiles.
Programma Alarum pro Singulis Variabilibus Mensuratis
The 3500/45 140072-04 Monitor Positionis permittit puncta admonitoria et periculosa ab 0 ad 100 % scalae plenae pro singula variabili, quae praecisam regulationem limium operationis faciunt.
Subsidium Mensurae in Tempore Reali et Responsionis Frequentiae
The 3500/45 140072-04 Monitor Positionis servat directam responsionem frequentiae filtrantis ad −3 dB ad 1,2 Hz et responsionem filtrantis interstitii ad −3 dB ad 0,41 Hz, quae continuam supervisionem systematum automationis praebet.