Conspectus
- Elige unum ex septem intervallis temporis ante impactionem temporis definitam.
- Usus contactus commutativi unici post tempus pro functione circuitus regendi quaesita.
- Intervallo recuperationis 250 ms concedendum est cum cycli temporales repetiti designantur.
- Circuitum interruptivum protege fusibilibus gL/gG 4 A et torque terminale specificatum serva.
3RP2525-1AW30 SIRIUS 3RP25 On-Delay Timing Relay
An on-delay timer with seven ranges from 0.05 s to 100 h, one changeover contact and a 17.5 mm housing.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 3RP2525-1AW30 |
| Typus Producti | Electronic timing relay |
| Functio principalis | Delaying control-circuit switching |
| Applicatio | Timed machine start sequences |
Cover short and long delays
Seven time ranges span 0.05 seconds to 100 hours.
Switch a changeover circuit
One delayed changeover contact provides the relay output.
Use a compact panel footprint
The 17.5 mm enclosure accepts a wide-range AC/DC supply and supports DIN-rail or screw mounting.
Product Overview
3RP2525-1AW30 introduces an adjustable on-delay into an industrial control sequence.
Seven selectable timing ranges cover short switching delays through long-duration timing, while a single changeover contact provides the output interface.
Key Functions
Cover short and long delays
Seven time ranges span 0.05 seconds to 100 hours.
Switch a changeover circuit
One delayed changeover contact provides the relay output.
Use a compact panel footprint
The 17.5 mm enclosure accepts a wide-range AC/DC supply and supports DIN-rail or screw mounting.
Official Specifications
| Timing Span | 0.05 s to 100 h across 7 ranges |
|---|---|
| Control Supply | 12–240 V CA a 50/60 Hz oppure 12–240 V CC |
| Factor Operativus Supplicationis | 0,8–1,1 vicibus tensionis nominalis |
| Dispositio Exitus | 1 delayed changeover contact |
| Accuratio Configurationis | ±5% valoris pleni scalae |
| Accurate repetere | ±1% |
| Tempus Recuperationis | 250 ms |
| Influentia temperaturae | 1% of the set runtime over the temperature range |
| Supply Influence | 1% of the set runtime over the voltage range |
| Maxima Pēnsum Perditiōnis | 2 W |
| Currentus Contactus Thermalis | 5 A |
| AC-15 operational current | 3 A ad 24 V AC et 250 V AC |
| Corrente operativa DC-13 | 1 A ad 24 V DC; 0,2 A ad 125 V DC; 0,1 A ad 250 V DC |
| Fusibilis Requisitus pro Curtocircuito Contactus | 4 A gL/gG |
| Mecanicus Patiens | 10 milioane de cicluri de funcționare tipice |
| Tutela anterior | IP20 |
| Par de torsion pro terminalibus | 0,6–0,8 N·m |
| Temperatura operativa | −25 usque ad +60 °C |
| Dimensiones (L × H × D) | 17.5 × 100 × 90 mm |
| Ponderis netum | 0.133 kg |
Quaestiones Frequenter Rogatae
Can 3RP2525-1AW30 handle both a short machine delay and a delay lasting several hours?
The seven selectable ranges cover delays from 0.05 seconds to 100 hours.
Does 3RP2525-1AW30 retain an accumulated delay when power is removed?
The timer does not provide a non-volatile timing function.
How soon can 3RP2525-1AW30 recover after the timing supply is interrupted?
The specified recovery time is 250 ms.
How should I allow for the dial-setting tolerance of 3RP2525-1AW30?
The relative setting accuracy is ±5% of the selected full-scale value.
What repeatability can I expect from 3RP2525-1AW30 under the specified conditions?
Accuratio repetitio relativa est ±1%.
Num 3RP2525-1AW30 sequentiam fulguris repetitivam producere potest?
Haec versio operationem post tempus praebet et functionem fulguris non praebet.
Quomodo 3RP2525-1AW30 in tabulam DIN-rail densissime dispositam convenit?
Corpus 17,5 mm latitudinis raele occupat et montagium adhaesivum in raile DIN 35 mm sustinet.