Siemens SIMOVERT MASTERDRIVES CUR Control Module 6SE7090-0XX85-1DA0
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Product Overview
- Key Functions
- Official Specifications
- Quaestiones Frequenter Rogatae
- Compatibility & Ordering Notes
- Hot Selling Models
- Producta commendata
Conspectus
SIEMENS · SIMOVERT MASTERDRIVES
6SE7090-0XX85-1DA0 SIMOVERT MASTERDRIVES CUR Control Module
Hoc est peculiare partem de Siemens SIMOVERT MASTERDRIVES: CUR Control Module pro unitatibus infeed et infeed/regenerative feedback specificatis; pachetum software T434E adhibendum separatim pro configuratione servitii.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6SE7090-0XX85-1DA0 |
| Typus Producti | Modulus controlis substitutivus |
| Functio principalis | Fungitur functione CUR controlis pro unitatibus infeed et infeed/regenerative feedback congruentibus |
| Applicatio vel series compatibiles | Applicationes servitii et reparationis SIMOVERT MASTERDRIVES utentes congregationem infeed congruentem |
Identificatio exacta.
Compare 6SE7090-0XX85-1DA0 charactere per characterem et confirma integram designationem SIMOVERT MASTERDRIVES CUR Control Module.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
Hoc est peculiare partem de Siemens SIMOVERT MASTERDRIVES: CUR Control Module pro unitatibus infeed et infeed/regenerative feedback specificatis; pachetum software T434E adhibendum separatim pro configuratione servitii.
Restaurat functiōnem contrōlis designātam in unitāte infeed coincidentī vel in unitāte infeed/regenerātīvā ad retribūtiōnem. Electiō fit secundum numerum artīculī completum et configurātiōnem unitātis potentiālis MASTERDRIVES installātam.
Key Functions
Functiō Contrōlis CUR
Restaurat functiōnem contrōlis designātam in unitāte infeed coincidentī vel in unitāte infeed/regenerātīvā ad retribūtiōnem.
Substitūtiō Specifīca pro Modellō
Electiō fit secundum numerum artīculī completum et configurātiōnem unitātis potentiālis MASTERDRIVES installātam.
Subsidium Software Definitum
Pacāgus subsidii software associātus T434E habet numerum artīculī Siemens separatim.
Official Specifications
| Subsidium Software Associātum | 6SW1701-0DA14 |
|---|---|
| Software suggestum | T434E |
| Ponderis netum | 0.400 kg |
| Dimensiones Confectionis | 26 x 33 x 9,5 cm |
| Unitas Quantitatis | 1 piece |
| Quantitas ambulationis | 1 |
| UPC | 662643431742 |
| Codex Commoditatum | 85049090 |
| Numerus Catalogi | DA65E/LD |
| Gruppus Productorum | 4933 |
| Codex Gruppi | R2S7 |
| Classificatio ad Exportationem | ECCN: N / AL: N |
| Compliantia ad Restrictionem Substantiarum RoHS | Datum |
Quaestiones Frequenter Rogatae
Quae compositio impulsum destinatur ad 6SE7090-0XX85-1DA0?
Utere illud solum in SIMOVERT infeed adaequato aut in unitate infeed/regenerative feedback adaequata, quae identificatur per configurationem installatam.
Quae subsidia software sunt associata cum 6SE7090-0XX85-1DA0?
Pacchetum subsidii T434E specificatum ordinatur sub numero articuli 6SW1701-0DA14.
Potestne 6SE7090-0XX85-1DA0 seligi sola specie?
Non; compara numerum totum articuli, versionem unitatis de controllo, typum unitatis de potentia et dispositionem connectorum antequam installatur.
Quod gradus de securitate electrica est necessarium antequam 6SE7090-0XX85-1DA0 substituitur?
Isolanda est conversio, exspectandum est ut nexus DC evacuetur, et absentia voltatis probanda est secundum proceduram plantae approbatam.
Quomodo 6SE7090-0XX85-1DA0 tractanda est dum installatur?
Utere controllis electrostaticis terratis et evita tangere componentes electronicos vel contactus connectorum.
Quae informationes de configuratione servandae sunt antequam 6SE7090-0XX85-1DA0 substituitur?
Conservare il set di parametri di guida, la versione del software, il registro di messa in servizio, i riferimenti di cablaggio e la cronologia dei guasti.
Che cosa deve essere verificato dopo l'installazione del 6SE7090-0XX85-1DA0?
Verificare i connettori, le alimentazioni ausiliarie, l'assegnazione del software, la diagnostica e il test funzionale autorizzato dell'alimentazione prima di rimettere in servizio l'inverter.
Compatibility & Ordering Notes
Index Compatibilitatis
- Utilizzare esclusivamente nell'assemblaggio specifico di SIMOVERT MASTERDRIVES previsto per questo modulo di controllo CUR.
- Ordinare o conservare il supporto software T434E corrispondente e conservare il set di parametri di guida verificato.
- Seguire la procedura di blocco del convertitore, di scarica del collegamento in corrente continua (DC-link) e di protezione contro le scariche elettrostatiche (ESD) prima di aprire l'unità.