Overview
Place of Origin: |
USA |
Brand Name: |
Bently Nevada |
Model Number: |
170180-01-00 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Quick Detail
|
Parameter |
Specification |
|
Product Type |
FieldMonitor External Transducer I/O Module |
|
Number of Channels |
2 |
|
Channel A |
-24 VDC Proximitor or Accelerometer |
|
Channel B |
-24 VDC Proximitor or Accelerometer |
|
Operating Temperature |
-34°C to +85°C (-30°F to +185°F) |
|
Storage Temperature |
-40°C to +105°C |
|
Weight |
277 g (0.61 lb) |
|
Frequency Response |
-5% at >25 kHz |
|
Current Draw |
2.0 mA maximum (without transducer) |
|
Current Limit Setpoint |
33.6 mA minimum, 37.6 mA maximum at 25°C (77°F) |
|
Application |
Industrial machinery health monitoring |
|
Dimension: |
12.7x2.1x10.5cm |
|
Weight: |
0.28kg |
Description
The 170180-01-00 FieldMonitor External Transducer I/O Module is a dual-channel interface designed for industrial machinery health monitoring. Channel A and Channel B support -24 VDC Proximitor or accelerometer inputs. The 170180-01-00 FieldMonitor External Transducer I/O Module operates from -34°C to +85°C (-30°F to +185°F) with storage temperatures from -40°C to +105°C, handling up to 95% non-condensing humidity. It weighs 277 g (0.61 lb) and provides a frequency response of -5% at >25 kHz. Current draw is 2.0 mA maximum without a transducer, with a current limit setpoint between 33.6 mA and 37.6 mA at 25°C (77°F). The 170180-01-00 FieldMonitor External Transducer I/O Module outputs 0 to 10 VDC signals and operates from a 24 VDC ±20% supply. It withstands vibration up to 10 g peak (10–2000 Hz) and shock up to 50 g peak (1/2 sine, 11 ms). Designed for automated monitoring systems, the 170180-01-00 FieldMonitor External Transducer I/O Module ensures accurate eddy proximity check inputs and precise signal conversion for predictive maintenance in turbines, compressors, and rotating machinery.
Applications
Connect Proximitor or Accelerometer Sensors to Monitoring Systems
The 170180-01-00 FieldMonitor External Transducer I/O Module allows direct signal input from -24 VDC Proximitor or accelerometer sensors into 3500 monitoring racks or industrial data acquisition systems.
Transmit Accurate Vibration Signals for Machinery Analysis
With 0–10 VDC output and -5% frequency response at >25 kHz, the 170180-01-00 FieldMonitor External Transducer I/O Module ensures reliable high-speed vibration data for predictive maintenance.
Deploy Near Harsh Machinery Environments
The 170180-01-00 FieldMonitor External Transducer I/O Module withstands -34°C to +85°C, 10 g vibration, and 50 g shock, allowing installation close to turbines, compressors, and rotating equipment.
Specifications
|
Humidity |
0 to 95% non-condensing |
|
Vibration Resistance |
10 g peak (10 to 2000 Hz) |
|
Shock Resistance |
50 g peak (1/2 sine, 18 g, 11 ms) |
|
Input Type |
Eddy proximity check |
|
Output Signal |
0 to 10 VDC |
|
Supply Voltage |
24 VDC ±20% |
Competitive Advantage
Maintain High Signal Accuracy Under Load
The 170180-01-00 FieldMonitor External Transducer I/O Module processes eddy proximity and accelerometer signals with 0–10 VDC outputs and precise current limits (33.6–37.6 mA), minimizing measurement errors.
Operate in Extreme Temperature and Humidity
Rated for -34°C to +85°C operation and 95% non-condensing humidity, the 170180-01-00 FieldMonitor External Transducer I/O Module functions reliably in industrial automation environments.
Withstand Vibration and Shock in Machinery Rooms
Vibration tolerance of 10 g peak (10–2000 Hz) and shock resistance of 50 g peak (1/2 sine, 11 ms) allow the 170180-01-00 FieldMonitor External Transducer I/O Module to be installed near heavy rotating equipment.
Support Rapid Sensor Integration
Standard input channels for -24 VDC Proximitor or accelerometer sensors enable the 170180-01-00 FieldMonitor External Transducer I/O Module to be quickly connected, reducing installation time and minimizing system downtime.
Enable Precise Predictive Maintenance
The 170180-01-00 FieldMonitor External Transducer I/O Module outputs high-fidelity 0–10 VDC signals suitable for automated monitoring systems, allowing accurate machinery health assessment and maintenance planning.