Siemens SIMADYN D 6DD1688-0AD0 SS4 Serial Communication Module
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Install only on a compatible SIMADYN D CS7 support module.
- Keep the total number of communication plug-ins at or below three per CS7.
- Match the configured DUST1, DUST2, DUST3 or USS protocol to the field device.
- Use the correct standard or optional physical-interface module and cable pinout.
- Keep the configured transmission rate within the protocol and interface limits.
- Restore the CS7 plug-in position and HW Config assignment exactly.
- Pro servitium USS, confirma quod SS4 manet magister bus et serva omnes adresses servorum.
SIEMENS · SIMADYN D
6DD1688-0AD0 SS4 Serial Communication Module
Siemens 6DD1688-0AD0 is the SIMADYN D SS4 serial communication plug-in module for the CS7 support module. Its standard physical interface is RS-232 for connection to a PC COM port, while optional interface modules support TTY, V.24 printer signaling or RS-485 USS communication. The supported DUST1, DUST2, DUST3 and USS protocols cover engineering PCs, message printers, SIMATIC S5 systems, operator panels, text displays and drive converters. The CS7 can carry up to three communication modules and exchanges data with CPU modules through its 16 KB dual-port RAM.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6DD1688-0AD0 |
| Typus Producti | SIMADYN D Serial Communication Plug-In Module |
| Functio principalis | Adds a configurable serial communication channel to a CS7 support module |
| Applicatio vel series compatibiles | SIMADYN D CS7 communication assemblies |
CS7 Assembly Match
Confirm the CS7 support module, selected plug-in position and remaining capacity before installation.
Selectio Protocolli
Match DUST1, DUST2, DUST3 or USS to the connected engineering device, printer, SIMATIC S5 system or drive equipment.
Interfacing Physica
Use the standard RS-232 channel or select the exact SS1, SS2 or SS31 option required by the field wiring.
Product Overview
Siemens 6DD1688-0AD0 is the SIMADYN D SS4 serial communication plug-in module for the CS7 support module. Its standard physical interface is RS-232 for connection to a PC COM port, while optional interface modules support TTY, V.24 printer signaling or RS-485 USS communication. The supported DUST1, DUST2, DUST3 and USS protocols cover engineering PCs, message printers, SIMATIC S5 systems, operator panels, text displays and drive converters. The CS7 can carry up to three communication modules and exchanges data with CPU modules through its 16 KB dual-port RAM.
The same plug-in supports engineering, printing, SIMATIC S5 and USS applications through the assigned protocol software. Optional interface modules extend the standard RS-232 port to 20 mA TTY, V.24 printer control or RS-485. CPU communication runs through the 16 KB dual-port RAM provided on the CS7 support module.
Key Functions
Configurable Serial Communication
Eadem plug-in adhibetur ad ingenieriam, ad impressionem, ad applicationes SIMATIC S5 et ad USS per software protocolli assignatum.
Interfaccia elettrica selezionabile
Moduli interfacis optionales extensionem praebent portui standard RS-232 ad 20 mA TTY, ad V.24 impressionis regulam aut ad RS-485.
CS7 Processoris Data-Exchange
Communicatio CPU per 16 KB RAM duplex-portum in modulo supportis CS7 praebetur.
Official Specifications
| Designatio Moduli | SS4 modulum communicationis |
|---|---|
| Modulus Host | Modulus subsidii CS7 |
| Maximi moduli per CS7 | 3 moduli communicationis |
| CPU Data-Exchange Memoria | 16 KB RAM duplex-portum in modulo supportis CS7 |
| Interfacis Physicae Standard | RS-232 pro interfacium COM computatrum personale |
| Interfacium SS1 optionale | linea currentis 20 mA TTY pro vinculis longis et detectione interruptus fideli |
| Interfacium SS2 optionale | RS-232 V.24 pro impressoribus utentibus signis controlis RTS et CTS |
| Interfacium SS31 optionale | RS-485 pro protocollo USS |
| Maximum Baud Rate | 187.5 kbaud |
| Applicatio DUST1 | Computatra personalia ingeniorum et operatorum pro onerando programma et inchoatione |
| Applicatio DUST2 | Conectio inter impressorem nuntiorum et machinam |
| Applicatio DUST3 | Conectio SIMATIC S5 per AS 512 aut CP 525 |
| Rolus operativus USS | Magister USS in bus USS |
| Typi dispositivorum USS | Panella operatoria OP2, displayes textuales VD1 et conversores impulsum |
| Methodus engineering | CS7, modulus et positio inserti configurata in Configuratio HW |
Quaestiones Frequenter Rogatae
Quis modulus hospitis requiritur pro 6DD1688-0AD0?
Installa il plug-in su un modulo di supporto CS7 compatibile e configura la sua posizione selezionata nella configurazione hardware.
Quanti moduli 6DD1688-0AD0 può trasportare un CS7?
Un modulo di supporto CS7 accetta fino a tre moduli di comunicazione.
Quale interfaccia seriale è standard sul 6DD1688-0AD0?
L'interfaccia configurabile standard utilizza RS-232 per la connessione a una porta COM del PC.
Quale opzione fornisce la comunicazione RS-485 USS per il 6DD1688-0AD0?
Utilizza il modulo di interfaccia SS31 per il livello fisico RS-485.
Il 6DD1688-0AD0 può comunicare con un sistema SIMATIC S5?
Utilizza il protocollo DUST3 per una connessione tramite AS 512 o CP 525.
Qual è la velocità in baud massima del 6DD1688-0AD0?
The documented upper transmission rate is 187.5 kbaud and also depends on the protocol and interface option.
What should I save before replacing 6DD1688-0AD0?
Record the CS7 slot, configured protocol, baud rate, interface option, cable pinout and connected device before removal.