Siemens 6ES7122-1BB00-0AA0 SIMATIC SC 2DO DC24V/0.5A Electronic Submodule
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Keep each output within its permitted current range.
- Respect the 0.8 A module limit at +60 °C.
- Do not use parallel outputs for redundant control.
- Use the specified short-circuit recovery procedure if restart fails.
6ES7122-1BB00-0AA0 SIMATIC SC 2DO DC24V/0.5A Electronic Submodule
A compact two-output 24 V DC submodule with electronic short-circuit protection and a nominal 0.5 A rating per channel.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7122-1BB00-0AA0 |
| Typus Producti | Digital output submodule |
| Functio principalis | Switching compact field actuators |
| Applicatio | SIMATIC SC TB16SC terminal blocks |
Two semiconductor outputs
Each output has a nominal 0.5 A ON-state rating.
Defined module derating
Summa duorum canalium est 1 A usque ad 40 °C et 0.8 A usque ad 60 °C.
Constructio SC ad inserendum
Submodulus electronicus convenit cum systemate terminalium TB16SC.
Product Overview
6ES7122-1BB00-0AA0 praebet duas digitales outputes 24 V DC in systemate terminalium SIMATIC Smart Connect.
Modulus angustus ad inserendum includit LEDs virides pro statu outputis et protectionem electronicam contra curtum circuitum, cum limitibus commutationis diversis pro oneribus resistivis, inductivis et lamparum.
Key Functions
Agitare onera DC compacta
Uterque ex duobus outputibus praebet commutationem nominalem 0.5 A pro circuitibus campi destinatis.
Limitare currentem curtis circuitus
Protectio electronicus outputis reagit ad limen typicum 0.7–1.8 A.
Supporta substitutio servitii SC
Submodulus in bloco terminali inseritur et usque ad viginti ciclos insertionis permittit.
Official Specifications
| Output Channel Count | 2 |
|---|---|
| Alimentatio oneris nominalis | 24 V DC |
| Rated current per output | 0,5 A |
| Current canalis in statu ON permittendus | 5 mA–0,6 A |
| Current totalis moduli maximalis | 1 A usque ad +40 °C; 0.8 A usque ad +60 °C |
| Maximum OFF-State Residual Current | 0.3 mA |
| Minima tensio outputi in statu ON | L+ minus 0.5 V |
| Currentia de supply sine onus maximum | 3 mA |
| Perdita de Potentia Typical del Modulo | 0.4 W |
| Tempus morae commutationis oneris resistivi | ON: usque ad 200 µs; OFF: usque ad 1.3 ms |
| Permitted Load Resistance | 48 Ω–4.8 kΩ |
| Maxima onus lampadis | 2.5 W |
| Rationes commutationis maximae | 100 Hz resistive; 2 Hz inductive at 0.3 A or 0.5 Hz at 0.5 A; 1 Hz lamp |
| Electronic short-circuit response threshold | Typically 0.7–1.8 A |
| Longitudo Maxima Cavi | 600 m non schermati; 1 000 m schermati |
| Insertion-cycle limit | 20 into a TB16SC |
| Isolatio Electrica | None between outputs or between outputs and SC bus |
| Dimensiones (L × H × D) | 10 × 64 × 51 mm |
| Approximate submodule weight | 15 g |
Quaestiones Frequenter Rogatae
Can both outputs of 6ES7122-1BB00-0AA0 carry 0.5 A continuously at 60 °C?
No, the module total current is limited to 0.8 A at 60 °C.
How should I restore an output of 6ES7122-1BB00-0AA0 after clearing a short circuit?
Si reinitiatio sub onere pleno deficit, signum output muta, tensionem moduli oneris interrumpa, aut onus temporarie disconecte.
Num commutatio mechanica L+ impulsum brevem in output 6ES7122-1BB00-0AA0 producere potest?
Ita, output impulsum transitorium circa 8 µs ad currentem nominalem, aut usque ad 20 µs ad onus 10 mA, producere potest, cum L+ mechanice commutatur.
Num 6ES7122-1BB00-0AA0 lampam 5 W in uno output ducere potest?
Non, onus maximum lampae est 2.5 W.
Num duo outputs 6ES7122-1BB00-0AA0 ab omnibus SC isolati sunt?
Non, nulla isolatio galvanica inter outputs et omnibus SC est.
Quotiens 6ES7122-1BB00-0AA0 in suum blocum terminalium TB16SC inseri potest?
Numerus insertionum permittarum maximus est viginti.
Num outputs 6ES7122-1BB00-0AA0 parallele coniungi possunt ad controllem redundatem unius oneris?
No, outputs may not be paralleled for redundant load control.