Conspectus
- Adaptare ad hostem, formatum cartae et capacitatem requisitam supportatam.
- Servare copias de projecto ante expurgationem aut formattationem cartae usae.
- Utere procedura SIMATIC pro formattatione et expurga quodlibet opus fortis activum antequam agas gradus servitii specificatos.
- Planifica onerem scripturale una cum exigentia retentionis dependentis a cyclo.
6ES7954-8LE03-0AA0 SIMATIC 12 MB Flash Memory Card
3.3 V SIMATIC Flash-EPROM card with 12 MB capacity, at least 500000 write/delete operations and cycle-dependent data retention.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7954-8LE03-0AA0 |
| Typus Producti | CPU and drive memory card |
| Functio principalis | Storage of host program and configuration data |
| Applicatio | Compatible S7-1x00 CPU et fentes SINAMICS |
Médium flash de douze mégaoctets
La carte fournit douze mégaoctets de stockage non volatile en Flash-EPROM.
Endurance en écriture définie
Au moins 500 000 opérations d’écriture/suppression sont spécifiées pour le médium.
Gestion hôte SIMATIC
Les procédures du CPU et des outils d’ingénierie conservent le format de la carte et définissent la réaction au remplacement de la carte.
Product Overview
6ES7954-8LE03-0AA0 fournit douze mégaoctets de stockage Flash-EPROM pour les CPU S7-1x00 et les équipements SINAMICS compatibles.
La carte compacte associe une interface 3,3 V à une endurance en écriture spécifiée et à des conditions de rétention des données, tandis que le formatage SIMATIC et les procédures de service hôte préservent son utilisation dans le contrôleur.
Key Functions
Médium flash de douze mégaoctets
La carte fournit douze mégaoctets de stockage non volatile en Flash-EPROM.
Endurance en écriture définie
Au moins 500 000 opérations d’écriture/suppression sont spécifiées pour le médium.
Gestion hôte SIMATIC
Les procédures du CPU et des outils d’ingénierie conservent le format de la carte et définissent la réaction au remplacement de la carte.
Official Specifications
| Facultatem repono | 12 MB |
|---|---|
| Memoria Technologia | Flash-EPROM |
| Tensio interfaciei operativae | 3.3 V |
| Minimum Write/Delete Endurance | 500000 operationes |
| Retentio datorum infra 50000 operationes scribendi/deleendi | Minime 10 annos post programmationem finalem |
| Retentio datorum supra 450000 operationes scribendi/deleendi | Saltem 1 annus post ultimam programmationem |
| Dimensiones | 24 × 32 × 2.1 mm (latus × altitudo × profunditas) |
| Pondus Approximatum | 3 g |
Quaestiones Frequenter Rogatae
Possumne reformare 6ES7954-8LE03-0AA0 per instrumentum formattandi Windows?
Serva formatum SIMATIC et utere procedura formattandi CPU vel STEP 7 probata, non autem formattando per Windows.
Utrum oneratio novi projecti in 6ES7954-8LE03-0AA0 automatum removet officium fortis activum?
Officium fortis activum retinetur et debet deleri antequam cardo e CPU removetur aut superimprimatur in PC.
Quod gradus CPU post removalem vel insertionem 6ES7954-8LE03-0AA0 requiritur?
Perficere reset memoriam CPU post removalem aut insertionem cartae, ut CPU ad statum functionalem restituatur.
Num formatum projecti currentis in 6ES7954-8LE03-0AA0 ab antiquiore versione producti engineering sine mutatione uti potest?
Formatum cartae non est retro-compatibile, et eius data delenda sunt antequam cum antiquiore versione producti utatur.
Quot operationes scribendi/deleendi pro figura durabilitatis 6ES7954-8LE03-0AA0 utendae sunt?
Specifica minima durabilitas est 500000 operationes scribendi/deleendi.
Num decem annos retentio post plus quam 450000 scripturas in 6ES7954-8LE03-0AA0 supponere possum?
Post plus quam 450000 operationes scribendi/deleendi, specifica minima retentio post ultimam programmationem est unus annus.
Quando conditio minima decem annorum retentiae ad 6ES7954-8LE03-0AA0 applicatur?
Minima decem annorum retentio post ultimam programmationem applicatur, si numerus operationum scribendi/deleendi infra 50000 est.