Siemens SIMATIC S7-1500F CPU 1513F-1 PN 6ES7513-1FL01-0AB0
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Product Overview
- Key Functions
- Official Specifications
- Quaestiones Frequenter Rogatae
- Compatibility & Ordering Notes
- Hot Selling Models
- Producta commendata
Conspectus
SIEMENS · SIMATIC S7-1500F
6ES7513-1FL01-0AB0 SIMATIC S7-1500F CPU 1513F-1 PN
CPU 1513F-1 PN iuniscit executionem programmatum normalium et fall-safe cum memoria programmatum 450 KB, memoria datorum 1.5 MB, et interfacie PROFINET IRT biportuali.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7513-1FL01-0AB0 |
| Typus Producti | Fail-safe programmable logic controller CPU |
| Functio principalis | Executat programmmata automationis normalia et fall-safe cum communicatione PROFINET integrata |
| Applicatio vel series compatibiles | Systemata SIMATIC S7-1500 quae unum CPU fall-safe et interfaciem PROFINET IRT biportalem requirunt |
Identificatio exacta.
Confer characterem ad characterem 6ES7513-1FL01-0AB0 et confirmat designationem integram SIMATIC S7-1500F CPU 1513F-1 PN.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
CPU 1513F-1 PN iuniscit executionem programmatum normalium et fall-safe cum memoria programmatum 450 KB, memoria datorum 1.5 MB, et interfacie PROFINET IRT biportuali.
Adiuvat applicationes securitatis usque ad niveles SIL 3 et PL e documentatos. Interruptor biportualis praebet interfaciem communicationis CPU pro retibus PROFINET. Tempora instructionum publicata adiuvant officia controlis S7-1500 deterministica.
Key Functions
Processus Salutaris
Supportat applicationes securitatis usque ad niveles SIL 3 et PL e documentatos.
PROFINET integratum
Interruptor biportus praebet interfaciem communicationis CPU pro retibus PROFINET.
Celeris programmatum executionis
Tempora instructionum publicata supportant certas functiones controllo S7-1500.
Official Specifications
| Versio Firmamentalis | V2.9 |
|---|---|
| Memoria operativa pro programma | 450 KB |
| Memoria operativa pro datis | 1.5 MB |
| Memoria Onus | Requiritur carta memoriae SIMATIC, usque ad 32 GB |
| PROFINET Interfaciis | 1 |
| Portus PROFINET | interruptor biportus |
| PROFINET Real-Time | RT et IRT |
| Tempus Operationis Bit | 40 ns |
| Tempus Operationis Verbi | 48 ns |
| Tempus Operationis Puncti Fixi | 64 ns |
| Tempus Operationis Puncti Fluctuantis | 256 ns |
| Rated Supply | 24 V DC |
| AMPLITUDO ADMISSIBILIS FONDIS | 19,2 ad 28,8 V CC |
| Perditio potentiæ typica | 5.7 W |
| Dimensiones | 35 × 147 × 129 mm |
| Pondus | Circa 430 g |
| Integritas Securitatis | Usque ad SIL 3 / PL e |
Quaestiones Frequenter Rogatae
Quae editio ingenieriae suadet firmam versionem V2.9 in 6ES7513-1FL01-0AB0?
Utere TIA Portal V17 aut posteriore editione quae versionem firmam electam suadet.
Num 6ES7513-1FL01-0AB0 cardinam memoriae requirit?
Ita; insere approbatam SIMATIC Memory Card antequam in operationem mittatur.
Quot portus PROFINET in 6ES7513-1FL01-0AB0 integrati sunt?
Interfacs integrata utitur commutatore duorum portuum.
Num 6ES7513-1FL01-0AB0 programmate fall-safe exsequi potest?
Yes; configure the safety project and complete the required acceptance process.
What should be copied before replacing 6ES7513-1FL01-0AB0?
Preserve the TIA Portal project, safety signature, device name, IP settings and memory-card contents.
What supply is required for 6ES7513-1FL01-0AB0?
Praebere 24 V DC intra intervallum specificatum 19,2 ad 28,8 V.
What must be verified after replacing 6ES7513-1FL01-0AB0?
Check firmware compatibility, hardware configuration, PROFINET topology, diagnostics and the authorized safety acceptance test.
Compatibility & Ordering Notes
Index Compatibilitatis
- Use a TIA Portal version that supports the selected firmware.
- Preserve the complete standard and fail-safe project with its safety signature.
- Match the memory card, device name, IP settings and PROFINET topology.