Siemens SIMATIC S7-400 CPU 414-2 6ES7414-2XG03-0AB0

Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Product Overview
  • Key Functions
  • Official Specifications
  • Quaestiones Frequenter Rogatae
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Producta commendata
Conspectus

Siemens • SIMATIC S7-400

6ES7414-2XG03-0AB0 SIMATIC S7-400 CPU 414-2

SIMATIC S7-400 CPU 414-2 praebet 256 KB memoriae operativae integratae, duas interfacies MPI/PROFIBUS DP integratas et subsidium expansionis pro systematibus automationis modularibus.

Ad Primum Aspectum

Nota Siemens
Modellum 6ES7414-2XG03-0AB0
Typus Producti CPU controlleris programmabilis modularis
Functio principalis Executes S7-400 control programs and manages integrated MPI/PROFIBUS DP communication
Applicatio vel series compatibiles SIMATIC S7-400 central racks with compatible STEP 7 projects, memory cards and distributed I/O

Identificatio exacta.

Match 6ES7414-2XG03-0AB0 character by character and confirm the complete SIMATIC S7-400 CPU 414-2 designation.

Arrangementum Interfacis

Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.

Configuration Check

Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.

Product Overview

SIMATIC S7-400 CPU 414-2 praebet 256 KB memoriae operativae integratae, duas interfacies MPI/PROFIBUS DP integratas et subsidium expansionis pro systematibus automationis modularibus.

The integrated 256 KB work memory is divided into 128 KB for code and 128 KB for data. Two integrated interfaces support MPI and PROFIBUS DP communication at rates up to 12 Mbit/s. Memory cards, expansion units and communication or function modules extend the controller for larger applications.

Focus ordinandi: Confirm the complete CPU article number, firmware and STEP 7 project, 256 KB memory requirement, memory card, rack slot, MPI/DP configuration and expansion layout.
Key Functions

Balanced Program and Data Memory

The integrated 256 KB work memory is divided into 128 KB for code and 128 KB for data.

Dual PROFIBUS-Capable Interfaces

Two integrated interfaces support MPI and PROFIBUS DP communication at rates up to 12 Mbit/s.

Expandable S7-400 Architecture

Cartae memoriae, unitates expansionis et moduli communicationis vel functionum controllerem ad applicationes maiorem extendunt.

Official Specifications
Tensio nominalis supplicii 24 V DC
Perditio potentiæ typica 7,5 W
Maxima currentis dorsalis 5 V 1.6 A
Memoria Laboris Integra 256 KB
Memoria programmandi 128 KB
Memoria Datorum 128 KB
Memoria Integra Onus 256 KB
Capacité maximale de la carte mémoire 64 MB
Interfacies MPI/PROFIBUS integratae 2
Maxima velocitas transmissionis MPI 12 Mbit/s
Coniunctiones MPI 32
Maximae coniunctiones PROFIBUS DP 16
Maximi servi DP integrati 32
Maxima area adressionis input DP 2 KB
Maxima area adressionis output DP 2 KB
Unitates Expansionis Maximum 21; inter quas usque ad 6 cum K-bus
Interstitia Armaturae Requiruntur 1
Horologium Mechanicum Retentivus et synchronizabilis
Quaestiones Frequenter Rogatae

Quod proiectum STEP 7 in 6ES7414-2XG03-0AB0 onerandum est?

Onlud only the archived project whose hardware configuration, firmware assumptions and network assignments match the installed station.

Can 6ES7414-2XG03-0AB0 act as a PROFIBUS DP master?

Yes; configure the intended integrated interface and restore the validated slave addresses and bus parameters.

What memory card should be used with 6ES7414-2XG03-0AB0?

Use a compatible S7-400 RAM or FLASH memory card sized for the approved program and load-memory requirement.

How many expansion units can 6ES7414-2XG03-0AB0 support?

The configured system may use up to 21 expansion units, subject to the published interface and K-bus limits.

What must be recorded before replacing 6ES7414-2XG03-0AB0?

Capture the firmware level, memory-card contents, rack position, MPI and DP addresses, retentive data and clock settings.

Can 6ES7414-2XG03-0AB0 share a rack with other CPUs?

Yes; multicomputing is supported in suitable UR1 or UR2 configurations with no more than four CPUs.

What checks are required after commissioning 6ES7414-2XG03-0AB0?

Verify RUN status, diagnostics, distributed I/O, communication links, time synchronization and the complete machine sequence.

Compatibility & Ordering Notes
Before ordering 6ES7414-2XG03-0AB0: Confirm the complete CPU article number, firmware and STEP 7 project, 256 KB memory requirement, memory card, rack slot, MPI/DP configuration and expansion layout.

Index Compatibilitatis

  • Match the installed S7-400 rack and power-supply design.
  • Restore both integrated interface configurations exactly.
  • Use the approved memory card and archived STEP 7 hardware configuration.
Hot Selling Models
ABB CA5-04N 1SBN010040R1204
PSU100C 6EP1331-5BA00
UT4-TWIN
3RP1505-1AP30
CPV18-DZP
CAB-438
V3S-GM
S401M-K6
1642 50 024 005
281-684 51129487
AZ1612ZVKM16
1669631
0305525
6SN1111-0AB00-0AA0
LFM-1/8-S

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.