  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS · SIMATIC ET 200SP HA

6DL1134-6TH00-0PH1 SIMATIC ET 200SP HA AI 16xI HART Module

The SIMATIC ET 200SP HA AI 16xI 2-wire HART module provides sixteen current-input channels, 16-bit conversion, channel diagnostics and run-time reparameterization.

At a Glance

Brand Siemens
Model 6DL1134-6TH00-0PH1
Product Type sixteen-channel HART analog input module
Core Function Acquires sixteen 2-wire current signals and exchanges HART data
Application or Compatible Series ET 200SP HA process I/O stations using current transmitters with HART

Exact Identification

Match 6DL1134-6TH00-0PH1 character by character and confirm the complete SIMATIC ET 200SP HA AI 16xI HART Module designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The SIMATIC ET 200SP HA AI 16xI 2-wire HART module provides sixteen current-input channels, 16-bit conversion, channel diagnostics and run-time reparameterization.

Sixteen two-wire current inputs reduce module count in process I/O stations. HART communication supports compatible intelligent field transmitters. The module is supported by current PCS 7, PCS neo, STEP 7 and GSDML engineering environments.

Ordering focus: confirm terminal-block variant, all sixteen measuring ranges, HART devices, redundancy setting, engineering version and channel diagnostics.
Key Functions

High Channel Density

Sixteen two-wire current inputs reduce module count in process I/O stations.

Integrated HART

HART communication supports compatible intelligent field transmitters.

HA Engineering Support

The module is supported by current PCS 7, PCS neo, STEP 7 and GSDML engineering environments.

Official Specifications
Firmware Version V1.1
Firmware Update Supported
Identification Data I&M0 to I&M3
TIA Portal Baseline V16
STEP 7 Baseline V5.6
PCS 7 Baseline V9
PCS neo Baseline V3
GSDML Baseline V2.3
Module Redundancy Supported with M1 terminal arrangement
Reparameterization in RUN Supported
Rated Supply 24 V DC
Permissible Supply Range 19.2 to 28.8 V DC
Reverse-Polarity Protection Supported
Current Consumption Without Sensors 80 mA
Power Loss 4.5 W
Analog Input Channels 16
Transmitter Connection 2-wire current
HART Communication Supported
Resolution 16 bit
Basic Accuracy ±0.1%
Frequently Asked Questions

How many current-input channels are provided by 6DL1134-6TH00-0PH1?

Sixteen analog input channels are available.

Can 6DL1134-6TH00-0PH1 communicate with HART transmitters?

Yes; HART communication is supported on the current inputs.

Can parameters be changed while 6DL1134-6TH00-0PH1 is running?

Yes; reparameterization during RUN is supported.

Which signal wiring is intended for 6DL1134-6TH00-0PH1?

The module is designed for two-wire current transmitters.

What conversion resolution does 6DL1134-6TH00-0PH1 provide?

The analog values are converted with 16-bit resolution.

Can 6DL1134-6TH00-0PH1 be used in a redundant I/O arrangement?

Yes; module redundancy is supported with the specified M1 terminal arrangement.

What must be saved before replacing 6DL1134-6TH00-0PH1?

Preserve channel parameters, measuring ranges, HART assignments, redundancy settings and the process-control project.

Compatibility & Ordering Notes
Before ordering 6DL1134-6TH00-0PH1: confirm terminal-block variant, all sixteen measuring ranges, HART devices, redundancy setting, engineering version and channel diagnostics.

Compatibility Checklist

  • Match the installed H1, M1, N0, H0 or M0 terminal-block arrangement exactly.
  • Back up every channel range, HART address and diagnostic parameter.
  • Verify redundancy pairing and the approved PCS 7 or PCS neo hardware configuration.
Hot Selling Models
Murr Elektronik 51300
Weidmüller 0198020000
3RP1505-1RW30
GV2ME20 GVAE11
XB4BW35B5
7000-08101-2311000
Allen-Bradley 1771-IBD/B
5SY6106-7
CG6.A023.FS2.F793 A000167655/100
5SY4104-7
DILM7-10 DILA-XHI31 DILM12-XSPR240
DILM7-01 DIL A-XHI31 + DIL M12-XSPR240
TUVA278/13
GV2-P03 GV2-AN11
DIL0AM

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.