Conspectus
Locus originis: |
USA |
Nomen marcae: |
Bently Nevada |
Numerus modeli: |
330706-005-046-10-02-00 |
Particularia impaquetandi: |
Originales nova Officina Sigillata |
Tempus solutionis: |
5-7 dies |
Conditiones solutionis: |
T/T |
Vis Supplicandi: |
In stirpe |
Velox Detail
|
Optiones longitudinis cavi: |
1.0 metrum (3.3 pedes) |
|
Connectivus et Optio Cavi: |
Conector coaxialis ClickLoc miniatūrus |
|
Agendi Probatio Optio: |
Non opus est |
|
Filum Cassae Sondae: |
M10 x 1 fila |
|
Dimensiones: |
1.2x1.2x119cm |
|
Pondus: |
0.05KG |
Descriptio
The 330706-005-046-10-02-00 3300 XL 11 mm Sonde Montata Retroversum praebet īnputum 3,94 V/mm (100 mV/mil) ad praecīsa mēnsūra non contactūs vibrationum et displātiōnum in machīnīs cūtīculīs flūidī. Cum apice 11 mm et cāblō triaxiālī FEP-insectō 1,0 metrō (3,3 pedibus), 330706-005-046-10-02-00 3300 XL 11 mm Sonde Montata Retroversum offert latiorem linearem ambitum ad monitorandum positionem axialem (thrust), mensuras differentialis expansionis in turbinibus vaporis, positionem virgae in compressoribus reciprocantibus, functiones tachometri et sensus velocitatis zero, ac signa phasica Keyphasor. Probula habet corpus filetatum M10 × 1, resistentiam output 50 Ω, et sensibilitatem alimentationis infra 2 mV per voltum mutationis intrantis, idoneam ad automata machinarum gubernacula. Armatura flexibilis ex AISI 302 SST et cavis FluidLoc sunt optionales ad impediendum liquidorum ingressum; connexiones probulae ad cavia firmiter tenentur per connectores ClickLoc et per designa patentata CableLoc et TipLoc. 330706-005-046-10-02-00 3300 XL 11 mm Sonde Montata Retroversum compatibilis est cum systematis evolutionibus ab transductoribus seriei 7200 et integratur cum Systematibus Monitoris 3500 per novum software configurationis. Protectores connectorum et nutus clausurae cum foraminibus praeforatis ad filum tutelare augent fiduciam installationis in ambientibus automationis industrialis.
Usus
Mensurat Thrust Axialem in Axis: 330706-005-046-10-02-003300 XL 11 mm Probā Reverentī Montātā, cum eius apice 11 mm et cānālī longō 1,0 metrō (3,3 pedēs), praebet praecisam mensūram absque contactū displacementis axiālis usque ad 1,65 mm, id quod optime convenit ad observandum impulsum axiālem in cuneīs pelliculārum fluidārum.
Observāre Expansionem Turbinae Vapōris: Utiēns ampliatum intervallum lineāre 330706-005-046-10-02-003300 XL 11 mm Probae Reverentī Montātae, operātōrēs accurate capere possunt expansionem differentiālem rampae in turbinibus, ut motus axis rēctē reguletur.
Observāre Motum Virgae Compressoris Alternantīs: 330706-005-046-10-02-003300 XL 11 mm Probā Reverentī Montātā mensūrat descensum virgae et positionem virgae altā sensibilitāte (<2 mV pro voltō mutātō in intrōductiōne), ad sublevandam automāticam observationem compressoris.
Tachōmetrum et Detectiō Velōcitātis Nūllae: 330706-005-046-10-02-003300 XL 11 mm Probā Reverentī Montātā emittit praecisos signālēs velocitātis axis et velocitātis nūllae per suam rēsistentiam in ōutput 50 Ω, ita ut facile integrētur in systēmāta contrōlātōria.
Specifications
|
Temperatura Functionis et Servandi: |
-52°C ad +177°C (-62°F ad +351°F) |
|
Materia cavi extensionis: |
75 Ω triaxialis, fluoroethylenum propylene (FEP) isolatus |
|
Extensionis Cavi Armor (optionalis): |
Flexibilis AISI 302 SST cum FEP tuniculo exterius |
|
Coniunctio Campalis: |
0,2 ad 1,5 mm² (16 ad 24 AWG) [0,25 ad 0,75 mm² (18 ad 23 AWG) cum ferrulis] |
|
Resistentia Exitus: |
50 Ω |
|
Sensibilitas Subministrandi: |
Minus quam 2 mV mutatio in voltagine exitu per volt mutationem in voltagine introitu |
Aliquam commodo
Ampliatum Intervallum Lineāre cum Apice 11 mm: Apex 11 mm 330706-005-046-10-02-00probatio 3300 XL 11 mm inversa ad mensuram maioris displacementis (usque ad 1,65 mm) permittit, quae standardem probationem 8 mm pro automatis axis monitoribus excedit.
Magnus vis tractionis et adhaesio: Designa patentata TipLoc et CableLoc probationem 3300 XL 11 mm inversam ad probatiunculam capitis firme coniungunt vi tractionis 330 N, quae usum mechanicum in ambientibus altius vibrantis minuit. 330706-005-046-10-02-00probatio 3300 XL 11 mm inversa ad mensuram maioris displacementis (usque ad 1,65 mm) permittit, quae standardem probationem 8 mm pro automatis axis monitoribus excedit.
Praeservatio ab liquidis: Cavi FluidLoc et protectores connexorum optionales in probatione 3300 XL 11 mm inversa oleum aut alia liquida ne intrare sinunt, integritatem signi pro systematibus automationis servantes. 330706-005-046-10-02-00probatio 3300 XL 11 mm inversa ad mensuram maioris displacementis (usque ad 1,65 mm) permittit, quae standardem probationem 8 mm pro automatis axis monitoribus excedit.
Optiones flexibiles montandi: Cum filetis M10 × 1 et nutu retinente cum foraminibus praeforatis ad filum tutelare, probatio 3300 XL 11 mm inversa secure in angustis dispositionibus systematum automaticorum installari potest. 330706-005-046-10-02-00probatio 3300 XL 11 mm inversa ad mensuram maioris displacementis (usque ad 1,65 mm) permittit, quae standardem probationem 8 mm pro automatis axis monitoribus excedit.
Sine interruptione systematis evolutio: 330706-005-046-10-02-00probatio 3300 XL 11 mm inversa omnino probations series 7200 (11 mm et 14 mm) substituit, dum configurationes novissimae systematis monitorii 3500 sustinet, quod evolutiones automationis leniter permittit.