Conspectus
Locus originis: |
USA |
Nomen marcae: |
Bently Nevada |
Numerus exemplaris: |
135137-01 |
Particularia impaquetandi: |
Originales nova Officina Sigillata |
Tempus solutionis: |
5-7 dies |
Conditiones solutionis: |
T/T |
Vis Supplicandi: |
In stirpe |
Velox Detail
|
Requisita Spatii in Reticulo |
1 interstitium posterius plene altum |
|
Temperatura operativa |
−30°C ad +65°C (−22°F ad +150°F) |
|
Temperatura recondita |
-40°C ad +85°C (-40°F ad +185°F) |
|
Humiditas |
95% non condensans |
|
Signum |
Accipit ab uno ad quattuor signorum introitus |
|
Consumptio potentiae |
7,7 Vattus, ut solet, utendo Positione I/O |
|
Input impedimentum |
1 MΩ (introitus DC LVDT) 10 kΩ (introitus Proximitor vel RPT) 137 kΩ (introitus AC LVDT) 200 kΩ (introitus Potentiometri Rotatorii) |
|
Sensibilitas ad Impulsum |
3.94 mV/μm (100 mV/mil) aut 7.87 mV/μm (200 mV/mil) |
|
Dimensiones: |
2,5 × 11,2 × 24,2 cm |
|
Pondus: |
0.4Kg |
Descriptio
Illud 135137-01Modulus Positionis I/O est monitor quattuor canalium ad automationem industrialem et machinarum gubernationem destinatus. 135137-01accipit 1–4 signa intrantis ab transductoribus proximitatis, LVDT directa vel alternata, potentiometris rotativis, aut RPT, cum impedimento intrantis a 1 MΩ pro LVDT directis usque ad 200 kΩ pro potentiometris rotativis. Sensibilitas ad vim propulsivam est 3,94 aut 7,87 mV/μm, dum sensibilitas ad expansionem differentialem a 0,394 usque ad 7,874 V/mm variat secundum electionem pleni scalae.
Illud 135137-01operatur in scissura posteriori altitudinis integrae inter −30 °C et +65 °C, et servatur inter −40 °C et +85 °C, umiditatem non condensantem usque ad 95 % admittens. Consumptio energiae est 7,7 W (valore typico). Puncta programmabilia allarum pro vi propulsiva, expansione differentiali, et positione valvulae per Software Configurationis Rack 3500 statuuntur, cum praecisione intra 0,13 % valoris desiderati. Responsiones frequentialis pro filtris directis et interstitiis sunt −3 dB ad 1,2 Hz et 0,41 Hz, respective.
In systematis automationis, 135137-01praebet praesentem observationem positionis axialis, positionis valvulae, et expansionis differentialis, dataque ad usum protectionis et regulae turbinum, compressorum, et machinarum processualium offerens.
Usus
Observa positionem axialem (thrust) in machinis rotantibus
Illud 135137-01admittit 1–4 intrinsecos transductores proximitatis aut signales DC LVDT, cum sensibilitate thrust 3,94 vel 7,87 mV/μm. Ingeniarii utuntur 135137-01ad sequendam motum axialem in turbinibus et compressoribus, cum directa responsione filtrorum frequentiali −3 dB ad 1,2 Hz pro exacta mensura.
Mensura expansionem differentialem per axes aut carcasas
Illud 135137-01mensurat expansionem differentialem cum sensibilitate ab 0,394 ad 7,874 V/mm secundum plenum ambitum scalae. Responsio frequentialis filtrorum interstitii ad −3 dB 0,41 Hz operatores permittit lente progredientes expansionis tendentias observare et interference mechanicae praecavere.
Sequere positionem valvulae in systematibus automaticis regulae
Utens signales AC LVDT aut potentiometra rotatoria, 135137-01monitorat motum valvulae cum praecisione ±0,33 % in scala plena. Modulus datam ad systema automationis emittit ad regulandam valvulam, generandam alarmas et annotandum operationes.
Subsidium praebet monitoriae incrementi graduali et incrementi differentialis complementaris.
Illud 135137-01potest configurare functiones standard vel non-standard incrementi differentialis unius aut duorum graduum, permittens observationem in tempore reali incrementi carceris aut axis ad protectionem machinarum et optimisationem processuum.
Specificationes
|
Sensibilitas Incrementi Differentialis |
0,394 mV/μm (10 mV/mil) aut 0,787 mV/μm (20 mV/mil) |
|
Sensibilitas Incrementi Differentialis Gradualis |
0,394 V/mm (10 mV/mil), 0,787 V/mm (20 mV/mil), 3,937 V/mm (100 mV/mil), aut 7,874 V/mm (200 mV/mil) |
|
Impulsus et Incrementum Differentiale (Accuratio ) |
Intra ±0,33% valoris pleni, typice ±1% maximum |
|
Impulsus et Incrementum Differentiale (Responsio in Frequentia Filtrationis Directae ) |
−3 dB ad 1,2 Hz |
|
Impulsus et Incrementum Differentiale (Responsio frequentialis filtrī interstitiālis ) |
−3 dB ad 0,41 Hz |
|
Puncta constitūta allārmis |
Utere ōrnāmentō 3500 Rack Configuration Software ad constituenda puncta monitūs et perīculī pro valoribus directē mēnsūrātīs ā monitorē. Allārmae sunt adiūstābiles ab 0 usque ad 100 % plēnī scālae pro quōlibet valōre mēnsūrātō. Tamen, cum scāla plēna excedit ambitum trānsductōris, ambitus trānsductōris limitābit punctum constitūtum. |
|
Accuratio punctorum allarum |
Intra 0,13% valoris desiderati |
|
|
|
|
Accūrātia positīōnis vālvulae |
Intra ±0,33% valoris pleni, typice ±1% maximum |
|
Positīō vālvulae (responsiō frequentialis filtrī directī) |
−3 dB ad 1,2 Hz |
|
Positīō vālvulae (responsiō frequentialis filtrī interstitiālis) |
−3 dB ad 0,41 Hz |
Aliquam commodo
Lata subsidia signorum introductorum pro pluribus transductoribus
Illud 135137-01accipit transductores propinquitatis, LVDTs directae et alternantis currentis, RPTs, et potentiometra rotatoria. Impedantia introducta variat ab 1 MΩ ad 200 kΩ, quae integrationem cum variis sensoribus positionis industrialibus permittit.
Exacta puncta allarum et mensura
Illud 135137-01praebet exactitudinem punctorum allarum intra 0.13% scalae plenae, et exactitudinem mensurae pro impetu, expansione differentiale, et positione valvulae intra ±0.33% (typice), ±1% (maxime). Haec fidam activationem actionum automationis et tutelae confirmat.
Integratio in scissuram altam cum consumptu electrico parvo
Illud 135137-01installatur in scissura posteriori alta et trahit solum 7.7 W (typice), quod permittit multa modula in armario 3500 sine superatione limitum potentiae aut spatii.
Programmabilis per Software Configurationis Armarii 3500
Ingeniores constituere possunt intervalla scalae plenae et configurare variabiles mensuratas, ut positionem axialem, expansionem differentialem, et positionem valvulae, absque calibratura in loco. The 135137-01minuit tempus installationis et configurationis in systematibus automationis.
Responsio frequentialis ad usum supervisionis mechanicae aptata
Responsiones frequentiales directae et filtrorum interstitialium −3 dB ad 1,2 Hz et 0,41 Hz respective permittunt 135137-01capere tam motus axiales celeres quam expansionem differentialem lentam, praebentes data utenda ad controllem machinarum in tempore reali.