Siemens SIMATIC S7-400F CPU 416F-2 6ES7416-2FK04-0AB0
Fabricator: Siemens
Status: Novissimum
Tempus Expectatus: In Stoc
Origo: Germania
Praestatio: 12 menses
Email: [email protected]
whatsapp: +86-18150117685
- Praevisio
- Productum Overview
- Functiones Principales
- Official Specifications
- FREQUENTLY ASKED QUESTIONS
- Compatibility & Ordering Notes
- Hot Selling Models
- Pròdòt ràccumandà
Praevisio
SIEMENS SIMATIC S7-400F — fail-safe programmable logic controller CPU
6ES7416-2FK04-0AB0 SIMATIC S7-400F CPU 416F-2
Siemens specifies the CPU 416F-2 as a fail-safe S7-400 processor with separate 1.4 MB code and data memories, MPI/DP and PROFIBUS DP communication.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7416-2FK04-0AB0 |
| Product Type | fail-safe programmable logic controller CPU |
| Functio principalis | Runs standard and fail-safe S7-400 control programs with dual PROFIBUS-capable interfaces |
| Applicatio vel series compatibiles | Safety-related SIMATIC S7-400F automation and distributed I/O systems |
Productum Overview
Siemens specifies the CPU 416F-2 as a fail-safe S7-400 processor with separate 1.4 MB code and data memories, MPI/DP and PROFIBUS DP communication.
Documentatio officialis Siemens identificat productum pro systematibus automationis SIMATIC S7-400F ad securitatem pertinentibus et systematibus I/O distributis. Selectio et commissio sequi debent valores electricos, de interface, de memoria, ambientales et mechanicus infra monstratos, qui sunt documentati.
Functiones Principales
Elaboratio Failsafe
F-CPU sustinet automationem ad securitatem pertinentem una cum operibus controllo normalibus.
Accessus duplex ad campum bus
Interfaces MPI/DP et PROFIBUS DP integratae connectunt systemata centralia et distributa.
Memoria de Carga Expandible
Cartae memoriae FLASH vel RAM praebent usque ad 64 MB memoriae oneris.
Official Specifications
| Versio Firmamentalis | V4.0.0 |
|---|---|
| Software Ingeniorium | STEP 7 V5.2 SP1 HF3 cum actualisatione hardware vel posterior |
| Memoria operativa | 1,4 MB codicis et 1,4 MB dati |
| Memoria Integra Onus | 256 KB |
| Capacitas Cartae Memoriae | Usque ad 64 MB FLASH vel RAM |
| Pugna tergum | Omnia data salvare possunt |
| Tempus operationis bit / verbum / puncti fixi | 0,04 µs singula |
| Tempus Operationis Puncti Fluctuantis | 0.12 µs |
| S7 numeratores / temporizatores | 2 048 utrumque |
| Indicatores memoriae | 16 kB |
| Blocchi dati | Maximum 4 095; 64 KB singula |
| Vietējie dati | Maximum 32 KB |
| Bloca Functionum / Functiones | Maximum 2 048 singula; 64 KB |
| Totalis I/O-Adressarea | 16 KB inpuut / 16 KB outpuut |
| Default Process Image | 512 bytes ad ingressus / 512 bytes ad egressus |
| Imago Processus adiustabilis | Usque ad 16 KB ad ingressus / 16 KB ad egressus |
| Imāginēs Processūs Partiālēs | 15 |
| Canalis digitalis / analogici | 131.072 pro singulo / 8.192 pro singulo |
FREQUENTLY ASKED QUESTIONS
Num 6ES7416-2FK04-0AB0 ad controllum rei salutis destinatur?
Ita est. Est CPU fallax quae functiones salutis et automationis normales exequi potest.
Quomodo memoria operativa in 6ES7416-2FK04-0AB0 dividitur?
Areae separatae 1,4 MB pro codice programma et datis disponibiles sunt.
Quae conexiones fieldbus in 6ES7416-2FK04-0AB0 integratae sunt?
CPU interfacium MPI/DP et interfacium PROFIBUS DP additivum praebet.
Quae expansio memoriae oneris cum 6ES7416-2FK04-0AB0 uti potest?
Cartae FLASH vel RAM usque ad capacitatem 64 MB suportantur.
Quam cito instructiones basilares in 6ES7416-2FK04-0AB0 exeunt?
Operationes bit, word et puncti-fixi 0,04 µs occupant, dum operationes puncti-fluentis 0,12 µs occupant.
Quantam processus I/O 6ES7416-2FK04-0AB0 adhibere potest?
Area totalis adressandi est 16 KB pro intratis et 16 KB pro extratis.
Quale baseline ingegneristica deve essere disponibile per 6ES7416-2FK04-0AB0?
Usare STEP 7 V5.2 SP1 HF3 con l’aggiornamento hardware richiesto oppure una configurazione successiva supportata.
Compatibility & Ordering Notes
Elenco di compatibilità per 6ES7416-2FK04-0AB0
- Confrontare carattere per carattere il CPU SIMATIC S7-400F 416F-2 e il numero articolo completo.
- Verificare il software di ingegnerizzazione: STEP 7 V5.2 SP1 HF3 con aggiornamento hardware oppure versione successiva.
- Confermare il backup a batteria: tutti i dati possono essere salvati.
- Conservare le impostazioni approvate e i registri delle connessioni utilizzati nei sistemi di automazione Safety-related SIMATIC S7-400F e negli I/O distribuiti.