Siemens SIMATIC S7-400 6ES7416-3ER05-0AB0 CPU 416-3 PN/DP

Fabricator: Siemens
Status: Novissimum
Tempus Expectatus: In Stoc
Origo: Germania
Praestatio: 12 menses

  • Praevisio
  • Productum Overview
  • Functiones Principales
  • Official Specifications
  • FREQUENTLY ASKED QUESTIONS
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Pròdòt ràccumandà
Praevisio
Siemens SIMATIC S7-400 • CPU 416-3 PN/DP

6ES7416-3ER05-0AB0 CPU 416-3 PN/DP

Siemens 6ES7416-3ER05-0AB0 is a SIMATIC S7-400 CPU 416-3 PN/DP with firmware V5.3, 11.2 MB work memory, MPI/DP, PROFIBUS DP and integrated PROFINET communication.

At a Glance

Nomen commerciale / Fabricator Siemens
Model / Article Number 6ES7416-3ER05-0AB0
Product Type SIMATIC S7-400 CPU 416-3 PN/DP Central Processing Unit
Functio principalis Executes S7-400 control programs with MPI/DP, PROFIBUS DP and integrated PROFINET communication
Application / Compatible Series Modular SIMATIC S7-400 automation systems

Identificatio exacta.

Match the complete article number, photographed nameplate and firmware level before replacement.

Arrangementum Interfacis

Confirmare MPI/DP, PROFIBUS DP, Ethernet/PROFINET et coniunctiones IF 964-DP optativas ab projectu installato usurpatas.

Configuration Check

Verificare catalogum hardware STEP 7, cartam memoriae, positionem rae duorum locorum, attributionem et nomina dispositivorum PROFINET antequam in operationem mittatur.

Productum Overview

6ES7416-3ER05-0AB0 est unitas centralis processus Siemens SIMATIC S7-400 CPU 416-3 PN/DP cum memoria operativa integrata 11,2 MB. Unit MPI/DP, PROFIBUS DP et communicationem Ethernet/PROFINET integratam pro systematibus automationis modularibus S7-400.

Siemens praescribit firmam V5.3 et STEP 7 V5.4 SP4 cum actualizatione hardware applicabili ad configurationem. Interficies Ethernet integrata includit interruptorem RJ45 biiugum pro PROFINET IO, dum modulus insertilis IF 964-DP potest praebere ulteriorem interfaciem DP.

Focus ordinandi: confirmare numerum articuli completum, firmam installatam et configurationem hardware, typum cartae memoriae, allocationem rae, servosum projecti et parametres rete antequam substituatur aut in operationem mittatur.
Functiones Principales

Elaboratio et Memoria

Exequitur operationes bit, verbum et puncti fixi in 30 ns et operationes puncti fluitantis in 90 ns, cum memoria operativa integrata 11,2 MB divisa aequo inter codicem et datos.

Interreticulatio Industrialis

Combinat communicationem MPI/DP usque ad 12 Mbps cum interfacie Ethernet biiportu integrata pro PROFINET IO, communicatione S7, directione et communicatione aperta IE.

Expansiones et Diagnostica S7-400

Sustinet unum cuneum centralem cum usque ad 21 unitatibus expansionis, aliam interfaciem DP per IF 964-DP, et tamponem diagnosticum programmabilem cum usque ad 3200 intrationibus.

Official Specifications
Versio Firmamentalis V5.3
Memoria operativa 11,2 MB totalis (5,6 MB pro codice et 5,6 MB pro datis)
Integrated load memory 1024 KB RAM
Memoria de Carga Expandible Cardina FLASH usque ad 64 MB; cardina RAM usque ad 64 MB
Tempus Exsecutionis pro Operationibus Bit, Verbi et Puncti Fixi 30 ns
Tempus Operationis Puncti Fluctuantis 90 ns
Numerus S7 Contra et Temporizatores Disponibiles 2048 contra et 2048 temporizatores
Totalis I/O-Adressarea 16 KB inpuut / 16 KB outpuut
Capacitas expansionis rack 1 rack centralis cum usque ad 21 unitatibus expansionis
Interfacs Ethernet / PROFINET Interruptor bipoertus integratus; 2 × RJ45; 10/100 Mbps autosensibilis
Dispositiva PROFINET IO Maximum 256
Servos PROFIBUS DP Maximum 125
Dimensiones montandi (L × A × P) 50 × 290 × 219 mm
Fissurae Requisitae 2
Pondus Approximatum 0,9 kg
S7-400 Backplane Current at 5 V DC 1.2 A typice; 1.4 A maxime
Ammissio Potentiae 6.0 W typical

Fons officialis: Siemens SIMATIC S7-400 CPU Specifications, section 10.8 for 6ES7416-3ER05-0AB0 . Stockus commercialis, garantia et affirmationes de expeditione sunt conditiones venditoris.

FREQUENTLY ASKED QUESTIONS

Which STEP 7 version is required to configure 6ES7416-3ER05-0AB0?

Siemens specifies STEP 7 V5.4 SP4 or later with the relevant hardware update for firmware V5.3.

How much work and load memory does 6ES7416-3ER05-0AB0 provide?

The CPU provides 11.2 MB integrated work memory, divided into 5.6 MB for code and 5.6 MB for data. It also has 1024 KB integrated RAM load memory and supports FLASH or RAM memory cards up to 64 MB.

Which communication interfaces are available on 6ES7416-3ER05-0AB0?

The first interface supports MPI/DP at up to 12 Mbps. The integrated Ethernet interface uses a two-port switch with two RJ45 sockets and supports PROFINET IO; an IF 964-DP module can provide the additional DP interface.

How much rack space is needed for 6ES7416-3ER05-0AB0?

Dimensiones de montaje: 50 × 290 × 219 mm; la CPU ocupa dos ranuras S7-400.

¿Cuántos dispositivos PROFINET IO puede controlar el modelo 6ES7416-3ER05-0AB0?

El controlador PROFINET IO integrado admite hasta 256 dispositivos PROFINET IO, sujeto al área de direcciones configurada, al número de submódulos y a los requisitos de tiempo de actualización.

¿Qué debe verificarse antes de reemplazar el modelo 6ES7416-3ER05-0AB0?

Verifique el número de pedido completo, el nivel de hardware y firmware de la CPU, la configuración de hardware STEP 7, el tipo de tarjeta de memoria, la asignación del bastidor, los ajustes MPI/DP, las direcciones PROFIBUS y los nombres de los dispositivos PROFINET antes de poner en servicio el reemplazo.

¿Qué capacidad de diagnóstico ofrece el modelo 6ES7416-3ER05-0AB0?

La CPU dispone de un buffer de diagnóstico programable con hasta 3200 entradas, configurado por defecto con 120 entradas, y soporta funciones de estado/modificación para puesta en servicio y resolución de problemas.

Compatibility & Ordering Notes
Antes de pedir el modelo 6ES7416-3ER05-0AB0: asegúrese de que coincida el número de artículo completo de Siemens y verifique el hardware S7-400 instalado, el firmware y los datos del proyecto.

Compatibility Checklist for 6ES7416-3ER05-0AB0

  • Confirm that the rack provides two slots and that the cabinet power budget supports the specified S7-400 backplane current.
  • Use STEP 7 V5.4 SP4 or later with the applicable hardware update when engineering firmware V5.3.
  • Check whether the installed project uses a FLASH or RAM memory card and preserve the program and configuration before replacement work.
  • Record MPI/DP and PROFIBUS addresses, PROFINET device names, IP settings, configured IO devices and any IF 964-DP module before removal.
  • Verify connector allocation, network topology and the configured I/O address areas before applying power to a replacement CPU.
  • Do not treat a later CPU 416-3 PN/DP revision as a drop-in substitute until its firmware, memory, interfaces and STEP 7 hardware configuration have been checked against the existing project.
Hot Selling Models
MS-RA70N
MTN646991 REG-K 0-10V
IM1-12EX-T
Merten 670802
Ms-combo-1
Lenel 110220001
MTN565219
ABB CP-D12/2.1
ABB 1SD A054910
140DDI35310
CS-LC02
L5504D2A
7030.2
T2500
Nucps-hk / 1b

Obtain a Free Quote

Our representative will contact you shortly.
Email
Nomen
Nomen societatis
Notula
0/1000
email ireAdSummum

Evolo Automation non est distributor autorizatus, nisi aliter specificatum, representativus vel affinis fabricantis huius producti. Omnia nomina commercialia et documenta proprietatis sunt suorum dominorum respective et praebentur ad identificationem et informationem.