Siemens 3SF1324-1SD21-1BA1 SIRIUS ASIsafe Guard-Locking Position Switch
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Ordina actuatorem aptum ad geometriam accessus et motum custodis postulatas.
- Adaptato principium operationis resiliens ad conceptionem tutelae machinae.
- Utere AS-i wiring assignment et definita actuator/magnet channel mapping.
- Applica EN ISO 14119 locking-force rating dum aestimatur guard-locking requirement.
3SF1324-1SD21-1BA1 SIRIUS ASIsafe Guard-Locking Position Switch
A spring-locked position switch with integrated ASIsafe, five approach directions, an M12 connection and front auxiliary release.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 3SF1324-1SD21-1BA1 |
| Typus Producti | Safety position switch with guard locking |
| Functio principalis | Monitoring actuator and locking status |
| Applicatio | ASIsafe machine-guard circuits |
Spring-actuated guard lock
The closed-circuit locking arrangement uses a spring-applied lock with auxiliary release.
Separate status monitoring
ASIsafe channel 1 monitors an actuator NC contact and channel 2 monitors a magnet NC contact.
Flexible actuator approach
The head accommodates five approach directions with a separately selected actuator.
Product Overview
3SF1324-1SD21-1BA1 monitors the separate actuator and the guard-locking magnet through an integrated ASIsafe arrangement.
The plastic switch provides spring-actuated locking and a front auxiliary release; the appropriate separate actuator is selected for the door movement and mounting arrangement.
Key Functions
Spring-actuated guard lock
The closed-circuit locking arrangement uses a spring-applied lock with auxiliary release.
Separate status monitoring
ASIsafe channel 1 monitors an actuator NC contact and channel 2 monitors a magnet NC contact.
Flexible actuator approach
The head accommodates five approach directions with a separately selected actuator.
Official Specifications
| Locking-force values | 1,300 N locking force; 1,000 N rating according to EN ISO 14119 |
|---|---|
| Forza minima di attivazione | 30 N |
| Directiones adprobandae | 5 |
| Monitorium Contactuum | Actuator: 2 NC/1 NO; magnet: 2 NC/1 NO |
| Assignatio intrantis ASIsafe | Canalis 1: actuator, 1 NC; canalis 2: magnet, 1 NC |
| Mechanismus claudendi | Principium circuitus clausi actum a mola; liberatio auxiliaris anterior |
| Tensio magnetis | 24 V AC/DC |
| Nexus | Conector M12 fixus quadrupolaris |
| Assignatio pinarum M12 | Pinus 1 AS-i+; pinus 3 AS-i−; pini 2 et 4 non assignati |
| Tensionis insulatio evaluata | 30 V |
| Resistentia nominālis ad impulsum | 0,8 kV |
| Gradus Contaminations | 3 |
| Vita mecanica typica | 1.000.000 ciclos de operatione |
| Accurate repetere | 0,1 mm |
| Resistentia ad ictum | 30 g pro 11 ms |
| Resistentia vibrationibus | 0.35 mm / 5 g |
| Ambiens Operativa | −25 usque ad +60 °C |
| Ambiens depositi | −40 ad +80 °C |
| Constructio et Montatio | Plastic housing and head; screw fixing; any mounting position |
| Massa neta | 0.509 kg |
Quaestiones Frequenter Rogatae
Is a separate actuator included with 3SF1324-1SD21-1BA1?
The matching actuator must be ordered separately.
Which parts are monitored by the two ASIsafe channels of 3SF1324-1SD21-1BA1?
Channel 1 monitors an actuator NC contact and channel 2 monitors a magnet NC contact.
Does 3SF1324-1SD21-1BA1 require an additional external 24 V supply?
No additional 24 V supply is required for this integrated ASIsafe version.
Which M12 pins carry the AS-i bus on 3SF1324-1SD21-1BA1?
Pinus 1 portat AS-i positivus et pinus 3 portat AS-i negativus.
Ubi liberatio auxiliaris sita est in 3SF1324-1SD21-1BA1?
Liberatio auxiliaris est in parte anteriori interruptoris.
Quam valorem fortitudinis clausurae uti debes pro 3SF1324-1SD21-1BA1 secundum EN ISO 14119?
Valor fortitudinis clausurae secundum EN ISO 14119 est 1 000 N.
Potestne 3SF1324-1SD21-1BA1 in diversis positionibus montari?
Interruptor permittit omnem positionem montandi.