Siemens 6SE7090-0XX85-1NA0 SIMOVERT MASTERDRIVES PTP1 RS485 Interface Board
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Utatur electronicis controlis CUR cum versione hardware 06 vel posteriori et versione software 3.0 vel posteriori.
- Adaptet tabulam ad positionem A2 destinatam et connectat utrosque conectores X115 et X116 recte.
- Eligat pachetum tabulae unius aut pachetum 12-pulsuum tabularum duarum, ut numerum unitatum congruat.
- Configurat selectionem datorum processus, velocitatem baud, numerum verborum datorum rete, tempus defectus telegrammatis et protocollum pro nexu.
6SE7090-0XX85-1NA0 SIMOVERT MASTERDRIVES PTP1 RS485 Interface Board
A PTP1 submodule supplied with two spacers for adding the SST2 serial interface to a compatible CUR electronics board.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6SE7090-0XX85-1NA0 |
| Typus Producti | Plug-in serial interface board |
| Functio principalis | Enabling SST2 peer-to-peer communication |
| Applicatio | CUR-controlled rectifier and regenerating units |
SST2 serial expansion
The plug-in board makes the basic unit SST2 interface available.
Peer-to-peer data exchange
Parameter P688 selects peer-to-peer operation, with separate settings for data selection, baud rate, and telegram failure time.
Integrated line termination
Receive termination and bias resistors are fitted on the interface board.
Product Overview
6SE7090-0XX85-1NA0 adds the SST2 interface to the compatible CUR control electronics.
The plug-in PTP1 board occupies the A2 submodule position and connects through X115 and X116, with separate receive and transmit terminals at X117 for the peer-to-peer link.
Key Functions
SST2 serial expansion
The plug-in board makes the basic unit SST2 interface available.
Peer-to-peer data exchange
Parameter P688 selects peer-to-peer operation, with separate settings for data selection, baud rate, and telegram failure time.
Integrated line termination
Receive termination and bias resistors are fitted on the interface board.
Official Specifications
| Field interface | RS485, separate receive and transmit pairs |
|---|---|
| X117 receive terminals | Terminal 1: R+; terminal 2: R− |
| X117 transmit terminals | Terminalis 3: T+; terminalis 4: T− |
| Terminalis signali ad terram | Terminalis X117 5 |
| Resistentia terminatio receptus | 150 Ω inter X117-1 et X117-2 |
| Resistentiae bias receptus | 390 Ω ab X117-1 ad +5 V; 390 Ω ab X117-2 ad terram |
| Conectora tabulae ad CUR | Strips conectorum feminarum X115 et X116 |
| Continens Plicae | Una tabula PTP1 et duo spaciatores |
Quaestiones Frequenter Rogatae
Quae versiōnēs hardware et software CUR sunt necessariae pro 6SE7090-0XX85-1NA0?
Electronica contrōlis debet habēre versiōnem hardware 06 aut superiōrem et versiōnem software 3.0 aut superiōrem.
Quōmodo communicatiō inter pares eligitur post installātiōnem 6SE7090-0XX85-1NA0?
Pōne P688 ad 1 ut prōtocolum inter pares in SST2 eligātur.
Ubi 6SE7090-0XX85-1NA0 in electronica CUR inseritur?
Mōnta submodulum super spaciīs praesūmptīs cum X115 et X116 insertīs in pinīs CUR correspondēntibus.
Quae terminālia receptiōnis utenda sunt pro nexū RS485 in 6SE7090-0XX85-1NA0?
Cōnecte conductōrēs receptiōnis positīvōs et negatīvōs ad X117-1 et X117-2 respectīvē.
Num 6SE7090-0XX85-1NA0 iam resistēntiās terminātiōnis inter pares continet?
Tabula continet terminationem receptionis 150 Ω et duas resistentias bias 390 Ω.
Estne unum pachetum 6SE7090-0XX85-1NA0 completum kit interfaciale duarum unitatum pro operatione 12-pulsuum?
Pachetum tabulae unius continet unam interfaciem, dum pachetum standard 12-pulsuum continet duas tabulas cum spaciatoribus pro duabus unitatibus.
Quae regula tempus defectus telegrammatis pro 6SE7090-0XX85-1NA0 regit?
Parametrum P687.i003 tempus defectus telegrammatis pro interfacie SST2 definit.