- Usus varians PTI et congruens motor servus et configuratio controlleris.
- Praebere specificatam supplitationem AC triphasicam et connectere signa digitalia et analogica secundum schemata connexorum machinae.
- Aerem ventilatoris libere fluere permittere et in intervallo ambienti 0–45 °C operari.
- Comparare currentem nominalem 5.3 A et dimensiones FSB dum substitutum seligitur.
6SL3210-5FE11-5UA0 SINAMICS V90 PTI Servo Drive
Triphasic 380–480 V V90 PTI drive cum current output nominalis 5.3 A, structura FSB et communicatio serialis.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6SL3210-5FE11-5UA0 |
| Typus Producti | Servo coegi |
| Functio principalis | Controllo motoris servo in systemate imperativum impulsum |
| Applicatio | Positioning of machine axis and replacement of servo drive |
Integration of PTI servo drive
The PTI variant supports integration into a machine axis system using the appropriate motor and controller command arrangement.
Machine signal connections
Ten digital inputs, six digital outputs, and two analog inputs and outputs each support the machine control wiring.
Serial communication and cooling
USS and Modbus RTU provide serial communication while fan cooling supports operation within the specified ambient range.
Product Overview
6SL3210-5FE11-5UA0 Provides a 400 V-class SINAMICS V90 PTI servo drive for machine axis control.
The FSB drive combines digital and analog signal connections with USS and Modbus RTU communication, using a fan-cooled cabinet installation.
Key Functions
Integration of PTI servo drive
The PTI variant supports integration into a machine axis system using the appropriate motor and controller command arrangement.
Machine signal connections
Ten digital inputs, six digital outputs, and two analog inputs and outputs each support the machine control wiring.
Serial communication and cooling
USS and Modbus RTU provide serial communication while fan cooling supports operation within the specified ambient range.
Official Specifications
| Classis potentiae ductus | 1.5 kW |
|---|---|
| Alimentatio Lineae | Alternans triphasicus, 380–480 V, +10%/-15% |
| Input frequency | 45–66 Hz |
| Currentis Output Aestimatus | 5.30 A |
| Currentia maxima emissa | 15.90 A |
| Ingressus Digitales | 10 |
| Emissiones Digitales | 6 |
| Ingressus et egressus analogici | 2 inputs et 2 outputs |
| Communication Protocols | USS et Modbus RTU |
| Protectio Inclusis | IP20 / UL apertum typus |
| Structura Mechanica | FSB |
| Modus refrigerationis | Fan |
| Altitudo Installationis | 1 000 m |
| Operans ambientium temperatus | 0–45 °C |
| Temperatura servandae | −40 ad +70 °C |
| Maximum Operating Humidity | 90% |
| Dimensiones (L × H × D) | 100 × 180 × 220 mm |
| Ponderis netum | 2,45 Kg |
Quaestiones Frequenter Rogatae
Num 6SL3210-5FE11-5UA0 ex uniphaseo 230 V fonte uti potest?
Ingressus specificatus est triphasicus 380 ad 480 V AC.
Num 6SL3210-5FE11-5UA0 15.9 A continuo praebere potest?
The rated output current is 5.3 A while 15.9 A is the maximum output current rather than the continuous rating.
Which serial protocols can my controller use with 6SL3210-5FE11-5UA0?
Hoc impulsum USS et Modbus RTU communicationem supportat.
Can 6SL3210-5FE11-5UA0 provide eight digital outputs to a machine controller?
The drive has six digital outputs, so an eight-output requirement needs additional output resources.
Which analog connections should I include in the cable plan for 6SL3210-5FE11-5UA0?
The drive provides two analog inputs and two analog outputs.
Does 6SL3210-5FE11-5UA0 need forced cooling in its operating arrangement?
The drive uses fan cooling and is specified for an operating ambient of 0 to 45 °C.
How much space should I reserve for the body of 6SL3210-5FE11-5UA0?
The FSB body is 100 mm wide, 180 mm high and 220 mm deep before adding the required wiring and ventilation clearance.